Home Companies Dongguan Quality Control Technology Co., Ltd.

Max Height 170mm Digital Vickers Hardness Testing Machine with Max 400x Magnification

Dongguan Quality Control Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 301, Building No.1, No. 2 Jiaolian Yiheng Rd, Wanjiang District, Dongguan, China, 523046

Contact name:Raymond Chung

Inquir Now

Dongguan Quality Control Technology Co., Ltd.

Max Height 170mm Digital Vickers Hardness Testing Machine with Max 400x Magnification

Country/Region china
City & Province dongguan guangdong
Categories Other Shoes
InquireNow

Product Details

 

Max Height 170mm Digital Vickers Hardness Testing Machine with Max 400x Magnification

 

Technical Data Download: iqualitrol Vickers Hardness Tester iVick-476H

 

Brief Introduction:

iqualitrol iVick-476H Digital Vickers hardness tester adopts load cell control system, improves the precision of the test force and the repeatability and stability of the indicating value.
 
With digital measuring eyepiece, no need for checking the table or inputting the diagonal of the indentation, it can directly show the test force, indentation length, dwell time, test numbers, conversion scale, date and time.
 
As long as press the eyepiece button after measuring the indentation length, it can automatically get the hardness value and shows on the screen.
 
Available to install optional LCD video measuring device and CCD image automatic measuring system.
 
Application range:
Suitable for ferrous metal, non-ferrous metals, IC thin sections, coatings, ply-metals; glass, ceramics, agate, precious stones, thin plastic sections etc.; hardness testing such as that on the depth and the trapezium of the carbonized layers and quench hardened layers.
 
Technical Specification:

ModeliVick-476H
Test Forcekgf0.3kgf, 0.5kgf, 1kgf, 2kgf, 2.5kgf, 3kgf, 5kgf, 10kgf
N2.94N, 4.90N, 9.80N, 19.6N, 24.5N, 29.4N, 49N, 98N
Test Range1HV~2967HV
Loading MethodAutomatic (Loading/Dwell/Unloading)
TurretManual Turret
Data OutputNone
Objective10x, 40x
Eyepiece10x
Total Magnification100x, 400x
Resolution0.25μm, 0.0625μm
Dwell Time0~60s
Light SourceHalogen Lamp
X-Y Test TableSize: 100×100mm; Travel: 25×25mm; Resolution: 0.01mm
Max. Height of Specimen170mm
Throat130mm
Power SupplyAC220V/50Hz/1Ph, AC110V/60Hz/1Ph
Execute StandardISO 6507, ASTM E92, JIS Z2244, GB/T 4340.2
Dimension530×280×630mm, Packing Dimension:620×450×740mm
WeightNet Weight: 35kg, Gross Weight: 47kg

 
Packing List:

NameQtyNameQty
Instrument Main Body1 set10× Digital Measuring Eyepiece1 pc
Diamond Vickers Indenter1 pc10x, 40x Objectiveeach 1 pc
X-Y Test Anvil1 pcPower Cable1 pc
Horizontal Regulating Screw4 pcsLevel1 pc
Fuse 1A2 pcsHalogen Lamp 12V/15~20W1 pc
Inner Hexagon Spanner 2.5mm1 pcScrew Driver1 pc
Hardness Block 700~800 HV11 pcHardness Block 700~800 HV101 pc
Anti-dust Cover1 pcUsage Instruction Manual1 copy

 

 

Vickers Hardness Tester Lens and Indenter:

 

 

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.

 

 

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.

 

The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 

 

Hot Products

Xenon Lamp Temperature Test Chamber Weathering Test Equipment With Touch Screen Product Summary: ...
Three Layers Programmable Temperature Humidity Alternative Test Chamber Model: iTemp-K380A Brief ...
Touch Screen Controller UV Weather Resistance Test Chamber Conform ASTM Standard Technical Data ...
Touch Controller Large Size Walk in Programmable Temperature and Humidity Test Chamber Brief ...
Programmable Vertical Temperature and Humidity Test Chamber with Touch Screen Controller Technical ...
Industrial Hot Wind Drying Oven with SUS304 Mirror Stainless Support Customized Dimension Data Sheet...