Two-Zone Industrial Test Chamber With Large Capacity And Temperature Uniformity

 

Two-Zone Thermal Shock Chamber consist of high temperature zone, low temperature zone. The test sample is in static mode. While Two Zone Thermal Shock Chamber consist of high temperature zone, low temperature zone only. And the test sample is moving up and down along with the built in air-controlled hanging basket.

 

 

Application:

 

Thermal Shock Chamber is ideally designed for testing most commercial products to see how they withstand drastic temperature changes, a harsh condition that subject a product to the most extreme temperature conditions, instantly.Some times with liquid nitrogen cooling if request more strictly temperature. Thermal shock test is used as a vital method to quality inspection for all types of electronic products, electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical, building materials, medical and aerospace industries.And the purpose of testing a product under these circumstances by a thermal shock chamber is to observe changes in the products characteristics and check for failure occurrence of different materials and thermal expansion coefficients. So be sure that these thermal shock chambers are prohibited to flammable explosive easily to volatile substances sample test or storage, corrosive substance sample testing or storage, biological sample test or storage, strong electromagnetic emission source sample test.

 

Data Sheet of Thermal Shock Test Chamber

 

ModelMTS-050MTS-080MTS-150MTS-200MTS-300
Test box dimensions
W * H * D
35*40*3650*40*4060*50*5065*50*6290*50*67
Carton size
W * H * D
135*175*137140*180*137150*185*150155*185*165180*185*170
Preheating temperature+60~+200℃
Pre-cooling temperature-78℃~0℃
Test temperature60℃~+150℃
-10℃~40℃;10℃~65℃
PerformanceTemperature fluctuation±0.5℃
Temperature conversion time5min
Preheating box heating time150150150150150
min3040404040
Pre - cooling box cooling time-40,-55,-65-40,-55,-65-40,-55,-65-40,-55,-65-40,-55,-65
min70,80,9070,80,9070,80,9070,80,9070,80,90
MaterialShellHigh - strength cold - rolled steel plate double - sided powder baking
Inner wallsus#304 stainless steel 2B panel
Insulation MaterialsGlass fiber + polyurethane foam
SystemFansHigh-temperature me, low-temperature me, test chamber with different power and speed centrifugal fan
HeaterHigh-quality nickel-chromium alloy heater
Cooling SystemFrance imports all closed or German imports semi-hermetic compressors. Binary cascade refrigeration + finned evaporator + pure aluminum cold accumulator
ControllerOriginal imported from Japan 7 "TFT touch screen
AccessoriesShelf 2, Lead hole $ 50mm 1 (optional), Recorder (optional)
Protective deviceNo fuse switch, compressor overpressure, overheating, over-current protection, fuses, water flow protection. Phase sequence protection, oil pressure protection, pressure relief protection. Low pressure protection, pneumatic cylinder protection, temperature limit protection.
Electric power(k.w)AC3 380V,50Hz
20,21,2220,21,2222,23,2528,38,4530,40,50

 

 

Features:

 

1.Circulating wind selection: Patio air supply or variable speed motor
If your product has special requirements for air supply wind speed, this program is your best choice.

2.Water supply system selection: RO reverse osmosis
Our equipment to do the humidity, the use of pure water, that this automatic way to make water without interruption to provide pure water, so as to achieve easy and convenient results.

3.Polymer membrane / runner dehumidification system
If long-term low-temperature and low-humidity test conditions are required, then the cellular dehumidification system is an option, and the Humidity Range is required to achieve 10 ° C / 10% RH or less.

4.LN2/LCO2
We provide complete specifications from the United States imports of professional LN2 / LC02 solenoid valves and related control systems to achieve your rapid cooling temperature of the test requirements.

5.Ultrasonic cooling humidification system
If you have to carry out a dynamic test of high heating load under high temperature and high humidity, the ultrasonic cooling and humidification system is meeting the important requirements of this strict requirement.

6.Added glass inner door and hand operated hole
For the often need to test the movement of objects and start. (125mm * Ea) can be added to the glass door to avoid the impact of the door opening on the test environment.

7.Instant access to test data recorder
When the need to test the environment at the same time and the temperature of the multi-point measured object temperature measurement records, increased load specification recorder is the only choice to achieve the demand.

8.Computer connection operation recording software
When the software for the R & D of Metrology 's ring testing machine, its powerful function can monitor and control the machine at the same time, access to the information in the machine, providing the most convenient

 

Structure technology

1.Company hardware equipment Imports of German laser laser machine 1; Title of the AMADA AIRS-255NT punching and a Taiwan; Germany for all types of carbon dioxide welding machine and argon welding machine more than 10 Autodrsk inventor 3D graphics software, 3D sheet metal demolition and design of virtual assembly.
2.Shell made of high quality galvanized steel, electrostatic powder coating to be paint;
3.The inner box is made of imported SUS # 304 stainless steel, with full welding process to prevent leakage and penetration of high temperature and high humidity air inside the box; inner liner fillet design of inner box can better discharge condensate of side wall.
 
 
Control circuit technology

1. Power distribution layout According to the technical department of the distribution assembly plans to install electrical components used internationally renowned brands: Omron, Schneider, Germany phoenix terminals, line code clearly marked.
Selection of the old domestic brand, (Zhujiang cable) to ensure that the quality of the wire; control line minimum 0.75 square RV soft copper wire, all the major load such as motor compressors are based on EC trunking safety current standard trapping trail selection! Compressor cable box cable mouth with sealant processing, to prevent frosting junction box terminal short circuit.
All terminal screws are connected to the standard fixed torque, to ensure reliable fastening to prevent loose ignition and other hidden dangers!
 
 
 
 
Refrigeration Technology

3D refrigeration system management drawing
Variable Frequency Control Technology of Refrigeration System

In the frequency conversion refrigeration system, even if the power frequency 50HZ is fixed, can change the
frequency through the frequency changer, thus adjusts the compression rotational speed, causes the cold quantity
continuously to change, guarantees the compressor movement load in the test box the actual load to match (namely
test body temperature Increase, the compressor frequency to rise, improve the cooling capacity, on the contrary, the
compressor frequency to reduce and reduce the cooling capacity) greatly saves the unnecessary loss of operation to achieve energy-saving purposes. In the beginning of the test chamber can also run by increasing the frequency of the compressor to improve the capacity of the cooling system to achieve the purpose of rapid cooling.
The chamber adopts frequency conversion refrigeration system, which can precisely control the temperature of the box body, make the temperature of the box body constant, the temperature fluctuation is small, and the suction and discharge pressure of the refrigeration system is stable and the compressor runs stably and reliably. Electronic expansion flow servo.
 
Refrigeration system technology Other energy - saving technologies

A) The use of PID + PWM principle VRF technology (electronic expansion valve according to the thermal conditions of flow control)
Low-temperature working state, the heater does not participate in the work, through the PID + PWM regulation of the cooling (cooling capacity of the air flow control system); low-temperature working conditions, the use of the principle of PID PID VRF technology (refrigerant flow control) Flow rate and flow direction of the cooling pipe, cold side of the pipeline, heat the next three-way flow pipe to adjust to achieve the work of the temperature is automatically constant, this method in low temperature conditions, the studio can automatically achieve a constant temperature, Low temperature conditions, can achieve a 30% reduction in energy consumption. The technology is based on Danfoss ETS system electronic expansion valve, can be applied to different cooling capacity requirements of the cooling adjustment, both at different cooling rate requirements, to achieve the compressor cooling capacity adjustment.
B) the size of two sets of compressor design technology, according to load conditions automatically start and stop (large series is designed)
The refrigeration unit is equipped with a set of semi-hermetic compressors composed of binary cascade refrigeration system plus a full-density single-stage refrigeration system. Configure the mother; according to the load conditions inside the box and the cooling rate of intelligence to open the different compressor groups, so that the cooling capacity of the box and the compressor output power to achieve the best match, in order to achieve the best operating conditions in the compressor section circle to Extend the service life of the compressor. More importantly, a large set of traditional design compared to the energy-saving effect is very obvious, you can achieve more than 30% of the temperature control. With VRF technology)

 

 

 

 
 
 
 
 
 
 

Hot Products

Low Humidity And Low Temperature 5°/5%RH Constant Temperature Humidity Chamber With Double Anti...
Low Humidity And Low Temperature 5°/5%RH Test Chamber With Low Noise And Advanced Energy Saving ...
SUS304 Sand and Dust Environmental Test Chamber 512-1500 Liters Product Description The purpose of ...
Advanced Energy Saving Design Thermal Shock Testing Chamber With Low Noise And SUS#304 Stainless ...
Lab Temperature SUS#304 Interior Climatic Test Chamber Compact Modular , ESS Product Presentation ...
Advanced Energy Saving Design Thermal Shock Testing Chamber With Low Noise And SUS#304 Stainless ...