Hottest Fractional RF treatment machine for Skin Rejuvenation / Skin Tightening

Functions:

•Wrinkle removal, skin lightening
•Skin lifting and tighten Elasticity enhancement
•skin smooth
•pore shrinking, calming down redness.
•Orange tissue removal
•remove stretch marks
•Improve pores

Technical Data

Input Voltage: AC 220V/150Hz     AC  110V/60Hz

Output Power:55VA

LED: Red 650nm/5mWX1

Benefits:

1.non-surgical,non-invasive prodedure.
2.no general anesthesia required.
3.no down time allows return to usual activities without delay.
4.gradual improvement in appearance rather than sudden change.


Parts Introduction


 

1.Touchscreen

2.Non-adjustable low speed handle

3.Adjustable low speed handle

4.Service brake

5.Power switch

6.Power supply line jack

Accessories


 

Basal Operation


1. First,insert the steadying bar into the frame hole,aim the hole in steadying bar at the hole in frame ,the  fasten  it  with   hex   socket   screws.   Then   put   the accessories frame into the steadying bar.

2.Put the accessories well and connect them to host.

(1)Insert the Non-adjustable low speed handle into jask[2].

(2)Insert the adjustable low speed handle into jask[3]

(3)Put the brake service on the ground,Insert the brake service into jack

[4],turn on the power switch

[5],input default password “000000” to enter interface as shown in (Fig 1)

4.In interface as(Fig1) shows:

1.Click on “basic setting” to select Language,set Date and Time.

2.The “advanced setting” is only for manufacturer,Users do not use.

3.Click on”picture” to enter interface as (Fig 2)

4.Click on”” to return interface as (Fig 1)


Thermage Treatment

Non-adjustable Low speed handle

Suitable for thermage work head.Click on the “II” step on the service brake once,the thermage work head is only output once.

SRF Nursing process

1.Deep clean the treated skin.

2.Applied anesthetic in the nursing area,and to be anesthetic effect.

3.Apply cold gels on the treated skin.

4.In interfase as shown (Fig 2), click on “low speed SRF” to enter interface as (Fig 3) Thermage treatment function.

5.lnsert the Thermage work head into the Non-adjustable low speed handle.

6.Set working time. The system default work time is 30 minute,click on "<<" and ">>" of work time to regulate,the range is 1 to 120 minutes.

7.Select the work mode. The system default automatic mode is P4,click on "<<" and ">>" of automatic mode to regulate,the details is following:

Automatic mode:

M1 3000ms(long)

M22600ms

M32200ms

M41800ms

M51400ms

M61000ms(short)

Manual mode: 1000ms to 3500ms

8.Set RF output intensity. The system default RF intensity is 1,click on "<<" and ">>" of RF intensity to set,the range is 1(weak) to 8(strong)

9.Click on “PDT” select turn on/off light therapeutics.

10.Click”II”,the system begin to work,the beautician hold the non-adjustable low-speed handle cluing to the skin,Step on the service brake with foot once,then release,move the handle in adifferent part to continue operating.Beautician step on service brake each time,mean that the Thermage work head output engage once at same time.

11.When Thermage treatment is completed.we may use lce to cool the skin,it can relieve swelling,relieve pain effect.

12.Click on”” to return interface as(Fig 1).

MRF Treatment


Adjustable Low speed handle:

Suitable for MRF micro-needle work head. Adjustable means that the output length of MRF micro­ needle work head can be adjusted. Click on "11" ,step on service brake once,the micro-needles work head is only output once.

MRF Nursing process

1.Deep clean the treated skin.

2.Applied anesthetic in the nursing area,and to be anesthetic effect.

3.Apply effective products in the treated skin.

4.Click on “Low speed MRF” to enter interface as (Fig 4) MRF treatment function

5.Chooce appropriate micro-needle work head,in sert it into the adjustable Low-speed handle

6.Depending on treatment part,adjusting the length of the micro-needles(twisting yellow ring).

0.25,0.5 is suitable for eyes

1.0,1.5,2.0 is suitable for face

2.0.2.2,3.0 is suitable for bady

7.set working time

8.Select “Time of needles being out”.The system defaule is 300ms, click on "<<" and ">>" to adjust,the range is 250ms to 600ms.

250ms to 300ms is suitable for eyes

300ms to 450ms is suitable for face.

450ms to 600ms is suitable for body.

9. Select “Time difference of MRF and needles being out”,The system default is 2ms,click "<<"and ">>" to adjust, the range is 1ms(fast) to 10ms(slow).O-stands for MRF and needle output at same time.

10.Regulate “RF intensity”.The system default is 1,click on "<<"and ">>" to adjust,the range:1(weak)~10(strong).OFF stands for close MRF function.

11.Click on “PDT”,selest turn on/off light therapeutics

12.Click on “II”,the system begin to work,the beautician hold Adjustable low-speed handle cluing to slin.Step on service brake with foot once,then release,move the handle in a different part to continue operating.Beautician step on service brake each time,means that the MRF micro-needles work head output engage once at same time.

CAUTION:During face and body treated,when the length of MRF micro-needles work head arrive 2.0mm or above; MRF intensity arrive 8 or above; we recommended only operate one time in the same location.Do not repeat operating twice.

13,when MRF treatment is completed.we may use lce to cool the skin,it can relieve swelling,relieve pain effect.

SRF&MRF Cautions

1.When insert MRF micro-needles work head and Thermage work head to the handle,you must check and confirm whether fully inserted.

2.During the treating,  the customer do not wear any metal ornaments

3.Must apply cold gel when use dot matrix SRF electrode head.

4.We recommended  to tum off red led therapeutics when do eyes treated.

5.When gels or other cream products get into Thermage work head,high temperature is easy caused smoking ,please cleansing it immediately

Forbidden Group

1.People with heart disease or high blood pressure,,or configured cardiac pacemaker

2.Patients with acute inflammation,asthma,deep vein thrombosis,thyroncus,caner

3.People with hemorrhagic disease,trauma or who is bleeding.

4.Pregnant women

5.Medical Plastic parts,or parts with artificial in filling inside

6.People with metal inside the body(include metallic tooth)

7.Patient with skin inflammation or with edema

8.People with an abnormal immune system

9.Numb or insensitive to heat

Technical note

Hardware structure of the machine parts,injection molded parts,and the majority of electronic components,connectors,meet the requirements of the EU and China RoHS directives,Only a few part as the global technology limitatiobs that may affect product reliability,and not find a substitute for the toxic and hazardous substances,please be assured to use,use under normal conditions will not cause health effets on users.

Our factory


Hot Products

30w/40W Fractional Co2 Laser Surgical Products vaginal applicator co2 Specifications: Laser type USA ...
30w/40W Fractional Co2 Laser Surgical Products vaginal applicator co2 Specifications: Laser type USA ...
manufacture 30w RF CO2 Burn Debridement Treatment Fractional Laser Beauty Machine for sale ...
factory vertical fractional co2 lasers Fractional CO2 Laser Burn Scar Removal 2018 Specifications: ...
high quality 400w ultrapulse co2 laser tube medical laser system portable co2 fractional laser price ...
ce approved CO2 Fractional Laser for wrinkle removal scars removal acne removal Specifications: ...