Liquid Epoxy Resin Electrical Epoxy Resin 100pbw Double Components Adhesives

MSDS:

Strong adhesion                         Characteristics

Good insulation

Good process performance

Good surface gloss and electrical resistance

Excellent moisture resistance

 

1. IDENTIFICATION

Commodity name: JT 8055B Modified dicarboxylic Anhydride

Company Name: HUBEI JIANGTE INSULATION COMPOSITE CO., LTD.

Add: Room219 Zhanghua Road(N), EDA Qianjiang City, Hubei Province, China

Tel:+86-728-6201068

Fax:+86-728-6202066

Zip code:433132

 

 

2. HAZARDS IDENTIFICATION

Risk of serious damage to eyes.

May cause sensitization by inhalation and skin contact.

 

 

3. COMPOSITON INFORMATION ON INGREDIENT

Chemical NameCAS No.Content(%)
Modified Methyl tetrahydrophthalic Anhydride26590-20-5>40.0 - <50.0%
Silica Flour14808-60-7>50.0 - <60.0%

 

 

4. FIRST AID MEASURES

A. Eye contact

- Do not rub your eyes.

- Immediately flush eyes with plenty of water for at least 15minutes and call a doctor/physician.

 

B. Skin contact

- Flush skin with plenty of water for at least 15minutes while removing contaminated clothing and shoes.

- Laundering enough contaminated clothing before reuse.

- Go to hospital immediately if symptoms(flare, irritate) occur.

- Wash thoroughly after handling.

 

C. Inhalation contact

- When exposed to large amounts of steam and mist, move to fresh air.

- Take specific treatment if needed.

 

D. Ingestion contact

- About whether I should induce vomiting. Take the advice of a doctor.

- Rinse your mouth with water immediately.

 

E. Delayed and immediate effects and also chronic effects from short and long term exposure

- Not available

 

F. Notes to physician

- Notify medical personnel of contaminated situations and have them take appropriate protective measures.

 

 

5. FIRE-FIGHTING MEASURES

A. Suitable (Unsuitable) extinguishing media

- Dry chemical, carbon dioxide, regular foam extinguishing agent, spray.

- Avoid use of water jet for extinguishing.

 

B. Specific hazards arising from the chemical

- Not available

 

C. Special protective actions for firefighters

- Notify your local firestation and inform the location of the fire and characteristics hazard.

- Using a unattended and water devices in case of large fire and leave alone to burn if you do not imperative.

- Avoid inhalation of materials or combustion by-products.

- Do not access if the tank on fire.

- Use appropriate extinguishing measure suitable for surrounding fire.

- Keep containers cool with water spray.

- Vapor or gas is burned at distant ignition sources can be spread quickly.

 

 

6. ACCIDENTAL RELEASE MEASURES

A. Personal precautions, protective equipment and emergency procedures

- Must work against the wind, let the upwind people to evacuate.

- Move container to safe area from the leak area.

- Remove all sources of ignition.

- Do not direct water at spill or source of leak.

- Avoid skin contact and inhalation.

 

B. Environmental precautions

- Prevent runoff and contact with waterways, drains or sewers.

- If large amounts have been spilled, inform the relevant authorities.

 

C. Methods and materials for containment and cleaning up

- Large spill : Stay upwind and keep out of low areas. Dike for later disposal.

- Notification to central government, local government. When emissions at least of the standard amount

- Dispose of waste in accordance with local regulation.

- Appropriate container for disposal of spilled material collected.

- Small leak: sand or other non-combustible material, please let use absorption.

- Wipe off the solvent.

- Dike for later disposal.

- Prevent the influx to waterways, sewers, basements or confined spaces.

 

 

7. HANDLING AND STORAGE

A. Precautions for safe handling

- Wash thoroughly after handling.

- Avoid direct physical contact.

- Avoid contact with incompatible materials.

- Refer to Engineering controls and personal protective equipment.

- Do not inhale the steam prolonged or repeated.

 

B. Conditions for safe storage, including any incompatibilities

- Do not use damaged containers.

- Do not apply direct heat.

- Save applicable laws and regulations.

- Avoid direct sunlight.

- Keep in the original container.

- Collected them in sealed containers.

- Do not eat, drink or smoke when using this product.

- Store away from water and sewer.

 

 

8. OPERATION DISPOSAL AND STORAGE

Note: closed/sealed operation, provide good natural ventilation condition. The operator must go through specialized training, strictly follow the operating rules. We suggest that the operating personnel wearing Self suction filtering type dust mask, and wearing protective chemical safety glasses.

Storage note: dry and ventilated

 

 

9. PHYSICAL AND CHEMICAL PROPERTIES

-Appearance 
a. AppearanceLiquid(Viscous liquid)
b. ColorNot available
OdorNot available
-Odor thresholdNot available
-PHNot available
-Melting point/Freezing pointunapplied (liquid in room temperature)
-Initial Boiling Point/Boiling RangesNot available
-Flash point>130℃(Estimated value)
-Evaporation rateNot available
-Flammability(solid, gas)Not available
-Upper/Lower Flammability or explosive limitsNot available
-Water SolubilityInsoluble (at 20℃)
-Specific gravity(Relative density)1.60-1.80g/cm3(at 25℃)
-Autoignition temperatureNot available
-Decomposition temperatureNot available
-Viscosity1000~4000mPa.s(at 40℃)

 

 

10. STABILITY AND REACTIVITY

A. Chemical Stability and Reactivity

- This material is stable under recommended storage and handling conditions.

 

B. Possibility of hazardous reactions

- Hazardous Polymerization will not occur.

 

C. Conditions to avoid

- Avoid contact with incompatible materials and condition.

- Avoid Accumulation of electrostatic charges, Heating, Flames and hot surfaces

 

D. Incompatible materials

- Not available

 

E. Hazardous decomposition products

- May emit flammable vapour if involved in fire.

 

 

11. TOXICOLOGICAL INFORMATION

Acute oral toxicity : LD50 rat

Dose: > 2,000 mg/kg, Method: calculated

 

Eye irritation : Risk of serious damage to eyes.

rabbit

Method: Data based on tests on similar product.

 

Skin irritation: No skin irritation

rabbit

Method: Data based on tests on similar product.

dermal

 

Sensitization: Causes sensitization. Guinea pig

Method: Data based on tests on similar product.

Dermal

 

 

 

12. ECOLOGICALINFORMATION

Ecotoxicity effects

 

Further information on ecology

Additional ecological : Avoid subsoil penetration.

information Prevent product from entering drains.

Do not contaminate surface water.

 

 

13. DISPOSAL CONSIDERATIONS

A. Disposal methods

- Since more than two kinds of designed waste is mixed, it is difficult to treat separately, then can be reduction or stabilization by incineration or similar process.

- If water separation is possible, pre-process with Water separation process.

- Dispose by incineration.

- Incinerate the oil by separating the oil and water

- The remainder of the water after separation will be processed in a water pollution prevention facilities.

- Do incineration or stabilization of the residue after disposal as the method of evaporation and concentration.

- Do incineration of the residue after disposal as the method of agglomeration and precipitation.

- Take care of incinerate or stabilization after treatment, purified by means of Separation distillation extraction filtration pyrolysis

 

B. Special precautions for disposal

- The user of this product must disposal by oneself or entrust to waste disposer or person who other’s waste recycle and dispose, person who establish and operate waste disposal facilities.

- Dispose of waste in accordance with all applicable laws and regulations.

 

 

14. TRANSPORT INFORMATION

A. UN No. (IMDG)

- Non Hazmat

 

B. Proper shipping name

- Non Hazmat

 

C. Hazard Class

- Non Hazmat

 

D. IMDG Packing group

- Non Hazmat

 

E. Marine pollutant

- Non Hazmat

 

F. Special precautions for user related to transport or transportation measures

- Local transport follows in accordance with Dangerous goods Safety Management Law.

- Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

- EMS FIRE SCHEDULE : Non Hazmat

- EMS SPILLAGE SCHEDULE : Non Hazmat

 

 

15. REGULATORY INFORMATION

National legislation

Water contaminating class : 1 slightly water endangering

Classified according to annex 4 of the German VwVwS for preparations.

 

Notification status : EINECS yes

: TSCA no

: DSL no

: AICS yes

: INV (CN) yes

: PICCS (PH) no

: KECI (KR) yes

 

16. OTHER INFORMATION

A. Reference

- The information contained herein is believed to be accurate. It is provided independently of any sale of the product for purpose of hazard communication. It is not intended to constitute performance information concerning the product. No express warranty, or implied warranty of merchantability or fitness for a particular purpose is made with respect to the product or the information contained herein.

 

B. Last date revised

- 2019.12.31

 

C. Other

- This SDS is prepared according to the Globally Harmonized System

 

COMPANY HISTORY:

 

Hot Products

Room Temperature Curing Epoxy Resin For 33KV Electric Insulation, Flame Retardant Flame Retardant ...
Room Temperature Cured EPOXY RESIN With High Dielectric Strength And Volume Resistivity IRON CORE ...
Room Temperature Cure Epoxy Resin For High Heat Resistance 24 Hours Cure Room Temperature Color ...
Clear Room Temperature Epoxy Resin Liquid Epoxy And Hardner For low voltage Electrical Insulation ...
Vacuum Casting Room Temperature Epoxy Epoxy Resin Raw Material CURING EPOXY RESIN FOR COIL FRAME ...
Room Temperature EPOXY RSIN CURING, Pre Filled With Silica Powder Pre Filled withSilica Powder for ...