Home Companies Kingsine Electric Automation Co., Ltd.

PMC96S 3 Phase Multifunction Energy Meter Intelligent RS485 Port

Kingsine Electric Automation Co., Ltd.

Contact Us

Trade Verify

Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China

Phone: 86-00852-23892981

Contact name:Amy

Inquir Now

Kingsine Electric Automation Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PMC96S 3 Phase Multifunction Energy Meter Intelligent RS485 Port

City & Province shenzhen guangdong
Categories Other Electric Power Tools
InquireNow

Product Details

PMC96S meter is a multi-functional power monitoring meter, it combines function of collecting data and control, and it can replace many kind of meters, relays, transformers and others components. PMC96S can be installed in different positions of electricity distribution system.
PMC96S is designed with RS-485 communication interface, which enable itself to be integrated into a variety of power monitoring systems. Data acquisition and remote control can be easily performed through the supporting management software or other industrial configuration software.

 

PMC96S is a true RMS-based measuring meter that can accurately measure highly nonlinear loads. Its advanced grid frequency synchronization sampling technology enables it to accurately measure a variety of power parameters, including voltage/current RMS, frequency, active power, reactive power, apparent power, power factor, input/output active energy, total active energy, Input/output reactive power, total reactive power, apparent power, voltage total harmonic distortion (THD), 1~31 voltage harmonics, current total harmonic distortion (THD) and 1~31 current harmonics, etc. . All measurements, min and max, and demand measurements can be viewed on the display or remotely using the software.

Overview of Meter functions

Table 1

Host function and characteristic
Transient true RMS value
Current Each single phase and combined phase, average value
Phase voltage/Line voltage Each single phase and combined phase, average value
Active, reactive, apparent power Sum of each single-phase and three-phase
Power factor Sum of each single-phase and three-phase
Frequency 45~65Hz
MIN/MAX VALUE
MIN/MAX CURRENT RMS
Maximum/minimum phase voltage RMS
Maximum/minimum total active, reactive, apparent power
Max/Min total power factor
Max/Min Frequency
Max/Min THD I和THD U
Demand and peak value
Current per phase the present value/peak value/monthly peak value
Total active power, total reactive power, total apparent power
the present value/peak value/monthly peak value
Energy
Input/ output/ active electric energy 1 channel pulse output
Input output active electric energy 1 channel pulse output
Input/ output/ reactive electric energy 1 channel pulse output
active electric energy 1 channel pulse output
apparent power
monthly energy
Electric energy multi-rate
8 multi-rate time, 4 rates can be set
Power quality
THD current and voltage
1-31 times harmonic analysis
Voltage crest factor CF and current K factor
Event record
100pcs SOE event record
Warning alarm system
8 warning channels with configurable limit value
4 warning channels with configurable logic
Communication
RS-485 /MODBUS-RTU Protocol
Display
Large screen STN liquid display
Real time clock
Year, month, date, minute, second
Others
Support program online upgrade

Table 2

Auxiliary module features
Analog I/O (DI) input module (optional)
2-channel Analog I/O input
Relay (DO) output module (optional)
2-channel relay output, which can be set by local over-limit alarm or by remote control
Analog input (AI)/output (AO) module (optional)
2 Channels in total
Being optional for 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output
The first analog port (A1 port) is located at the same (DI) port of Binary Input, so user only can select either one of the two but can’t select both

 

 

Technical indicators

Electrical characteristics
Measure type3P3W AC system,
3P4W AC system;
Samping rate128 points per cycle
Data refresh rate1S
Measure
accuracy
Cureen±0.2%FS
Voltage±0.2%FS
Power0.5S
Frequency±0.001Hz
Active Energy0.5S
Reactive Energy1.0S
DC input(AI)0.5% FS
DC output(AO)0.5% FS
Input voltage
characteristics
Measure Voltage3 *220/380V(Directly input)
3 * 57.7/100V(PT secondary side)
Allowed overload
capability
1.2times / continuous
input resistance300KΩ/phase
Input current characteristicsMeasure
current
5A (CT Secondary side)Or 1A (CT Secondaryside)
Allowed overload capability1.2 times/continuous
input resistance<0.1Ω
Binary inputWorking
voltage
15 VDC
input resistance12KΩ
Isolation voltage2KV
Relay OutputNode typeMechanical contact
Node capability220 VAC/5A,30 VDC/5A
4-20mA DC
input measurement
Measure current4-20mA
Allowed overload
capability
1.2 times / continuous
input resistance10Ω
Isolation
voltage
2KV
0-5V DC input measurementMeasure Voltage0-5V
Allowed overload
capability
1.2times / continuous
input resistance12.5KΩ
Isolation voltage2KV
4-20mA DC
output
Open-circuit Voltage15VDC
Load capability≤600Ω
Isolation voltage2KV
Power supplyAC85~264 VAC/45-65Hz
DC100~375 VDC
Power consumption< 3W
Mechanical performance
Weight0.5kg
IP Protection LevelMeter Panel IP52,Meter Host IP30
DimensionHost96 X 96 X 72 mm
Host+modules96 X 96 X 120 mm
Working temperatureDisplay screen-20~70℃
Meter-25~70℃
Storage temperatureMeter+display screen-40~85℃
Relative humidity5% - 90%RH, No condensation
EMC
Antistatic discharge interferenceIEC 61000-4-2,Level 4
Anti-fast transient group pulseIEC 61000-4-4,Level 4
Anti-surgeIEC 61000-4-5,Level 3
Resistance to power frequency magnetic fieldIEC 61000-4-8,Level 3
Electrical insulation performance
Insulation resistanceGB/T13729,>50MΩ
Power frequency withstand VoltageGB/T13729,AC 3KV 50Hz /1min
Impulse voltageGB/T13729,5KV,1.2/50us
PMC96S selection guide
Model specification::PMC96S-①-②-③-④-⑤
① Model code:
157.7/100V Rated measurement voltage,5A Rated measurement current.
257.7/100V Rated measurement voltage,1A Rated measurement current.
3220/380V Rated measurement voltage,5A Rated measurement current.
4220/380V Rated measurement voltage,1A Rated measurement current.
② Model code:
1Power supply:85~264 VAC/45-65Hz,100~300 VDC .
③ Model code:
0Without DI
22 Channels DI
④ Model code:
0Without relay output
1Optional 1 channel relay output(RL1+,RL1- port)
2Optional 2 channels relay output
⑤ Model code:
abab is a 2 integer,a means AI01 port optional for AI/AO modules, b means AI02portoptional for AI/AO
0 –none
1 - 0-5V DC analog input measure(AI)
2 - 4-20mA DC analog input measure(AI)
3 - 4-20mA DC analog output(AO)
For example:ab = 00,meansnot equipped with AI/AOmodule
ab = 21,Means AI01 port is equipped with 0-5V DC analog input measureAI/AOmodule, AI02 port is equipped with 4-20mA DC analog input measureAI/AOmodule

Hot Products

Description of K3163i Intelligent Protection Relay Test Set Kingsine K3163i has Integrated design, ...
(Recently shipped to the US of KF86 equipment, accessories and calibration certificate) Description ...
The world's lightest & high power universal relay test set 6x35A@425VA max & 6x310V@105VA max analog ...
High Power Protection Relay Testing IEC61850 KF86P 6x35A& 6x310V​ (Recently shipped to the US of ...
The Revolutionary High-power, High-precision, Multi-functional, Mini relay tester KFA310 has been ...
The world's lightest & high power universal relay test set ● 6x35A@425VA max & 6x310V@105VA max ...