New Yaskawa Electric 4.0A 2.63N.m AC SERVO MOTOR 550W
SGMDH-06A2A-YR25
Specification
Brand/Manufacturer | Yaskawa Electric |
Model | SGMDH-06A2A-YR2 |
Product Type | AC Servo Motor |
Rated Output | 550W |
Rated Torque2.63 | Nm |
Rated Speed | 3000RPM |
Power Supply Voltage | 200vAC |
Rated Current | 4.0A |
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
SIMILAR PRODUCTS
SGMDH-056A2A-YR25 | SGMDH056A2AYR25 SERVO MOTOR | yaskawa |
SGMDH-06A2 | SGMDH06A2 SERVO MOTOR | yaskawa |
SGMDH-06A2A-TR25 | SGMDH06A2ATR25 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR | SGMDH06A2AYR SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR11 | SGMDH06A2AYR11 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR12 | SGMDH06A2AYR12 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR13 | SGMDH06A2AYR13 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR14 | SGMDH06A2AYR14 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR24 | SGMDH06A2AYR24 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR25 | SGMDH06A2AYR25 SERVO MOTOR | yaskawa |
SGMDH-06A2A-YR26 | SGMDH06A2AYR26 2.63NM 550W 4AMP 2000RPM 200V | yaskawa |
SGMDH-12A2 | SGMDH12A2 SERVO MOTOR | yaskawa |
SGMDH-12A2A-YA14 | SGMDH12A2AYA14 SERVO MOTOR | yaskawa |
SGMDH-12A2A-YR | SGMDH12A2AYR SERVO MOTOR | yaskawa |
SGMDH-12A2A-YR12 | SGMDH12A2AYR12 SERVO MOTOR | yaskawa |
SGMDH-12A2A-YR13 | SGMDH12A2AYR13 AC 2000RPM 1150W 200V 7.3AMP 5.49NM | yaskawa |
SGMDH-12A2A-YR14 | SGMDH12A2AYR14 SERVO MOTOR | yaskawa |
SGMDH-12A2A-YR15 | SGMDH12A2AYR15 SERVO MOTOR | yaskawa |
SGMDH-12A2A-YR21 | SGMDH12A2AYR21 SERVO MOTOR | yaskawa |
SGMDH-12A2A-YRA1 | SGMDH12A2AYRA1 SERVO MOTOR | yaskawa |
SGMDH-13A2A-YR23 | SGMDH13A2AYR23 SERVO MOTOR | yaskawa |
SGMDH-20A2A21 | SGMDH20A2A21 SERVO MOTOR | yaskawa |
SGMDH-22A2 | SGMDH22A2 SERVO MOTOR | yaskawa |
SGMDH-22A2A-YR11 | SGMDH22A2AYR11 SIGMA II 2.2KW L/U AXIS SK45X | yaskawa |
SGMDH-22A2A-YR12 | SGMDH22A2AYR12 SERVO MOTOR | yaskawa |
SGMDH-22A2A-YR13 | SGMDH22A2AYR13 SERVO MOTOR | yaskawa |
SGMDH-22A2A-YR13YA | SGMDH22A2AYR13YA SERVO MOTOR | yaskawa |
SGMDH-22A2A-YR14 | SGMDH22A2AYR14 SERVO MOTOR | yaskawa |
Installation method:
a) Install Servopack perpendicular to the wall so that the front
panel (containing connectors) faces outward.
b) Provide sufficient space around each Servopack to allow cooling
by natural convection.
c) When installing Servopacks side by side, provide at least 10 mm
space between them and at least 50 mm space above and below them as
shown in the figure above. Install cooling fans above the
Servopacks to prevent the temperature around each Servopack from
increasing excessively and also to maintain the temperature inside
the control panel evenly.
d) Maintain the following conditions inside the control panel:
• Ambient temperature for Servopack: 0 to 55°C
• Humidity: 90%RH or less • Vibration: 0.5G (4.9 m/s2)
• Condensation and freezing: None • Ambient temperature to ensure
long-term reliability: 45°C or less
<1> Remove the jumper when installing an optional DC link
choke.
<2> The MC on the input side of the main circuit should open
when the thermal relay is triggered.
3.2 Standard Connection Diagram
34 YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000
Technical Manual
<3> Self-cooled motors do not require separate cooling fan
motor wiring.
<4> Connected using sequence input signal (S1 to S5) from NPN
transistor; Default: sink mode (0 V com).
<5> Use only a +24 V internal power supply in sinking mode;
the source mode requires an external power supply. Refer to I/O
Connections on page 47 <6> Minimum load: 5 Vdc, 10 mA
(reference value).
<7> Monitor outputs work with devices such as analog
frequency meters, ammeters, voltmeters and wattmeters; they arenot
intended for use as a feedback-type of signal.
WARNING! Sudden Movement Hazard. Do not close the wiring for the
control circuit unless the multifunction input terminal parameter
is
properly set (S5 for 3-Wire; H1-05 = “0”). Improper sequencing of
run/stop circuitry could result in death or serious injury from
moving equipment.
WARNING! Sudden Movement Hazard. Ensure start/stop and safety
circuits are wired properly and in the correct state before
energizing the drive. Failure to comply could result in death or
serious injury from moving equipment. When programmed for 3-Wire
control, a momentary
closure on terminal S1 may cause the drive to start.
WARNING! When 3-Wire sequence is used, set the drive to 3-Wire
sequence before wiring the control terminals and ensure parameter
b1-17 is set to 0 (drive does not accept a run command at power up
(default). If the drive is wired for 3-Wire sequence but set up for
2-Wire
sequence (default) and if parameter b1-17 is set to 1 (drive
accepts a Run command at power up), the motor will rotate in
reverse direction at power up of the drive and may cause injury.
Figure 3.2 illustrates an example of a 3-Wire sequence.
Type No. Signal Name Description Signal Level
Digital input signals
S1 Forward run/stop command Forward run when CLOSED; stopped when
OPEN.
24 Vdc, 8 mA
Photocoupler isolation
S2 Reverse run/stop command Reverse run when CLOSED; stopped when
OPEN.
S3 External fault input Fault when CLOSED.
Multi-function digital inputs
Functions set by H1-01 to H1-05.
S4 Fault reset Reset when CLOSED
S5 Multi-step speed reference 1
(Master/auxiliary switch)
Auxiliary frequency reference when CLOSED.
S6 Multi-step speed reference 2 Multi-step setting 2 when CLOSED.
S7 Jog frequency reference Jog frequency when CLOSED.
SN SC Digital input common Refer to Table 2.10 for connection
details.
SP Analog input signals
+V +15Vdc power supply +15Vdc power supply for analog inputs or
transmitters +15Vdc
(Max. current: 20 mA) A1 Analog input or Speed Command 0 to
+10Vdc/100% 0 to +10 V(20 kΩ)
A2 Multi-function analog input 4 to 20 mA/100% 0 to
+10Vdc/100% (H3-0
Function set by H3-09.
4 to 20 mA(250Ω)
0 to +10 V(20kΩ)
AC Analog common – –
E(G) Shield wire, optional ground
line connection point – –
Digital output signals M1
During Run (N.O. contact) CLOSED during operation
Multi-function digital output
Function set by
H2-01. Dry contacts
Contact capacity:
1 A max. at 250Vac
1 A max. at 30Vdc
Remote/Auto Operation
(N.O. contact) CLOSED when local control
Multi-function digital output
Function set by M4 H2-02.
Fault output signal (SPDT)
MA/MC: CLOSED during fault condition
MB/MC: OPEN during fault condition
Dry contacts
Contact capacity:
1 A max. at 250Vac
1 A max. at 30Vdc
Analog output signals
FM Multi-function analog output (output frequency)
0 to +10Vdc/100% frequency
Multi-function
analog monitor 1
Function set by H4-01
0 to +10Vdc max. ±5%
2 mA max. AC Analog common –
AM Multi-function analog output (output current) 0 to +10Vdc/100%
Drive's rated
output current
Multi-function analog monitor 2
Function set by H4-04 RS-485/ 422 R+ Modbus communication input For
2-wire RS-485, jumper R+ and S+ and jumper R- and S-.
Differential input, R- PHC isolation S+ Modbus communication
output
Differential input, S- PHC isolation