Home Companies Dongguan Quality Control Technology Co., Ltd.

Programmable Thermal Humidity Alternating Climatic Test Chamber by Cold Balanced Control

Dongguan Quality Control Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 301, Building No.1, No. 2 Jiaolian Yiheng Rd, Wanjiang District, Dongguan, China, 523046

Contact name:Raymond Chung

Inquir Now

Dongguan Quality Control Technology Co., Ltd.

Programmable Thermal Humidity Alternating Climatic Test Chamber by Cold Balanced Control

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

 

Programmable Thermal Humidity Alternating Climatic Test Chamber by Cold Balanced Control

 

Data Sheet: iqualitrol Vertical Programmable Temperature Test Chamber

 

Brief Introduction:

iqualitrol programmable temperature test chamber with wide range of temperature controls, mainly used to test performances of materials after in high temperature, low temperature, constant temperature or temperature alternating.

 

Temperature chamber is one of the essential test equipment for aerospace, automotive, home appliances, scientific research department, etc.

 

Temperature humidity test chamber is use to test material heat, cold, dry resistance, humidity resistance. Suitable for electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metal, food, chemical, building materials, medical, aerospace and other products.

 

Products Conform Following Standards:

※ IEC60068-3-5-2002 Environmental testing-Part 3-5 Support documentation and guidance-Confirmation of the performance of temperature chambers

※ IEC68-2-1 (GB-2423.1-2008) Testing A: Low temperature testing method

※ IEC68-2-2 (GB-2423.2-2008) Testing B: High temperature testing method

※ MIL-STD-202F (GJB360.8-87) High temperature life testing

※ MIL-STD-810D (GBJ150.3) High temperature method

※ MIL-STD810D (GBJ150.4) Low temperature method

※ IEC68-2-3 (GB2423.3-93) Testing Ca: Constant moist heat testing method

※ IEC68-2-30 (GB2423.4-93) Testing Db: Alternate moist heat testing method

※ MIL-STD-810D (GJB150.9-93) Moist heat testing method

 

Dimensions by Models:

ModelTemp RangeInternal Dimension
(W x H x D) cm
Exterior Dimension
(W x H x D) cm
QTL-V80B-20℃~﹢150℃40x50x4060x110x95
QTL-V150B50x60x5070x120x105
QTL-V225B50x75x6070x135x115
QTL-V416B70x85x7090x145x125
QTL-V800B100x100x80120x160x135
QTL-V1000B100x100x100120x160x155
QTL-V80C-40℃~﹢150℃40x50x4060x110x95
QTL-V150C50x60x5070x120x105
QTL-V225C50x75x6070x135x115
QTL-V416C70x85x7090x145x125
QTL-V800C100x100x80120x160x135
QTL-V1000C100x100x100120x160x155
QTL-V80D-70℃~﹢150℃40x50x4060x110x95
QTL-V150D50x60x5070x120x105
QTL-V225D50x75x6070x135x115
QTL-V416D70x85x7090x145x125
QTL-V800D100x100x80120x160x135
QTL-V1000D100x100x100120x160x155
Remark: 20%~98%RH is standard humidity range, support custom made 10%~98%RH Or 5%~98%RH
Support custom made dimension

 

Specifications:

Control ModeCold Balanced Control System
Operating Temp. & Humid. Range+5℃ ~ +35℃; <85%R.H.
Temp. RangeA=0℃, B=-20℃, C=-40℃, D=-70℃ ~ +100℃(150℃)
Temp. Fluctuation±0.5℃
Temp. Uniformity≤2.0℃
Temp. Resolution0.01℃
Temp. Heating Time-40℃ ~ +150℃within 35 min; -70℃ ~ +150℃within 60 min
Temp. Cooling Time20℃ ~ -40℃within 60 min; 20℃ ~ -70℃within 90 min
Power SupplyAC380V, 50/60HZ, Three-phase (Specified by User)
MaterialExterior MaterialStainless steel with baking paint
Interior MaterialSUS304# Stainless steel
Insulation MaterialRigid polyurethane foam
Refrigeration SystemRefrigerating MethodMechanical cascade refrigeration system
CompressorAir cooling hermetic compressor
RadiatorFin type radiator
RefrigerantRefrigerant R404A
Heating SystemStainless steel radiating heater
ControllerTouch screen controller HL-1000
Safety Devices

Overheat protector Switch

Compressor overload protector switch

Fault alarm system

Accessories

Viewing window, Chamber lamp, Cable port ø50mm,

Product shelf slides 2 pieces, universal casters

Touch screen controller HL-1000

Note:

1. The performance values are no specimen inside the test area

2. At 20℃ ambient temperature, rated voltage

3. According to IEC68-2-1 and IEC68-2-2

4. The above specifications are for reference only.

 

Features:

※ Heating/Cooling System: Completely independent heating/cooling system can improve testing efficiency and using life.

 

※ Cycle System: Powerful blowing cycle system to avoid blind angle, makes temperature and humidity evenly distributed in the test area.

 

※ Viewing window and interior light makes viewing workspace freely and observe the test under best conditions.

 

※ Touch screen controller HL-1000 is designed to save chamber programming and setup time with temperature limit and alarm to protect your product.

 

※ Safety relay connection is provided to protect your device under test by removing power to it when the chamber is not running.

 

※ RS-232 communications is for computer connection, programming can be set on computer by software, monitor testing process and automatically execute power on/off functions.

 

※ Chamber exterior material is stainless steel with environmentally baking paint resists corrosion and provides impact resistance. Interior material is SUS304# stainless steel with excellent heat resistance and easy to clean.

 

※ Adjustable product shelf slides out for easier product access. Shelf design is non-tipping and supports large product loads.

 

※ Left side of chamber with diameter 50mm cable port for power-on test.

 

 

 

 

Hot Products

Programmable Vertical Temperature and Humidity Test Chamber with Touch Screen Controller Technical ...
Industrial Hot Wind Drying Oven with SUS304 Mirror Stainless Support Customized Dimension Data Sheet...
Programmable Thermal Humidity Alternating Climatic Test Chamber by Cold Balanced Control Data Sheet: ...
Desk Type Programmable Temperature Humidity Test Chamber 32L Test Space Technical Data Download: ...
Programmable Temperature and Humidity Test Chamber with Overheating Protector Programmable ...
IEC60529 Dust Resistance Test Chamber with Temperature and Humidity Control System Brief Introductio...