Home Companies Shenzhen Wisdomlong Technology CO.,LTD

Yaskawa Absolute Encoder Plug-in UTSAH-B17BBF For SGMDH-45A2AB ready to be installed

Shenzhen Wisdomlong Technology CO.,LTD

Contact Us

[China] country

Trade Verify

Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China

Contact name:Eva

Inquir Now

Shenzhen Wisdomlong Technology CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Yaskawa Absolute Encoder Plug-in UTSAH-B17BBF For SGMDH-45A2AB ready to be installed

Country/Region china
City & Province shenzhen guangdong
Categories Solar Chargers
InquireNow

Product Details

Yaskawa Absolute Encoder Plug-in UTSAH-B17BBF For SGMDH-45A2AB ready to be installed

 

 

 

 

 

QUICK DETAILS

  1. Brand :Yaskawa
  2. Model :UTSAH-B17BBF
  3. Place of Origin :Japan

 


DESCRIPTION

  • Servo Motor Encoder
  • Yaskawa Electric
  • Internal encoders

 

 

 

Item specifics
Model Number:UTSAH-B17BBF

Power Supply:DCMotor

Type:Amplifieris_

customized:yes

Install Style:Plug-in

Frequency:High Frequency

Function:Power Triode

Construction:Point Contact

TypeStructure:PNP

Type:AmplifierSpecial

Function:Common Point Contact Diode

 

 

 


OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
Honeywell TC-,TK-GE Modules IC -
Fanuc motor A0-Yokogawa transmitter EJA-
 
 
 
 
 
 
 
SIMILAR PRODUCTS
UTMAH-B12BD8V - Yaskawa - Internal encoders
UTMAHB12BD8V - Yaskawa - Internal encoders
UTMAH-B12BDYR7 - Yaskawa - Internal encoders
UTMAHB12BDYR7 - Yaskawa - Internal encoders
UTMAH-B12BDYR6 - Yaskawa - Internal encoders
UTMAHB12BDYR6 - Yaskawa - Internal encoders
UTMAH-B15AS8F - Yaskawa - Internal encoders
UTMAHB15AS8F - Yaskawa - Internal encoders
UTMAH-B15AS19B - Yaskawa - Internal encoders
UTMAHB15AS19B - Yaskawa - Internal encoders
UTMAH-B15AS4OB - Yaskawa - Internal encoders
UTMAHB15AS4OB - Yaskawa - Internal encoders
UTMAH-B15BS13 - Yaskawa - Internal encoders
UTMAHB15BS13 - Yaskawa - Internal encoders
UTMAH-B15AR - Yaskawa - Internal encoders
UTMAHB15AR - Yaskawa - Internal encoders
UTMAH-B15DSB - Yaskawa - Internal encoders
UTMAHB15DSB - Yaskawa - Internal encoders
UTMAH-B15AS3DB - Yaskawa - Internal encoders
UTMAHB15AS3DB - Yaskawa - Internal encoders
UTMAH-B15AS158 - Yaskawa - Internal encoders
UTMAHB15AS158 - Yaskawa - Internal encoders
UTMAH-B15AS4NB - Yaskawa - Internal encoders
UTMAHB15AS4NB - Yaskawa - Internal encoders
UTMAH-B15AS15B - Yaskawa - Internal encoders
UTMAHB15AS15B - Yaskawa - Internal encoders
UTMAH-B15AS4MB - Yaskawa - Internal encoders
UTMAHB15AS4MB - Yaskawa - Internal encoders
UTOPE-40AWT - Yaskawa - Internal encoders
UTOPE40AWT - Yaskawa - Internal encoders
UTOPE-25ZDL - Yaskawa - Internal encoders
UTOPE25ZDL - Yaskawa - Internal encoders
UTOPE-300WB80 - Yaskawa - Internal encoders
UTOPE300WB80 - Yaskawa - Internal encoder
 
 
 
 
 
 
Installing the Option
Refer to the instructions below to install the option.
1. Shut off power to the drive, wait the appropriate amount of time for voltage to
dissipate, then remove the digital operator (E), front cover (D), and terminal cover
(F). Refer to the Quick Start Guide packaged with the drive.
DANGER! Electrical Shock Hazard. Disconnect all power to the drive and wait at least the amount of time
specified on the drive front cover safety label. After all indicators are off, measure the DC bus voltage to
confirm safe level, and check for unsafe voltages before servicing to prevent electric shock. The internal
capacitor remains charged even after the power supply is turned off.
NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling
the option, drive, and circuit boards. Failure to comply may result in ESD damage to circuitry.
 
 
 
 
Prepare and connect the wire ends as shown in Figure 6 and Figure 7. Refer to
Wire Gauges and Tightening Torques on page 28 to confirm that the proper tightening torque is applied to each terminal. Take particular precaution to ensure
that each wire is properly connected and wire insulation is not accidentally pinched
into electrical terminals.
WARNING! Fire Hazard. Tighten all terminal screws according to the specified tightening torque. Loose
electrical connections could result in death or serious injury by fire due to overheating electrical connections.
Tightening screws beyond the specified tightening torque may result in erroneous operation, damage the
terminal block, or cause a fire.
NOTICE: Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not
contact other wiring. Insufficient insulation may cause a short circuit and damage the option or drive.
 
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 

 

 

 

 

 

Hot Products

Emerson KJ3221X1-BA1 AO, 8-Channel, 4-20 mA, HART Series 2 Redundant Card Redundant Power Supply ...
ABB Redundant Power Supply Module IMASI23 infi 90 AC System Power Supply Module Control Board ...
Q00UJCPU MITSUBISHI Universal Redundant Power Supply Module 100 to 240 V AC input / 5 V DC/3 A ...
Redundant Power Supply Module Mitsubishi Universal model CPU Q01UCPU 15 k steps Model: Q01UCPU No.of ...
Q02UCPU 2048 points. Redundant Power Supply Module Mitsubishi Universal model CPU Model: Q02UCPU No...
Q03UDCPU Universal model Redundant Power Supply Module Mitsubishi 30 k steps Model: Q03UDCPU No.of I...