HV and HK Scales Motorized Turret Micro Vickers Hardness Tester for Brittle and Hard Materials

 

Technical Data Download: iqualitrol Micro Hardness Tester iVick-D1000ZK

 

Brief Introduction:
● iVick-D1000Z integrated the technology of optics, mechanics and computer, and it is focus on the vickers testing under the small force, and mainly used to measure the hardness of ferrous metals and non ferrous metals;
 
● Equips with LCD screen, displays the measuring methods, testing force, indentation length, hardness value, dwell time of the testing force as well as the number of measurement, the operation is more directly and clearly;
 
● iVick-D1000Z can be set working date, record the measuring results, compute the data, output the information with the printer;
 
● Support hardness conversion among 4 hardness scales, and linking to PC in RS 232 interface and cable;
 
● iVick-D1000ZK adopts the design of double indenters, equips with HV and HK indenter simultaneously, It is more suitable to measure the hardness of IC thin sections, coatings , ply metals; Glass, ceramics, agate , precious stones and other brittle and hard material.
 
Specifications:

Product NameSingle-HV Indenter Digital Micro Vickers Hardness TesterDouble-HV and HK Indenter Digital Micro Vickers Hardness Tester
ModeliVick-D1000ZiVick-D1000ZK
Loading ForceN0.098, 0.246, 0.49, 0.98, 1.96, 2.94, 4.90, 9.80
gf10, 25, 50, 100, 200, 300, 500, 1000
IndenterHV IndenterHV and HK Indenter
TurretAuto-Turret
Indentation MeasurementDigital Sensor Measurement
Loading ControlAutomatic (Loading, Dwell, Unloading)
Magnification of MicroscopeObservation:10x; Measurement:40x
Digital EyepieceMagnification: 10x
Auto Hardness ConversionHV, HRC, HBW
Hardness IndicationLCD display
Dwell TimeAdjustable 1~99s
Testing Range1HV~2967HV
X-Y AnvilSize:100x100mm; Travel:25 x25mm; Resolution:2um
IlluminationAdjustable LED 6V, Cold light-source
DisplayD1, D2, HV/HRC/HB/HK, Time
Vertical Space70mm
Instrument Throat95mm
Power SupplyAC220V/50Hz;110V/60Hz
Dimension(LxWxH)490 x250 x395mm
Packing Dimension530 x450 x750mm
Gross/Net Weight50Kg/40Kg
Execution StandardISO 6507, ASTM E92, JIS Z2244, GB/T4340

 
Standard Delivery:

Vickers IndenterObjectives 10xAccessories Box
Knoop Indenter (iVick-D1000ZK)Objectives 40xAnti-dust Cover
Vickers Hardness Block HV 0.510x Digital EyepieceLevel Screw
Vickers Hardness Block HV 1Power CableInstrument Manual

 
Optional Accessories:

Vickers Measuring SoftwareUnequal Spencimen ClampKnoop indenter
25mm Digital Micrometer HeadFilament ClampUSB Camera
Thin-piece ClampFlat Precision Clamp15x Digital Eyepiece

 

Vickers hardness test method:

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.

 

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.

 

The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 

 

The Knoop hardness test method is mostly used for small parts, thin sections, or case depth work. Knoop indentation is very small, the main application like below:

 

testing very thin materials like foils or measuring the surface of a part,
small parts or small areas,
measuring individual microstructures,
measuring the depth of case hardening by sectioning a part and making a series of indentations to describe a profile of the change in hardness.

 

The Knoop indenter is a pyramid shaped diamond is more elongated or rectangular in shape. The Knoop method is commonly used when indentations are closely spaced or very near the edge of the sample.

 

The width of the Knoop indentation can provide more resolution for measurement and the indentation is also less deep. Consequently, it can be used on very thin materials.

 

Hot Products

Forced Air Precision Drying Oven with Volume 216L Forced air oven is designed to meet both ...
Environment Test Chamber for Sand Dust Resistance Conform IEC60529 IP5X IP6X Brief Introduction: ...
Programmable Temperature Humidity Alternative Climatic Test Chamber Cold Balanced Control Brief ...
Alternative Temperature Humidity Environmental Climatic Test Chamber by Cold Balanced Control ...
Cold Balanced Control Temperature Humidity Alternative Environmental Test Chamber Brief Introduction...
Programmable Humidity Temperature Alternative Test Chamber Controlled by Microprocessor Brief ...