Introduction
Ultrasonic flow thermal module/RTU be used in sundry liquids , support measure online
long-term.
Host install by lead rail, sensor be installed on outside of pipe
wall. Host contact the sensor use the cable
for ultrasonic sensor, can realize measure flow, if contact the
temperature sensor, can realize quantity measure.
It can be used in flow and quantity of heat, like, system integration, water resource, practice thrift energy,
drainage, heating power.
Feature
Parts
Parameters in detail |
Host part | Theory | Ultrasonic time gap. |
accuracy | ±1% |
Option method | 4-key keyboard support magnetic rod operation |
Signal output | 1channel 4~20mA at 0.1%current loop back, the maxim load resistor up to 1000ohm, |
1 channel OCT pulse output (default pulse width is 200ms, and can be
modify between 6 to 1000ms) |
1channel relay output(3A at 220V) |
signal input | 3 channel 4-20mA current loop back at 0.1%
circuit used to collect Temp. Pressure and liquid
level etc. . |
1 channel mV input use to pt100 for calorimeter |
Digital port | Rs485 support Mod-bus protocol and support firmware update |
Cable | special cable for Rs485 the range up to 1000m |
Suit pipe | Pipe material | steel, cast iron cement, copper, PVC, Aluminum, glass, etc. |
Inner DN. | 15~6000mm |
Sensor position | It's better the sensor fix at the
position of at least 10D far away of upstream,
or 5D far away of downstream at least 30D far away from the p ump outlet(D is the inner diameter of the pipe). |
Suit flow | media | water, sea water, waster water, liquid alcohol, beer,
gas, oil etc.. |
Temperature | -30~160℃ |
Turbidity | 10000ppm not so much bubbles |
Flow speed | 0~±10m/s |
Environment | Temperature | Host:-20 ~60℃; sensor:-30 ~160℃ |
Humidity | host:85 |