OMRON R88D-KN50H-ML2 AC Servodriver , MECHATROLINK-II , Three Phase 200 VAC , 5kW

Country/Region china
City & Province shenzhen guangdong
Categories Solar Chargers
InquireNow

Product Details

OMRON R88D-KN50H-ML2 AC Servodriver , MECHATROLINK-II , Three Phase 200 VAC , 5kW

 

 

AC Servo Drives

General Specifications

 

ItemSpecifications
Ambient operating temperature and operating
humidity
0 to +55C, 85% max. (with no condensation)
Storage ambient temperature and humidity-20 to +65C, 85% max. (with no condensation)
Operating and storage atmosphereNo corrosive gases
Vibration resistance10 to 60 Hz and at an acceleration of 5.88 m/s2 or less (Not to be
run continuously at the resonance point)
Insulation resistanceBetween power supply terminal/power terminal and FG terminal:
0.5 MΩ min. (at 500 VDC Megger)
Dielectric strengthBetween power supply/power line terminals and FG terminal:
1,500 VAC for 1 min at 50/60 Hz
Protective structureBuilt into panel
International
standard
EC directivesEMC directiveEN55011, EN61000-6-2, IEC61800-3
Low voltage
directive
EN61800-5-1
Machinery
directives
EN954-1 (Cat.3), EN ISO 13849-1: 2008 (PLc,d), ISO 13849-1: 2006
(PLc,d), EN61508 (SIL2), EN62061 (SIL2), EN61800-5-2 (STO),
IEC61326-3-1 (SIL2)
UL standardsUL508C
CSA standardsCSA C22.2 No.14
Korean Radio Regulations (KC)Certified

 

 

Note: 1. The above items reflect individual evaluation testing. The results may differ under compound conditions.
Note: 2. Always disconnect all connections to the Servo Drive before you perform insulation resistance tests on it. If you
perform an insulation resistance test while the Servo Drive is connected, the Servo Drive may be damaged.
Never perform dielectric strength tests on the Servo Drive. Failure to follow this precaution may result in
damaging internal elements.
Note: 3. Some Servo Drive parts will require maintenance. For details, refer to the G5 series USER'S MANUAL.
Confirm the Manual No. that is listed in Related Manuals.
 

Servo Driver with 200 VAC Input Power
for Single-phase/Three-phase input type

 

ItemR88D-
KN01H-ML2
R88D-
KN02H-ML2
R88D-
KN04H-ML2
R88D-
KN08H-ML2
R88D-
KN10H-ML2
R88D-
KN15H-ML2
Continuous output current (rms)1.2 A1.6 A2.6 A4.1 A5.9 A9.4 A
Input
power
supply
Main circuitPower supply
capacity
0.5 KVA0.5 KVA0.9 KVA1.3 KVA1.8 KVA2.3 KVA
Power supply
voltage
Single-phase or Three-phase 200 to 240 VAC (170 to 264 V), 50/60 Hz
Rated current1.6/0.9 A *12.4/1.3 A *14.1/2.4 A *16.6/3.6 A *19.1/5.2 A *114.2/8.1 A *1
Heat value *214.3/13.7W *123/19 W *133/24 W *130/35.5 W *157/49 W *1104/93 W *1
Control
circuit
Power supply
voltage
Single-phase 200 to 240 VAC (170 to 264 V), 50/60 Hz
Heat value *24 W4 W4 W4 W7 W7 W
WeightApprox.
0.8 kg
Approx.
0.8 kg
Approx.
1.1 kg
Approx.
1.6 kg
Approx.
1.8 kg
Approx.
1.8 kg
Maximum applicable motor capacity100 W200 W400 W750 W1 kW1.5 kW
Applicable
Servo-
motors
(R88M-)
3,000 r/min
Servomotors
[INC]K05030H
K10030H
K20030HK40030HK75030H-K1K030H
K1K530H
[ABS]K05030T
K10030T
K20030TK40030TK75030T-K1K030T
K1K530T
2,000 r/min
Servomotors
[INC]----K1K020HK1K520H
[ABS]----K1K020TK1K520T
1,000 r/min
Servomotors
[INC]-----K90010H
[ABS]-----K90010T

 

 

Servo Driver with 200 VAC Input Power
for Three-phase input type

 

ItemR88D-KN20H-ML2R88D-KN30H-ML2R88D-KN50H-ML2
Continuous output current (rms)13.4 A18.7 A33.0 A
Input power
supply
Main circuitPower supply capacity3.3 KVA4.5 KVA7.5 KVA
Power supply voltageThree-phase 200 to 230 VAC (170 to 253 V), 50/60 Hz
Rated current11.8 A15.1 A21.6 A
Heat value *1139 W108 W328 W
Control circuitPower supply voltageSingle-phase 200 to 230 VAC (170 to 253 V), 50/60 Hz
Heat value *110 W13 W13 W
WeightApprox. 2.7 kgApprox. 4.8 kgApprox. 4.8 kg
Maximum applicable motor capacity2 kW3 kW5 kW
Applicable
Servomotors
(R88M-)
3,000 r/min
Servomotors
[INC]K2K030HK3K030HK4K030H
K5K030H
[ABS]K2K030TK3K030TK4K030T
K5K030T
2,000 r/min
Servomotors
[INC]K2K020HK3K020HK4K020H
K5K020H
[ABS]K2K020TK3K020TK4K020T
K5K020T
1,000 r/min
Servomotors
[INC]-K2K010HK3K010H
[ABS]-K2K010TK3K010T

 

 

 

Similar Model Products

 

 

SpecificationsModel
Power Model Supply VoltageApplicable Servomotor Capacity
Single-phase
100 VAC
50 WR88D-KNA5L-ML2
100 WR88D-KN01L-ML2
200 WR88D-KN02L-ML2
400 WR88D-KN04L-ML2
Single-phase/three-phase
200 VAC
100 WR88D-KN01H-ML2
200 WR88D-KN02H-ML2
400 WR88D-KN04H-ML2
750 WR88D-KN08H-ML2
1 kWR88D-KN10H-ML2
1.5 kWR88D-KN15H-ML2
Three-phase
200 VAC
2 kWR88D-KN20H-ML2
3 kWR88D-KN30H-ML2
5 kWR88D-KN50H-ML2
Three-phase
400 VAC
600 WR88D-KN06F-ML2
1 kWR88D-KN10F-ML2
1.5 kWR88D-KN15F-ML2
2 kWR88D-KN20F-ML2
3 kWR88D-KN30F-ML2
5 kWR88D-KN50F-ML2

 

 

 

 

 

 

Hot Products

Redundant Power Supply Module Mitsubishi Universal model CPU Q01UCPU 15 k steps Model: Q01UCPU No.of ...
Q02UCPU 2048 points. Redundant Power Supply Module Mitsubishi Universal model CPU Model: Q02UCPU No...
Q03UDCPU Universal model Redundant Power Supply Module Mitsubishi 30 k steps Model: Q03UDCPU No.of I...
Universal model Redundant Power Supply Module Mitsubishi 40 k steps Q04UDHCPU 4096 points Model: ...
Q06UDHCPU Universal model Redundant Power Supply Module Mitsubishi 8192 points 60 k steps Model: ...
4096 points 100 k steps Redundant Power Supply Module Universal model Mitsubishi Q10UDHCPU Model: ...