MTL5514 Switch / Proximity Detector Interface Normal Phase

Country/Region china
City & Province shenzhen
Categories Other Switches
InquireNow

Product Details

 

Quick Detail of DETECTOR INTERFACE

 
Number of channels:One
Location of switch:
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs:
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)

Description of DETECTOR INTERFACE

 
The MTL5514-T enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.
 

Specification of DETECTOR INTERFACE

 

Number of channelsOne
Location of switchZone 0, IIC, T6 hazardous area
 Div.1, Group A, hazardous location
 Location of proximity detector
 Zone 0, IIC, T4–6 hazardous area, if suitably certified
 Div.1, Group A, hazardous location
Hazardous–area inputsInputs conforming to BS EN60947–5–6:2001 standards for
 proximity detectors (NAMUR)
Voltage applied to sensor7 to 9V dc from 1kΩ ±10%
Input/output characteristicsNormal phase
 Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
 Outputs open if input < 1.2mA (> 10kΩ in input circuit)
 Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected) 
 User-selectable via switches on the side of the unit. Line faults
 are indicated by an LED. Line fault relay is energised and channel
 output relay de-energised if input line-fault detected
 Open-circuit alarm on if Iin < 50µA
 Open-circuit alarm off if Iin > 250µA
 Short-circuit alarm on if Rin < 100Ω
 Short-circuit alarm off if Rin > 360Ω
 Note: Resistors must be fitted when using the LFD facility with a contact input
 500Ω to 1kΩ in series with switch
 20kΩ to 25kΩ in parallel with switch
Safe-area output 
 Channel: Single pole relay with changeover contacts
 LFD: Single pole relay with changeover contacts
 Note: reactive loads must be adequately suppressed

 

Feature of DETECTOR INTERFACE

 
·1-channel,
·line fault detection,
·phase reversal
 


 

Advantage of Our Team

 
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
 

Frequently Asked Questions:

 
Q: Does your goods are new and original?
A: Yes, they are new and original.
 
Q: How long warranty?
A: One-year warranty.
 
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with us.
 



































Hot Products

Proline Promag PTFE Liner Electromagnetic Flowmeter 5P2B1F-AAACCAEA1K0A​ 5P2B1F-AAACCAEA1K0A Proline ...
Proline Promass Coriolis Flowmeter 8F2B80-BBEEBASAABSA+AADCJBJC 8F2B80-BBEEBASAABSA+AADCJBJC Proline ...
230VAC E&H Instrument CM442 CM442-AAM1A2F010A+AA Transmitter CM442-AAM1A2F010A+AA 1-/2-Channel ...
CLS21D E&H Instrument Digital Conductivity Meter Condumax CLS21D-C1E1 Digital Conductivity Sensor ...
25bar 2.5MPa E&H Instrument Absolute And Gauge Pressure Cerabar PMP23 PMP23-AA1U1RBWSJ+QJ Absolute ...
HART 4 Channel Transmitter Liquiline CM444 Enclosed Cable Entry CAM21A3FG11BAA 4-Channel Transmitter ...