Large LCD Automatic Turret Micro Knoop Vickers Hardness Tester with Thermal Printer

 

Model: iVick-456MP

 

Technical Data Download: iqualitrol Micro Vickers Hardness Tester iVick-456MP

 

Brief Introduction:

iqualitrol iVick-456MP Digital Micro Vickers hardness tester is a high-tech and new product combining the optics, mechanic and electrics features.

 

With a novel and pleasing appearance, the internal structure is mainly made by stainless steel parts, has better performance.

 

It can directly show the test mode, test force, indentation length, dwell time, test numbers, conversion scale, date and time on the large screen.

 

As long as press the eyepiece button after measuring the indentation length, it can automatically get the hardness value and shows on the screen.

 

With the up and down limit alarm function, test results can be saved for reviewing or be printed out by the built-in printer, and with RS232 interface for connecting to the computer.

 

Available to use optional Knoop indenter to measure Knoop hardness.

Support to equip with LCD video measuring device and CCD image automatic measuring system.

 

Application range:

Suitable for ferrous metal, non-ferrous metals, IC thin sections, coatings, ply-metals; glass, ceramics, agate, precious stones, thin plastic sections etc.; hardness testing such as that on the depth and the trapezium of the carbonized layers and quench hardened layers.

 

Technical Specification:

ModeliVick-456MP
Test Forcegf10gf, 25gf, 50gf, 100gf, 200gf, 300gf, 500gf, 1000gf
N0.098N, 0.246N, 0.49N, 0.98N, 1.96N, 2.94N, 4.90N, 9.80N
Test Range1HV~2967HV
Test ModeHV/HK
Loading MethodAutomatic (Loading/Dwell/Unloading)
TurretAutomatic Turret
Conversion ScaleHV, HK, HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HS, HBW
Data OutputBuilt-in Printer, RS232 Interface
Hardness ReadingLCD Display, Data can be saved
Objective10x (Observe), 40x (Measure)
Eyepiece10x
Total Magnification100x, 400x
Resolution0.015μm
Dwell Time0~95s
Light SourceHalogen Lamp
X-Y Test TableSize: 100×100mm; Travel: 25×25mm; Resolution: 0.01mm
Max. Height of Specimen90mm
Throat120mm
Power SupplyAC220V/50Hz/1Ph, AC110V/60Hz/1Ph
Execute StandardISO 6507, ASTM E384, JIS Z2244, GB/T 4340.2
Dimension495×305×550mm, Packing Dimension: 600×360×800mm
WeightNet Weight: 35kg, Gross Weight: 44kg

 

 

Packing List:

NameQtyNameQty
Instrument Main Body1 set10x Digital Eyepiece1 pc
Diamond Vickers Indenter1 pc10x, 40x Objectiveeach 1 pc
Weights7 pcsPower Cable1 pc
Cross Test Table1 pcFlat Clamping Test Table1 pc
Thin Specimen Test Table1 pcFilament Clamping Test Table1 pc
Horizontal Regulating Screw4 pcsLevel1 pc
Fuse 1A2 pcsHalogen Lamp 12V/15~20W1 pc
Inner Hexagon Spanner1 pcScrew Driver1 pc
Plastic Absorbing Plate1 pcColor Filter1 pc
Hardness Block 400~500 HV0.21 pcHardness Block 700~800 HV11 pc
Anti-dust Cover1 pcUsage Instruction Manual1copy

 

 

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.

 

 

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.

 

The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 

 

 

Hot Products

Forced Air Precision Drying Oven with Volume 216L Forced air oven is designed to meet both ...
Xenon Lamp Temperature Test Chamber Weathering Test Equipment With Touch Screen Product Summary: ...
Three Layers Programmable Temperature Humidity Alternative Test Chamber Model: iTemp-K380A Brief ...
Touch Screen Controller UV Weather Resistance Test Chamber Conform ASTM Standard Technical Data ...
Touch Controller Large Size Walk in Programmable Temperature and Humidity Test Chamber Brief ...
Programmable Vertical Temperature and Humidity Test Chamber with Touch Screen Controller Technical ...