Home Companies Henan Universe Intraocular Lens Research and Manufacture Co., Ltd.

3.5mmX3.0mm Glaucoma Drainage Device Implant ISO Aqueous Tube Shunt

Henan Universe Intraocular Lens Research and Manufacture Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Torch Building A, No. 8 Guohai Ave., Zhengzhou, Henan 450001, China

Contact name:Liu

Inquir Now

Henan Universe Intraocular Lens Research and Manufacture Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

3.5mmX3.0mm Glaucoma Drainage Device Implant ISO Aqueous Tube Shunt

Country/Region china
City & Province zhengzhou henan
InquireNow

Product Details

Glaucoma Drainage Implant for Penetrating Trabeculectomy

 

Glaucoma Drainage Implant for penetrating trabeculectomy Material

Glaucoma Drainage Implant for penetrating trabeculectomy is produced with biomaterial ethoxyl methacrylate ester/methylmethacrylate copolymer(2-HEMA-co-MMA), which is nontoxic, has no immune ewsponse, has good biological compatibility, and cannot be absorbed by tissue. As materials of intraocular lens, it has been clinically applied in ophthalmology for more than ten years, and is universally accepted as good intraocular implantion material by ophthalmology circle.

 

Glaucoma Drainage Implant for penetrating trabeculectomy has two kinds: type FPT(for penetrating trabeculectomy) and type FNPT(for nonpenetrating trabeculectomy). The overall length of type FNPT is 4.5mm, and the width of slot is 0.7mm. The length of side of type FPT is 3.5mm.There are 4 holes on the Glaucoma Drainage Implant, which used for fixation on sclerotic bed and osmosis of aqueous humor. To implant the Glaucoma Drainage Implant into resected deep sclerotic bed to form a cavity which is called aqueous humor "pond" or "depressurizing room" the upper bottom of linguiform one is exposed to the outside of sclerotic valve, that is made for aqueous humor being drained from the "pond", "cavity" to the underside of conjunctiva, and promoting the formation of new aqueous humor channel, and thus to achieve the goal of reducing intraocular pressure.

 

Characteristics of Glaucoma Drainage Implant for penetrating trabeculectomy

1. Raw material: Hydrophilic acrylate. .

2. Which has good biological compatibility, and cannot be absorbed by tissue. .

3. Prohibit the growth of fibrocyte, and prevent the formation of filter channel cicatricle. .

4. To impel the formation of new aqueous humor drainage channel. .

5. Distributary of aqueous humor is formed after the implantation of drainage device.

6. It is safe for long-term usage, and intraocular pressure can be effectively controlled. .

7. To increase the success rate and reliability of Glaucoma operation.

Hot Products

Rigid polymethyl methacrylate (PMMA) Scleral fixation of intraocular lens (SFIOL) Scleral fixation ...
HA Hydrophilic Acrylic Foldable Intraocular Lens Iol Zero Aberration Hydrophilic IOLs tend to be ...
Modified C Haptic Hydrophilic Intraocular Lens In Cataract Surgeries Hydrophobic acrylic (HA) ...
Spherical 12.5mm Foldable Hydrophilic Iol High Tensile Strength Hydrophilic Iol initial popularity ...
Cataract Surgery Hydrophilic Intraocular Lens With Excellent Biocompatibility Hydrophilic and ...
Product Parameters: Product Name Heparin surface Modified aspheric IOLs Model PCF60/AH Power 4.0D-30...