Home Companies Shanghai I Fluid Technology Co., Ltd.

Class B Commercial Multi Jet Water Meter ISO 4064 Magnetic Drive Low Head Loss

Shanghai I Fluid Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 811-Building 143, No. 1399 Husong Road, Shanghai, China

Contact name:Yuan

Inquir Now

Shanghai I Fluid Technology Co., Ltd.

Class B Commercial Multi Jet Water Meter ISO 4064 Magnetic Drive Low Head Loss

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

Combination Woltman Water Meter combined with multi jet water meter, magnetic driven


Magnetic drive Combination Woltman Water Meter combined with multi jet water meter

APPLICATION

For measurement of high flows of cold potable water passing through the pipeline.

 

FEATURES

  •  Wide measuring range: From Qmin of the small caliber water meter to Qmax of the large caliber water meter
  •  As a dry meter, deposits in the register are avoided. This ensures a clear reading in long term service.
  •  The main register may rotate more than 360 degreesfor easily reading in any position.
  •  Low head loss.
  •  Lower starting flow.
  •  Novel structure, simple maintenance.
  •  Can be equipped with reed switch option.
  •  Particularly suited in commercial, institutional places of assembly and facilities with fluctuating usage and flow rates.

.WORKING PRINCIPLE

  •  A changeover spring valve diverts flow to the appropriate meter, opening or closing according to pressure variations by changes in flow rate.
  •  At low flow rate, the changeover valve closes and only the small meter in operation 2 water flows through the bypass meter, and the usage is recorded on its register.
  •  When the flow rate increases, pressure is exerted on the large meter, until the flow rate reaches approximately one half the capacity of the bypass meter.
  •  At this point, the drop in pressure causes the valve to open 1, and water flows through both the main meter and bypass meter, and the overall consumption is read by combining the main and bypass registers.
  •  When flow is decreasing, the process in reversed. The valve is closed and water flows through the small meter.

CONSTRUCTION

  •  The meter model LXF-50-200 combines a large caliber water meter (model LXLC-B) on the main line, a small water mete (model LXSC-E) on the bypass line, and a flow changeover valve.
  •  Annotation: LXLC-B removable element woltman water meter.

LXSC-E multi-jet dry type vane wheel water meter.

 

WORKING CONDITION

  •  Water temperature: ≤40℃
  •  Water pressure:≤1.6Mpa

MAXIMUM PERMISSIBLE ERROR

  •  In the lower zone from Qmin inclusive up to but excluding Qt is±5%b)
  •  In the upper zone from Qt inclusive up to and including Qs is ±2%

INDICATION

  •  Cubic meter(m3) and U.S. gallon (USG) for selecting

INSTALLATION

  •  The meter must be installed with the direction of the flow as indicated by the arrow cast in the meter body.
  •  A horizontal position with the register face upwards is recommended.
  •  The meter must have 10 diameters straight pipe ahead of the meter and 5 diameters straight pipe after to insure proper flow through the meter.
  •  The valves must be installed in the front and the back of the water meter.

ATTACHMENT

  •  With every water meter, there will be two flange gaskets.
  •  If you need the connecting flanges(two pieces), please specially request that.

No.NameQtyNo.NameQtyNo.NameQty
1Body(mainwatermeter19Adapting flange117Bolt2
2LXLC-B except for the body110Coupling gasket 2118Bypass meter (LXSC-E)1
3Flat washer811Bolt219Nut3
4Bolt812Flat washer220Coupling 21
5Flange o-ring113Street elbow 2121Coupling o-ring1
6Changeover vale114Coupling gasket322Street1elbow111with1non-return valve1
7Spring washer815Connecting plate123Coupling 11
8Nut816Spring washer224Coupling gasket 11

 

MAIN TECHNICAL DATA COMFORMS TO Q/ZN 184-2003(company standard)

TypeSize(mm)qs
Max Flow
qp
Nominal Flow
qt
Transitional Flow
qmin
Min. Flow
Min.
Reading
Max.
Reading
m3/hm3
LXF-8080mmx20mm80400.200.050.0001999999+99999
LXF-100100mmx20mm120600.200.050.0001999999+99999
LXF-150150mmx40mm3001500.800.200.001999999+99999

 

DIMENSIONS AND WEIGHTS

TypeSize
DN
Length
L
Width
W
Height
H
Height
G
Connecting flangeWeight
kg
mmD
Outer dia.
D1
Bolt cirle dia.
Connecting Bolt
nxM
LXF-8080mmx20mm3703102764002001608XM1627.5
LXF-100100mmx20mm3703202864002201808XM1633
LXF-150150mmx40mm5004453455002852408XM2064

Typelncr easingopen flow rate(m3/h)Decr easingClose flow rate(m3/h)
LXF-801.80.8
LXF-1002.11.2
LXF-1506.04.2


Hot Products

Impeller Type DN25 Multi Jet Water Meters / Single Jet Water Meter With Pulse Output The dry dial ...
DN40 Turbine Hot Water Meter Multijet Water Meters With Totalizer / Flow Rate The dry dial water ...
Multi jet water meter for residential, pulse emitter in remote reading, DN15 thread, brass housing, ...
Multi jet water meter for clean water utility billing, DN20 thread, R 100, Brass housing, PN16 ...
Slurry and waste water flow meter by electromagnetic flowmeter DN100 Liner Rubber Description: The ...
sewage flow meter payable by magnetic flowmeter Dia: DN150 Liner: rubber Product description: The ...