Pepperl+Fuchs KFD2-SR2-Ex2.W Switch Amplifier

Country/Region china
City & Province shenzhen
Categories Other Switches
InquireNow

Product Details

 

Quick Detail of Switch Amplifier

 

Manufacturer : Pepperl+Fuchs
Product No. : KFD2-SR2-EX2.W
Product Type : Switch Amplifier
Signal type : Digital Input
Safety Integrity Level (SIL) : SIL 2
Connection : Power Rail or terminals 14+, 15-
Rated voltage : 20 ... 30 V DC
Power dissipation : 1 W
Power consumption : < 1.3 W
Switching frequency : = 10 Hz
Display elements : LEDs
Ambient temperature : -20 ... 60 °C (-4 ... 140 °F)
Degree of protection : IP20
Connection : screw terminals
Dimensions : 2cm x 11.9cm x 11.5 cm
Weight. : 0.15Kg
Shipping Weight : 1 Kg

 

Description of Switch Amplifier

 

The transformer isolated barrier transfers digital signals from the hazardous area. Sensors per EN 60947-5-6 (NAMUR) and mechanical contacts may be used as alarms. Control circuits are monitored for lead breakage (LB) and short circuit (SC). The external faults are indicated according to NAMUR NE44 by a redflashing LED.
For type KFD2-SR2-Ex2.W, an LB/SC collective error message is in addition transferred through the Power Rail to the power feed module.

 

Specification of Switch Amplifier

 

General specifications
Signal typeDigital Input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3
Supply
ConnectionPower Rail or terminals 14+, 15-
Rated voltage19 ... 30 V DC
Ripple≤ 10 %
Rated current≤ 50 mA
Power dissipation≤ 1 W
Power consumption≤ 1 W
Input
Connection sidefield side
Connectionterminals 1+, 2+, 3-; 4+, 5+, 6-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratiomin. 20 ms / min. 20 ms
Output
Connection sidecontrol side
Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I, IIsignal, relay
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Mechanical life107 switching cycles
Collective error messagePower Rail
Transfer characteristics
Switching frequency≤ 10 Hz
Galvanic isolation
Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility 
 Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage 
 Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019
Conformity
Electromagnetic compatibilityNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
Degree of protectionIEC 60529:1989+A1:1999+A2:2013
Functional safetyIEC/EN 61508:2010
InputEN 60947-5-6:2000
Ambient conditions
Ambient temperature-20 ... 70 °C (-4 ... 158 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificatePTB 00 ATEX 2080
 MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
 InputEx ia
 Voltage10.5 V
 Current13 mA
 Power34 mW (linear characteristic)
Supply 
 Maximum safe voltage253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Output 
 Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Fault indication output 
 Maximum safe voltage40 V DC (Attention! Um is no rated voltage.)
CertificatePF 08 CERT 0803
 MarkingEx-Hexagon II (3)G [Ex ic Gc] IIC
InputEx ic
 Voltage10.5 V
 Current13 mA
 Power34 mW (linear characteristic)
CertificateTÜV 99 ATEX 1493 X
 MarkingEx-Hexagon II 3G Ex ec nC IIC T4 Gc
Galvanic isolation 
 Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
 Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity 
 Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019
International approvals
FM approval 
 FM certificateFM19US0207X
 Control drawing116-0035
UL approvalE106378
 Control drawing116-0473 (cULus)
 Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
IECEx approval 
 IECEx certificateIECEx PTB 11.0034 , IECEx TUN 19.0013X
 IECEx marking[Ex ia Ga] IIC
[Ex ia Da] IIIC
[Ex ia Ma] I
Ex ec nC IIC T4 Gc

 

Feature of Switch Amplifier

 

·2-channel isolated barrier
·24 V DC supply (Power Rail)
·Dry contact or NAMUR inputs
·Relay contact output
·Line fault detection (LFD)
·Reversible mode of operation
·Up to SIL 2 acc. to IEC 61508/IEC 61511

 

 

Advantage of Our Team

 

Best possible prices and delivery time

Long time experience in the field

Well trained staff

Own warehouse facilities

Best relationships with branch office of manufacture

Flexible and individual service for you

Cheap and safe forwarder for shipments (air)

 

Frequently Asked Questions:

 

Q: Does your goods are new and original?

A: Yes, they are new and original.

 

Q: How long warranty?

A: One-year warranty.

 

Q: Does any certificates can be provided?

A: Yes, it depends on what product you request, please check details with us.

 

 

Hot Products

Proline Promag PTFE Liner Electromagnetic Flowmeter 5P2B1F-AAACCAEA1K0A​ 5P2B1F-AAACCAEA1K0A Proline ...
Proline Promass Coriolis Flowmeter 8F2B80-BBEEBASAABSA+AADCJBJC 8F2B80-BBEEBASAABSA+AADCJBJC Proline ...
230VAC E&H Instrument CM442 CM442-AAM1A2F010A+AA Transmitter CM442-AAM1A2F010A+AA 1-/2-Channel ...
CLS21D E&H Instrument Digital Conductivity Meter Condumax CLS21D-C1E1 Digital Conductivity Sensor ...
25bar 2.5MPa E&H Instrument Absolute And Gauge Pressure Cerabar PMP23 PMP23-AA1U1RBWSJ+QJ Absolute ...
HART 4 Channel Transmitter Liquiline CM444 Enclosed Cable Entry CAM21A3FG11BAA 4-Channel Transmitter ...