Home Companies Zhejiang KRIPAL Electric Co., Ltd.

GMC AC/DC Mini Contactor Motor Protection Switch Low consumption 6A,9A,12A,16A

Active Member

Contact Us

[China]

Address: Daqiao Industrial Zone, Baixiang Town,Yueqing 325603,Zhejiang, China

Contact name:Jessica

Zhejiang KRIPAL Electric Co., Ltd.

GMC AC/DC Mini Contactor Motor Protection Switch Low consumption 6A,9A,12A,16A

Country/Region china
City & Province zhejiang
Categories Grain

Product Details

 

GMC AC/DC Mini Contactor Motor Protection Switch Low consumption 6A,9A,12A,16A

 

 

AC Contactors (Magnetic Contactor) provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instruments and equipments against overload currents by using thermal relays, for capacitor switching contactor.

 

While switching on a capacitive circuit, a high frequency and large transient current peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of suitable contactors the compensating current must be take into consideration for 50kVAR and above, and for less than 50kVAR can be omitted.

 

 

Description:

 

Directly drive contactor by transistor output of PLC

 

The power consumption of the UKC1- low consumption type contactor is 1.2W.

 

This contactor can be driven by a transistor output of a PLC or electronic equipment such as photoelectric switch, or a proximity limit switch. Therefore, it is possible for this contactor to directly interface without interface relay for driving a 3-phase induction motor.

 

Low coil power consumption greatly expands application flexibility. Standard AC coils require 1.8 watts.

 

 

 

 

AC Specifications:

 
Rated current AC3(IEC60947AC1 IthAux. ContactsType
220-240V380-440V550-550V690V
6A1.5KW  7A2.2KW  6A3KW      5A3KW      4A20A1NO or 1NCUKC1-6M
9A2.2KW  9A4KW      9A3.7KW  6A4KW      5A20A1NO or 2NCUKC1-9M
12A3KW    12A5.5KW    12A4KW      7A4KW      55A20A1NO or 3NCUKC1-12M
16A4KW    15A7.5KW    16A5.5KW    9A4KW    5A20A1NO or 4NCUKC1-16M
 
AC coil Voltage (50/60Hz): 24, 36, 42, 48, 110, 115, 120, 127, 220/208, 220, 220/230, 230/240, 256, 277, 380/440, 400, 440, 480, 500, 550
 
Characteristics(440VAC)
Rated current6A9A12A18A
Short circuit current(max)380V6090120160
660V72108144180
Breaking current(max)380V487296128
660V6090120150
Operation cycles per hourAC-31800180018001800
AC-4300300300300
electrical life time      (10, 000 times)AC-3100100100100
AC-420202020
Machanical Life time(1000 times)1200120012001200
Aux contactsStandard configuration1NO1NO1NO1NO
Top mointingAU-2M/4MAU-2M/4MAU-2M/4MAU-2M/4M
Panel Installationguid screwguid screwguid screwguid screw
 
Characteristices of the coil
Coil voltageAC
coil consumption(VA)2
Pick-ip32va
Maintain6va
Selections of pick-up voltage(%)80-110
Selections of droup-out voltage(%)30-40
Pick-up times10-20
droup-out times35-45
 


Coil voltage(AC): 


24V,36V,  42V, 48V, 110V, 115V, 120V, 200V, 220V, 240V, 256V, 277V, 380V, 400V, 440V,  480V, 500V, 550V 
 

 

Benefits for mini AC contactors:

 

Low consumption power

Saving panel size

Installation space is reduced to 50% of conventional DC operated contactors achieving high performance.

 

 

Main application fields for ac mini contactors: 

 

Lighting for out-door

Car washing facilities

Crain hoist

Lighting of sports facilities

Pump

Compressor

Vending machine

Painting machine

Show case

It is possible to expand the control wire length since voltage drop in wires is small.

 

 

Application:

 

 

Contactors are used to control electric motors, lighting, heating, capacitor banks, thermal evaporators, and other electrical loads.

 

Lighting control

Contactors are often used to provide central control of large lighting installations, such as an office building or retail building. To reduce power consumption in the contactor coils, latching contactors are used, which have two operating coils. One coil, momentarily energized, closes the power circuit contacts, which are then mechanically held closed; the second coil opens the contacts.

 

 

Normal working conditions and installation conditions

 

Contactor electric ratings: AC 50/60Hz, 690V, up to 95A
Utilization category: AC-3, AC-4
Altitude: ≤2000m
Ambient temperature: -5-40º C
Mounting category: III
Mounting conditions: inclination between mounting plane
Vertical plane should not exceed ±5°
Standards for AC contactor: IEC/EN 60947-4-1. IEC/EN 60947-5-1

Hot Products

Surface Mounted 32A Rotary Isolator Switch 4 Pole / Electrical Isolation Switch KRIPAL HAS THE ...
3 Position 20 Amp Rotary Isolator Switch Electrical Disconnect Switch 3 Pole 10A KRIPAL HAS THE ...
IP65 100A 4 Pole Stainless Steel Enclosed Multi Position Rotary Switch Disconnectors Kripal is the ...
Miniature Solar PV 25A Power Isolation On Off Rotary Disconnect Switch IP66 Description: UKPD series ...
IP65 100A 4 Pole Painted steel Enclosed Multi Position Rotary Switch Disconnectors Kripal is the ...
High quality 1000V DC Rotary Isolator Switch with black handle Generally Speaking,the voltage on DC ...