SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD |
High Performance Industrial Water Cooling Towers With DN 50 Mm Discharge Pipe
Description
1.closed cooling towers are Using the counter flow cooling way; few
cooling blind area, high thermal efficiency:
2. Efficiency of cooling tower is to adopt the professional and
efficient water collector to control the running floating rate
,that is less or equal to 0.001%;
3.Closed cooling tower in high air duct design to make sure the
equipment to meet the demand of cooling air flow rate during
operation;
4. Reduce the occupied area compare to other types of cooling tower
to meet the users' space demanding;
5. The tank of cooling tower adopts closed loop, eliminate clutters
go into the tower body to produce spraying blocked;
6. The important part of counterflow cooling tower is the cooler
that uses the antifreeze energy-saving design, to ensure the
circulating water drain up and avoid freezing in the northern
region with low temperature;
7. Design two-circuit cycle according to the demands of custom's
devices, even if one circulation failure, anther cycle can be still
normally operating;
8. The cooling tower design of units are elegant appearance,
automatic digital display, easy to maintain.
Item
FBN-300T Specifications | |
Heat Reject | 1635kw |
Nominal Flow Rate | 300 m3/h |
Work Flow Rate | 235 m3/h |
Fan Power | 2×11kw |
Wind Flow Rate | 2×120000m3/h |
Spray Pump Power | 7.5kw |
Spray Water Flow Rate | 172m3/h |
Spray Pump Raise | 9.6m |
Inlet/Outlet Diameter | DN 200mm |
Makeup Connection | DN40 (Please specify adopted screw standards) |
Bleed Line Diameter | DN50 (Please specify adopted screw standards) |
Net Weight | 5150kg |
Operate Weight | 9500kg |
Dimensions | 5100×2300×4950mm |
Main Features
1) Whole suit, it will convenient for customers to operate, and easy to transportation & installation..
2) structure is compact, installation area is less, and also more space is saved to enlarge the coils’ unit heat rejection area.
3) Energy efficient and environmental protection.Running in a high automatization and intellectualization,no pollution.
4) apply to the low cooling temperature(Temp.<45℃ or not higher than the location wet bulb temperature too much )or needs a small cooling range projects (△T=5-10℃)
5) Professional and serious attitude, and attention to detail is the pursuit of supremacy consistent high quality standards, production, products and services. This COUNTER FLOW mini cooling towerused for smelting furnace.
Product Application
1. Cooling Tower +Heat Exanger Combination
Closer approach to wet bulb temperature and reduce fouling, highly improve process efficiency
2. Air-Cooled Systems
10-20°C lower process temperatures ,less required space and lower energy consumption
3. Once –Through Systems
Reduces environmental impact ,saving up to 95% of the cooling water
4. Reduced installed Cost And Space Requirements
Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity.