The full name of independent smoke detector is independent
photoelectric smoke detector, referred to as independent smoke
detector or independent smoke detector, which is one of the smoke
alarm series products. The alarm adopts optical smoke inductive
device and excellent production technology, stable work, beautiful
appearance, simple installation, no need to debug, can be widely
used in hotels, stores, Internet cafes, dance halls, cafes, leisure
halls, residential and other places for fire safety monitoring.
Working principle:
- The independent photoelectric smoke detector adopts the
photoelectric sensor with special structure design and SMD chip
processing technology. It has the characteristics of high
sensitivity, stable and reliable, low power consumption, beautiful
and durable, and easy to use. The circuit and power supply can be
self-checked and can be simulated alarm test.
The detector built-in emission tube, that is, a light-emitting
element and a photosensitive element, the light emitted by the
usual light source, through the lens to the photosensitive element,
the circuit is maintained normal, if there is smoke from the block,
the light on the photosensitive element is significantly weakened,
so the photosensitive element will change the light intensity into
an electrical change, through the amplifier circuit to alarm
people.
Technical Parameters:
Standards | EN 14604:2005/AC:2008/AS 3786:2014 | Power Supply | DC 9V Battery Operated | Sensor Type | Photoelectric | Sound Pressure | Loud>85dB(A)Alarm Signal(3M) | Flash Alarm Indicator(Red LED) | Flash Alarm Indicator(Red LED) | Button | Test Button | Low Battery Warning | √ | Replaceable Battery 1Y/3Y/5Y | √ | N.W. | ≈126g (Include Battery) | Dimensions | Φ100×36.7mm |
| |
---|
Product picture:
Installation specification:
Drill two mounting holes of 6mm diameter 60mm apart on the ceiling,
secure the detector base using plastic expansion tubes and screws,
and fasten the detector to the battery. Fasten the detector on the
base in the correct direction and tighten it clockwise after
pressing down.
Matters needing attention:
Independent smoke sensor should not be installed in the following
places:
Places where smoke is normally trapped
There are large dust, water mist, steam, oil mist pollution,
corrosive gas places
Places with relative humidity greater than 95%