Fire gas extinguisher cabinet FM200 extinguishing systems 120kg

Cabinet FM200 fire extinguishing installation is included cylinder, jet pipeline, nozzle, valve actuator, such as collection in one. Could connect with auto fire alarm gas control panel, and automatic detect and fire extinguishing. 
 

Specification:

Item

Max 

filing 
(Kg)

20℃storage 
pressure(MPa)
Jet time(S)

Work.Temp  ()

Magnetic valve 
work voltage

Max protection 
volume

Dimension (mm)

GQQ70/

2.5C

702.5≤100~5024VDC106502X453X1530

GQQ90/

2.5C

90136552X453X1690

GQQ120/

2.5C

120182602X503X1580

GQQ150/

2.5C

150227702X573X1635


Application:
1 combustible gas fire;
2 combustible liquid fire;
3 combustible solid surface fire;
4 electrical equipment fire;
 
Also widely used in electronic computer room, disk, paper tape libraries, electronic control equipment room, communications center, television microwave room, library, rare and precious cultural relics museum, archives, fuel oil boiler room, power transformer room, high voltage capacitor room, oil switch room and other expensive equipment such as buildings.Relative to that of other fire extinguishing system for the main scope of application is:
1 valuables priceless treasures or company data files and software;
2 no sprinkler system or the use of water can cause water damage of equipment;
3 personnel resident area;
4 storage space between the cylinder of fire extinguishing agent is limited, should be a small amount of fire extinguishing agent, which can achieve the fire extinguishing efficiency.
 
Working principle and control and operation:

1, Put the selection button of control panel to "automatic", the fire extinguishing system in a state of automatic control. When the fire detector give alarm signal, fire alarm control panel will send out sound and light alarm, and send a joint order, close linkage device, after 0 to 30 s, fire extinguishing order send out, the electromagnetic valve action, and the FM200 cylinder valves open,FM200 through the connecting hose, nozzle discharge and fire extinguishing protection zone.


2, Electrical manual startup control:Put the selection button of control panel to "manual", fire extinguishing system in a state of manual control.When the fire happen, can press the start button on manual control panel or control panel according to the prescribed procedures to start the fire extinguishing system release FM200 and fire extinguishing.In the automatic control state, still can realize electric manual control.


3, Mechanical emergency start control:When the fire happen, the control panel cannot give fire  extinguishing order,should notify the relevant personnel to evacuate the scene, close linkage device, and then pull out the insurance on the electromagnetic valve pin, panting manual button to open the bottle of head valve, release FM200 and fire extinguishing.


4, When the fire alarm found to have abnormal situation in the delay time, do not need to start the fire extinguishing system, according to the manual control box or emergency stop button on the control panel, can stop control panel send fire extinguishing order.

Hot Products

Addressable fire alarm systems 2 wire smoke and heat combine detector SPECIFICATIONS: Operating ...
Addressable fire alarm systems 2 wire heat detector sensor SPECIFICATIONS Height: 2.2˝ (55 mm) ...
Addressable fire alarm systems 2 wire smoke detector sensor SPECIFICATIONS: Operating Voltage Range: ...
Addressable intelligent fire alarm 2 wire systems control panel 792 addresses 4LOOPS and 792 ...
Addressable intelligent fire alarm 2 wire systems control panel 396 addresses 2LOOPS and 396 ...
Addressable fire alarm systems 2 wire bus output module SPECIFICATIONS: Nominal Operating Voltage: ...