Guangdong Shengyu Cable Industry Co., Ltd. |
|
Flexible Heat Resistant Electrical Wires & Cable PVC Compound Insulation
Application
Flexible cable for dry areas, used for purposes requiring special
flexibility in conditions free of any mechanical stresses.
Permitted frequent bending and twisting. Specially suitable for
application in small devices with low mechanical loads and for
connection of light household devices such as kitchen appliances,
desk lamps, ceiling lamps, vacuum cleaners, office machines, radios
etc., as long as the cable is adapted to essential specifications
of the device.
Standards
HRN HD 21.5 S3
IEC 60227-5
DIN VDE 0281 part 5
Construction
Conductor: | bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 (nominal diameter 0,20 mm) | |
Insulation: | PVC compound TI2 acc. to DIN VDE 0207 4. part / HD 21.1 S4, concentrically stranded cores color marked acc. to HRN HD 308 S2 / DIN VDE 0293-308, with or without yellow-green protective conductor | |
Sheath: | PVC compound TM2 for flexible insulated conductors acc. to DIN VDE 0207 part 5 / HD 21.1 S4 | |
sheath colour: | white or black | |
Core colour marking: | HRN HD 308 S2 / VDE 0293-308 | |
Technical data
Temperature range: | |
during installationi: | +5 °C up to +70 °C |
fixed installed: | -30 °C up to +70 °C |
at short circuit of max. 5 s: | up to 150 °C |
ambient temperature at storage: | up to 40 °C |
Nominal voltage: | Uο/U = 300/500 V |
Test voltage: | 2000 V |
Minimal inner bending radius: | 4D for D < 8 mm 5D for 8 - 12 mm 6D for D > 12 mm |
Behaviour in fire: | IEC 60332-1 |
Dimensions – number of cores x conductor cross-section | Construction of individual conductor | External diameter | Insulation thickness | Sheath thickness | Conductor resistance at 20 °C | Specific el. resistance of insulation at 70 °C | Cu weight | Cable weight | Packing** |
nominal | min-max. | nominal | nominal | max. | min. | approx. | |||
mm² | n x mm | mm | mm | mm | Ω/km | MΩkm | kg/km | kg/km | |
2 x 0,5 | 16 x 0,20 | 4,6 - 5,9 | 0,5 | 0,6 | 39,0 | 0,012 | 9,6 | 41 | c.100 |
2 x 0,75 | 24 x 0,20 | 4,9 - 6,3 | 0,5 | 0,6 | 26,0 | 0,010 | 14,4 | 48 | c.100 |
3 G 0,5 | 16 x 0,20 | 4,9 - 6,3 | 0,5 | 0,6 | 39,0 | 0,012 | 14,4 | 48 | c.100 |
3 G 0,75 | 24 x 0,20 | 5,2 - 6,7 | 0,5 | 0,6 | 26,0 | 0,010 | 21,6 | 57 | c.100 |
4 G 0,5 | 16 x 0,20 | 5,4 - 6,9 | 0,5 | 0,6 | 39,0 | 0,012 | 19,2 | 58 | c.100 |
4 G 0,75 | 24 x 0,20 | 5,7 - 7,3 | 0,5 | 0,6 | 26,0 | 0,010 | 28,8 | 70 | c.100 |
5 G 0,75 | 24 x 0,20 | 7,1 | 0,5 | 0,6 | 26,0 | 0,010 | 36,0 | 87 | c.100 |
*) G =with yellow-green protective conductor x= without yellow-green protective conductor
**) Packing: c.100 = coil 100 m