Ac Dc Pulsed Current Electronic Measurement Current Transducer

 

Notes:The AC DC leakage current sensor is installed on the positive and negative output lines of the AC or DC circuit. When the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and opposite in direction, and its output signal is zero. When the branch is grounded, The AC DC leakage current sensor has a differential flow, and the output of the sensor is not zero. Therefore, by detecting the output signals of each branch sensor, it can be judged whether they are any leakage current existing.The principle of grounding branch has a high line selection accuracy and is not affected by the distributed capacitance of the line.

 

1. Overview:

● mA Level Measurement

● AC DC Leakage Data Readable

● Alarm Value Programmable, 3 alarm Outputs

● One-body Design, Pin Type Installation

● Widely used for smart meter,smart grid,EV charger,monitoring device,circuit protection,machine equipment

 

 

2. Specification:

Voltage12V±20%
CurrentDC current 2~15mA, AC current 3~100mA
AccuracyDC±0.2mA, AC±0.3mA @ 25℃
3 Ways OutputDC alarm, AC alarm, AC/DC alarm
Operation Temperature Range-25~+80℃
InstallationPin Type
Plastic CasingSIP encapsulation

 

 

3. Application Notes:

3.1. Cautions of smart sensor

(1) Current value- Please specify your measurement range as per your application, for example if you are going to use it for detecting and sensing mA level or high current range such as 500A/600A shall be first factor.

(2) AC,DC,or both AC&DC shall be the second factor. Now current sensor on the market usually are AC or DC type.But if you need both AC& DC you may need to use IVY brand- AC DC leakage sensor.

(3) Parameters-Please confirm what kind of parameters shall be measured or detected. For example our smart sensor with shunt can readout current, voltage,kWh, kVar, Cosφ, Hz, THF, current cycle, starting waveform.

(4) Communication-RS485,M-bus, UART serial port are optional, if you have more requirements we can also develop for you.

(5) Installation Method, after making above decision you may also need to confirm the output terminal type, for example we have shunt / terminal / pillar / pins/ cable etc.

(6) As there are many models of smart electrical sensor, plz refer to the detailed specification and use it as per the instruction.

 

 

4. Why Choose Us

Single Dual Coil IEC Standard UC2 Approved Magnetic Latching Relay 0

 

 

5.FAQ

Q1: What kind of product and service do you have?

We provide all kinds of electronics including power relay, latching relay, change-over switch, current transformer, shunt, smart sensor, communication & power supply module, transformer etc.

The manufacturer of meter instrument, electrical device, EV charger, medical equipment can find one step solution here. Individual buyer,distributor or (sole/ designated) agents are also welcomed by us.

 

 

Q2: Are you are factory or trading company?

We are the manufacturer,designer and sales company. Our own factory was located in Tongxiang city of Zhejiang province.

For our history plz click About us or watch IVY factory video on Youtube.

 

 

Q3: Whether the price will change greatly?

To business customers, we mark price can be negotiated here as huge demand.

Usually we will not change the prices unless some force majeure such as trade war, exchange rate change greatly etc.

 

 

Q4: Can you offer customized solution, how should I get a quotation?

Yes!We can offer customized products especially when we supply EV accessories and meter accessories. To get a quoation plz kindly offer your basic company info for registration and offer your drawing.

It usually takes 12 hours to 48 hours to filnish the design and drawing (If complicated then plz refer to pracatical situation).

 

 

Q5: How do you handle the quality problems?

We are proud of our quality! If any accidents on quality, we have before-sales, in-sales and after-sales service. And every customer will have your own sales expert and technical support.

 

Hot Products

Insulation Failure Over Voltage Protection Circuit Overload Protection Relay 1. Introduction IM902 ...
Ovp Protection Electrical Power Supply Over-Voltage Protection Relay 1. Introduction IM902 is a 90A ...
Anti-Surge 3Ka Protective Relay Over-Voltage-Protection (Ovp) Load Switch 1. Introduction IM902 is a ...
Undervoltage Overvoltage Protector Surge Protective Device Spd Relay 1. Introduction IM902 is a 90A ...
Electrical Safty Over-Current And Short-Circuit Protection Relay 1. Introduction IM902 is a 90A ...
Supply Shut Down Magnetic Latching Relay Overload Relay 1. Introduction IM902 is an equipment ...