Home Companies Shanghai I Fluid Technology Co., Ltd.

Dirty water / Slurry flow meter electromagnetic with Accuracy 0.5% Electrode 316L

Shanghai I Fluid Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 811-Building 143, No. 1399 Husong Road, Shanghai, China

Contact name:Yuan

Inquir Now

Shanghai I Fluid Technology Co., Ltd.

Dirty water / Slurry flow meter electromagnetic with Accuracy 0.5% Electrode 316L

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

Turbine flow measurement for Slurry flow meter, dirty water, 2" - 48"

 

Product Description

The electromagnetic flow meter includes both 4-20mA and pulse output. The transmitter can be mounted either integrally to the flow sensor or remotely. The transmitter features a three-line LCD that displays the flow total, flow velocity, flow rate percent of range, and alarm settings. A four-button keypad is used to change settings. There are 27 flow unit options to choose from programmed into the transmitter.

This magmeter is available in sizes from 1 to 24 inches (other sizes are available upon request). The magnetic flowmeter has no parts to obstruct flow resulting in no pressure loss and the 0.25% accuracy is not affected by temperature, pressure, viscosity, density or flow profile. With no moving parts, practically no maintenance is required. The chloroprene rubber sensor liner is suitable for liquid temperatures from -13 to 176°F and is compatible with most water-based fluids and many chemicals. Contact us for additional chemical compatibility information.

 

Work theory

This technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns.

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have.

 

Features

  • anti abrasive hard rubber lining material
  • electric conductivity of medium can be used for detection of product change.
  • no additional pressure loss magnetic flow meter.
  • no moveable parts and long working life.
  • site digital LCD displays instantaneous flow, accumulative flow, flow rate.
  • various output method, like 4-20mA, 0-5V, RS485 and pulse.
  • compact, split and plug-in types optional.
  • change the grounding as the third electrode.
Specifications
Itemslurry flow meter
Applicable pipe sizeDN 15-800 (1/2'' to 31-1/2'')
Applicable medialiquid with conductivity > 5 uS / cm
Accuracy0.5%FS, 1.0%FS
Process connectionflange, ANSI / GB / JIS, 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional
Processing temperature-20 to 150°C, according to lining material
Ambient condition-40 to 80°C, relative humidity <95%
Power supplyAC220V, 50Hz / DC24V / battery
Displaybacklight LCD
Operation4 light touch buttons
Signal output4-20mA, loading resistance 750Ω,
pulse, 0-3kHz, 5V,
RS485
Consumption<8W
Cable inlet/outletM20*1.5
Protectiontransducer IP68, converter IP65
Tube materialcarbon steel, stainless steel optional
Lining materialPTFE, rubber, polyurethane, F46, Fs optional
Electrode materialstainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional
Groundingmade into a third electrode, same material with electrode
Industrieschemical, environmental, metallurgical, pharmaceutical, papermaking, water supply and drainage, etc.
Main performances of the lining materials
Lining materialMain PerformanceApplications
Teflon1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates.
2.Not be perfect in abrasion resistance.
Strong corrosive mediums such as strong acid and alkali
F461.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.
1.The same as PTFE.
2.Applicable in mediums of low abrasion.
Neoprene1.Be of good elasticity, retractility and abrasion resistance.
2.Be resistant to low acid, alkali and salt but not for oxidation mediums.
Water, sewage and slurry, mineral serosity of low abrasion.
Polyurethane1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic impregnants.
Applicable in mineral serosity, slurry and coal slurry of high abrasion.
Main performances of the electrode materials
Electrode materialApplications
Stainless steel SS316Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc.
Hastelloy B(HB)Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt.
Hastelloy C(HC)Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water
TitaniumApplicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion.
TantalumHaving strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali.
Platinum-iridiumAlmost be applicable in all chemical mediums except for aqua fortis, ammonium salt.


Production

 

Hot Products

Residential cold water meter by multi jet water meter, ISO4064 Class B, Brass house Description This ...
Multi jet dry type water meter for residential utility water metering, removable register DN15 - ...
Multi jet water meter with dry dial register for residential utility metering DN15 Brass General ...
Residential water meter by multi jet water meter, dry dial register, ISO4064 General Description The ...
Vertical type Multi jet water meter, dry dial register, magnetic drive DN15 - DN40 Products ...
Multi jet water meter residential water utility, dry dial register, brass house, magnetic drive DN15 ...