Quick Detail of SMART Transmitter Power Supply

 

Manufacturer : Bently Nevada
Product No. : KFD2-STC4-EX2-Y1
Product type : SMART Transmitter Power Supply, Output Current Sink
Signal type : Analog input
Supply Connection : Power Rail or terminals 14+, 15-
Rated voltage Ur : 20 ... 35 V DC
Power dissipation : 1.9 W
Power consumption = : 2.8 W
Dimensions : 2 x 12.4 x 11.5 cm (0.8 x 4.9 x 4.5 inch) , housing type B2
Weight : 0.2 Kg
Shipping weight : 1.5 Kg

 

Description of SMART Transmitter Power Supply

 

This isolated barrier is used for intrinsic safety applications.
The device supplies 2-wire SMART transmitters in a hazardous area.
It transfers the analog input signal to the safe area as an isolated current value.
Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.

 

Specification of SMART Transmitter Power Supply

 

General specifications
Signal typeAnalog input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionPower Rail or terminals 14+, 15-
Rated voltage20 ... 35 V DC
Ripplewithin the supply tolerance
Power dissipation1.9 W
Power consumptionmax. 2.8 W
Input
Connection sidefield side
Connectionterminals 1+, 3-; 4+, 6-
Input signal0/4 ... 20 mA
Available voltage≥ 16 V at 20 mA, terminals 1+, 3
Output
Connection sidecontrol side
Connectionterminals 7+, 8-; 10+, 11-
Output signal0/4 ... 20 mA (overload > 25 mA)
Ripplemax. 50 µA rms
External supply (loop)11 ... 30 V DC
Transfer characteristics
Deviationat 20 °C (68 °F), 0/4 ... 20 mA
≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
 Influence of ambient temperature0.25 µA/K
Frequency rangefield side into the control side: band width with 1 Vpp signal 0 ... 7.5 kHz (-3 dB)
safe area to hazardous area: band width with 1 VSS signal 0.3 ... 7.5 kHz (-3 dB)
Settling time200 µs
Rise time/fall time20 µs
Galvanic isolation
Output/power supplyfunctional insulation, rated insulation voltage 50 V AC
Output/Outputfunctional insulation, rated insulation voltage 50 V AC
Indicators/settings
Display elementsLED
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility 
 Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2012
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 200 g
Dimensions20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , (W x H x D) housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateBAS 99 ATEX 7025 X
 MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
 Input[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
 Voltage25.2 V
 Current93 mA
 Power0.586 W
Supply 
 Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
CertificateTÜV 99 ATEX 1499 X
 MarkingEx-Hexagon II 3G Ex nA II T4 [device in zone 2]
Galvanic isolation 
 Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
 Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity 
 Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval 
 Control drawing116-0428 (cULus)
IECEx approval 
 IECEx certificateIECEx BAS 04.0015X
IECEx CML 15.0055X
 IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Ex nA IIC T4 Gc

 

Feature of SMART Transmitter Power Supply

 

·2-channel isolated barrier
·24 V DC supply (Power Rail)
·Input 2-wire SMART transmitters
·Output 0/4 mA ... 20 mA current sink
·Terminal blocks with test sockets
·Up to SIL 2 acc. to IEC/EN 61508

 

 

Advantage of Our Team

 

Best possible prices and delivery time

Long time experience in the field

Well trained staff

Own warehouse facilities

Best relationships with branch office of manufacture

Flexible and individual service for you

Cheap and safe forwarder for shipments (air)

 

Frequently Asked Questions:

 

Q: Does your goods are new and original?

A: Yes, they are new and original.

 

Q: How long warranty?

A: One-year warranty.

 

Q: Does any certificates can be provided?

A: Yes, it depends on what product you request, please check details with us.

 

 

Hot Products

Proline Promag PTFE Liner Electromagnetic Flowmeter 5P2B1F-AAACCAEA1K0A​ 5P2B1F-AAACCAEA1K0A Proline ...
Proline Promass Coriolis Flowmeter 8F2B80-BBEEBASAABSA+AADCJBJC 8F2B80-BBEEBASAABSA+AADCJBJC Proline ...
230VAC E&H Instrument CM442 CM442-AAM1A2F010A+AA Transmitter CM442-AAM1A2F010A+AA 1-/2-Channel ...
CLS21D E&H Instrument Digital Conductivity Meter Condumax CLS21D-C1E1 Digital Conductivity Sensor ...
25bar 2.5MPa E&H Instrument Absolute And Gauge Pressure Cerabar PMP23 PMP23-AA1U1RBWSJ+QJ Absolute ...
HART 4 Channel Transmitter Liquiline CM444 Enclosed Cable Entry CAM21A3FG11BAA 4-Channel Transmitter ...