Digital Micro Vickers Hardness Tester Micro Hardness Testing Machine with Built-in Software

 

Model: IQUALITROL PCHVT-1000Z

 

Technical Data Download: iqualitrol Micro Vickers Hardness Tester PCHVT-1000Z

 

Brief Introduction:

IQUALITROL PCHVT-1000Z is a new generation of iqualitrol Micro Vickers hardness tester adopts the integrated design of hardness tester and panel computer, all the testing parameters can be selected on the panel computer.

 

Touch screen controller makes the operation quickly and conveniently. CCD image acquisition system can show dynamic indentation image, lock the image and automatically get the Vickers hardness value with high precision and stability, and avoid the human errors.

 

PCHVT-1000Z adopts the integrated design of hardness tester and panel computer, with Windows 7 operating system, it has all functions of computer and can be connected to the output devices such as external screen and printer;

 

PCHVT-1000Z equips with motorized turret between the objective and the indenter;

 

The lifting screw of PCHVT-1000Z adopts worm and gear structure with smooth transmission;

 

PCHVT-1000Z comes with the function of hardness scale conversion;

 

Automatically save the measuring data, generate the hardness-depth curve and save as WORD or EXCEL report;

 

Digital micrometer X-Y test table makes measurement more precise and realizes the fully automation of Micro Vickers hardness testing with optional motorized X-Y test table.

 

Application range:

Suitable for ferrous metal, non-ferrous metals, IC thin sections, coatings, ply-metals; glass, ceramics, agate, precious stones, thin plastic sections etc.; hardness testing such as that on the depth and the trapezium of the carbonized layers and quench hardened layers.

 

Technical Specification:

ModelPCHVT-1000Z
Test Forcegf10gf, 25gf, 50gf, 100gf, 200gf, 300gf, 500gf, 1000gf
N0.098N, 0.246N, 0.49N, 0.98N, 1.96N, 2.94N, 4.90N, 9.80N
Test Range1HV~2967HV
Test ModeHV/HK
Loading MethodAutomatic (Loading/Dwell/Unloading)
TurretAutomatic Turret
ComputerCPU: Intel I3, Memory: 2G, SSD: 32G
CCD Pixel1.30 Million
Conversion ScaleHV, HK, HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HS, HBW
Hardness ReadingIndentation Displaying and Automatic Measuring on Touch Screen
Data OutputWORD or EXCEL Report with Curve Chart
Objective10x (Observe), 40x (Measure)
Total Magnification100x, 400x
Resolution0.0625μm
Dwell Time0~60s
Light SourceHalogen Lamp
Motorized X-Y Test TableSize: 100×100mm; Travel: 25×25mm; Resolution: 0.01mm
Max. Height of Specimen150mm
Throat120mm
Power SupplyAC220V/50Hz/1Ph, AC110V/60Hz/1Ph
Execute StandardISO 6507, ASTM E384, JIS Z2244, GB/T 4340.2
Dimension560×335×675mm, Packing Dimension: 650×380×960mm
WeightNet Weight: 48kg, Gross Weight: 62kg

 

Packing List:

NameQtyNameQty
Instrument Main Body1 setDiamond Micro Vickers Indenter1 pc
10x, 40x Objectiveeach 1 pcWeights6 pcs
Weight Axis1 pcCross Test Table1 pc
Flat Clamping Test Table1 pcThin Specimen Test Table1 pc
Filament Clamping Test Table1 pcHorizontal Regulating Screw4 pcs
Level1 pcPower Cable1 pc
Fuse 1A2 pcsHalogen Lamp 12V/15~20W1 pc
Screw Driver2 pcHardness Block 400~500 HV0.21 pc
Hardness Block 700~800 HV11 pcAnti-dust Cover1 pc
Usage Instruction Manual1 copy  

 

 

Vickers hardness test method:

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.

 

The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 

 

Hot Products

Digital Smart Controller Large Industrial Trolly Drying Oven for Electroplating Industry Main ...
Constant Temperature Medical Thermostatic Incubator with Perfect Air Current Cycling Thermostatic ...
Double Layer Isolation Programmable PID Control Biochemical Incubator for Drug Testing Biochemical ...
Lighting Incubator Thermal Plant Growth Chamber Simulate Day and Night Illumination Light chamber: ...
Microcomputer controller Energy Saving Biological safety cabinet for Biological Experiments ...
Horizontal and Vertical Laminar Flow Lab Clean Bench for Biotechnology Application Laminar Flow ...