Home Companies Shenzhen Wisdomlong Technology CO.,LTD

Mitsubishi Electric Variable Frequency Inverter FR-A840-01800-2-60 FR-A800 Series

Shenzhen Wisdomlong Technology CO.,LTD

Contact Us

[China] country

Trade Verify

Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China

Contact name:Eva

Inquir Now

Shenzhen Wisdomlong Technology CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Mitsubishi Electric Variable Frequency Inverter FR-A840-01800-2-60 FR-A800 Series

Country/Region china
City & Province shenzhen guangdong
Categories Solar Chargers
InquireNow

Product Details

Mitsubishi Electric Variable Frequency Inverter FR-A840-01800-2-60 FR-A800 Series

 

 

 

Sepecifications


 

Model:FR-A840-01800-2-60
Input:AC380-480V 50/60Hz
Output:AC380-480Vmax
Brand:Mitsubishi Electric
Country of Origin:CN

 

 

 

FR-A800 Product Details

 

 

The FR-A800 Series is Mitsubishi Electric’s flagship inverter solution that delivers multi-use performance, accuracy and system flexibility in an ultra reliable hardware package designed for industrial use.

  • High Speed Response: With a speed response of 50Hz, FR-A800 to respond to a change in motor load. FR-A800 reacts to a speed signal much faster too – between 2 to 3 ms as opposed to 5 to 20 ms with FR-A700.
  • Wide Speed Range: 200:1 speed range open loop, 1500:1 closed loop speed range.
  • Extended Maximum Speed: A standard FR-A800 VFD can drive high speed motors at up to 590Hz, compared to the FR-A700’s 400Hz.
  • IPM Motor Control: Standard FR-A800 VFDs can drive the new generation IPM (Internal Permanent Magnet) motors, such as the Marathon ‘SyMAX’ series.
  • Safety Stop: FR-A800 is a SAFETY drive. “STO” capability enables SIL2 / PLd category emergency stops.
  • Compatible with USB Stick: VFD settings can be easily uploaded or downloaded and ‘black box’ operating data at the time of a drive trip can be copied for diagnosis using the FR-Configurator software.
  • GOT interface: Automatic connectivity to GOT 2000 series GOTs without the need to change any parameters.
  • Improved PLC: FR-A800 has a new internal PLC based around the Mitsubishi ‘L series’ processor. Instructions in the form of ‘Function Blocks’ can now be used.
  • Conformal Coating: All FR-A800 VFDs have Conformal Coated boards as standard.
  • Separate rectifier stage: For drives over 500 HP – greater system flexibility.

 

 

FR-A800 Ratings 240V Class

 

 

Model NumberAMPS for DutyHorsepower For Duty (NEC)Frame SizeWeight
SLDLDNDHDSLDLDNDHD
FR-A820-00046-1-N64.64.231.510.750.25A5.5
FR-A820-00077-1-N67.7753210.5B5.9
FR-A820-00105-1-N610.59.685321C8.8
FR-A820-00167-1-N616.715.2118532C8.8
FR-A820-00250-1-N6252317.5117.553C8.8
FR-A820-00340-1-N634312417.5107.55D16.7
FR-A820-00490-1-N6494533242015107.5D16.7
FR-A820-00630-1-N663584633201510E20.5
FR-A820-00770-1-N67770.56146252015F37.4
FR-A820-00930-1-N693857661302520F37.4
FR-A820-01250-1-N61251149076403025F37.4
FR-A820-01540-1-601541401159060504030G48.4
FR-A820-01870-1-601871701451156050/6040H92.4
FR-A820-02330-1-60233212175145756050H92.4
FR-A820-03160-1-60 (*1)3162882151751251007560K118.8
FR-A820-03800-1-U6 (*1)38034628821515012510075L162.8
FR-A820-04750-1-U6 (*1)475432346288150125100L162.8

 

Note 1: These drives must be used together with a DC Link Choke, sold separately.

 

 

 

FR-HEL DC Link Chokes (sold separately)

 

Model NumberSLDLDNDHD
FR-A820-03160-1-60FR-HEL-90KFR-HEL-75K--
FR-A820-03800-1-U6FR-HEL-110KFR-HEL-90KFR-HEL-75K-
FR-A820-04750-1-U6FR-HEL-110KFR-HEL-110KFR-HEL-90KFR-HEL-75K

 

 

 

FR-A800 Ratings 480V Class

 

 

Model NumberAMPS For DutyHorsepower For Duty (NEC)Frame
Size
Weight
(lbs) (*4)
SLDLDNDHDSLDLDNDHD
FR-A840-00023-1-N62.32.11.50.8110.50.25C7.7
FR-A840-00038-1-N63.832.51.52210.57.7
FR-A840-00052-1-N65.24.842.533217.7
FR-A840-00083-1-N68.37.66455328.8
FR-A840-00126-1-N612.611.5967.57.5538.8
FR-A840-00170-1-N6171612910107.55D16.7
FR-A840-00250-1-N6252317121515107.516.7
FR-A840-00310-1-N63129231720201510E20.5
FR-A840-00380-1-N6383531232525201520.5
FR-A840-00470-1-N64743383130302520F37.4
FR-A840-00620-1-N6625744384040302537.4
FR-A840-00770-1-607770574460504030G50.6
FR-A840-00930-1-609385715760605040H90.2
FR-A840-01160-1-6011610686717575605090.2
FR-A840-01800-1-60 (*1)18014411086150100756094.6
FR-A840-02160-1-U6 (*1)21618014411015015010075J114.4
FR-A840-02600-1-U6 (*1)260216180144200150150100121.0
FR-A840-03250-1-U6 (*1)325260216180250200150150L156.2
FR-A840-03610-1-U6 (*1)361325260216300250200150171.6
FR-A840-04320-1-U6 (*1)432361325260350300250200M257.4
FR-A840-04810-1-U6 (*1)481432361325400350300250257.4
FR-A840-05470-1-U6 (*1)547481432361450400350300N365.2
FR-A840-06100-1-U6 (*1)610547481432500450400350365.2
FR-A840-06830-1-U6 (*1)683610547481550500450400365.2
FR-A842-07700-1-U6 +FR-CC2-H315K-60 (*2)--610547--500450P+R820.6
FR-A842-08660-1-U6 + FR-CC2-H315K-60 (*2)---610---500820.6
FR-A842-07700-1-U6 + FR-CC2-H355K-60 (*2)-683---550--827.2
FR-A842-08660-1-U6 + FR-CC2-H355K-60 (*2)--683---550-827.2
FR-A842-09620-1-U6 + FR-CC2-H355K-60 (*2)---683---550Q+R1003.2
FR-A842-07700-1-U6 + FR-CC2-H400K-60 (*2)770---650---P+S979
FR-A842-08660-1-U6 + FR-CC2-H400K-60 (*2)-770---650--979
FR-A842-09620-1-U6 + FR-CC2-H400K-60 (*2)--770---650-Q+S1155
FR-A842-10940-1-U6 + FR-CC2-H400K-60 (*2)---770---6501155
FR-A842-08660-1-U6 + FR-CC2-H450K-60 (*2)866---700---P+S986
FR-A842-09620-1-U6 + FR-CC2-H450K-60 (*2)-866---700--Q+S1162
FR-A842-10940-1-U6 + FR-CC2-H450K-60 (*2)--866---700-1162
FR-A842-12120-1-U6 + FR-CC2-H450K-60 (*2)---866---7001162
FR-A842-09620-1-U6 + FR-CC2-H500K-60 (*2)962---800---1168
FR-A842-10940-1-U6 + FR-CC2-H500K-60 (*2)-962---800--1168
FR-A842-12120-1-U6 + FR-CC2-H500K-60 (*2)--962---800-1168
FR-A842-10940-1-U6 + FR-CC2-H560K-60 (*2)1094---900---1179
FR-A842-12120-1-U6 +FR-CC2-H560K-60 (*2)-1094---900--1179
FR-A842-12120-1-U6 + FR-CC2-H630K-60 (*2)1212---1000---1181
 
Notes:
1. These drives must be used with DC Link Chokes (sold separately).
2. Drives are "sectional" design, used together with FR-CC2 rectifier stage.
3. Consult VFD Marketing for availability.
4. For FR-A842 and FR-CC2 combinations, the weights are COMBINED. Drives in shaded area MUST be used together with FR-HEL DC Link Choke (sold separately).
 
 

 

FR-HEL DC Link Chokes (sold separately)

 

 

Model NumberSLDLDNDHD
FR-A840-01800-1-60FR-HEL-H110KFR-HEL-H75K--
FR-A840-02160-1-U6FR-HEL-H110KFR-HEL-H90KFR-HEL-H75KFR-HEL-H75K
FR-A840-02600-1-U6FR-HEL-H132KFR-HEL-H110KFR-HEL-H90KFR-HEL-H90K
FR-A840-03250-1-U6FR-HEL-H160KFR-HEL-H132KFR-HEL-H110KFR-HEL-H110K
FR-A840-03610-1-U6FR-HEL-H185KFR-HEL-H160KFR-HEL-H132KFR-HEL-H132K
FR-A840-04320-1-U6FR-HEL-H220KFR-HEL-H185KFR-HEL-H160KFR-HEL-H160K
FR-A840-04810-1-U6FR-HEL-H250KFR-HEL-H220KFR-HEL-H185KFR-HEL-H185K
FR-A840-05470-1-U6FR-HEL-H280KFR-HEL-H250KFR-HEL-H220KFR-HEL-H220K
FR-A840-06100-1-U6FR-HEL-H315KFR-HEL-H280KFR-HEL-H250KFR-HEL-H250K
FR-A840-06830-1-U6FR-HEL-H355KFR-HEL-H315KFR-HEL-H280KFR-HEL-H280K

 

 

 

FR-A800 Ratings 600V Class

 

 

Model Number (*4)AMPS for DutyHorsepower for Duty (NEC)Frame SizeWeight (lbs)
SLDLDNDHDSLDLDNDHD
FR-A860-00027-1-N62.72.51.7121.510.5C11.7
FR-A860-00061-1-N66.15.642.75332C12.8
FR-A860-00090-1-N698.26.147.5553C12.8
FR-A860-00170-1-N617161291510107.5D15.4
FR-A860-00320-1-N63227221630252010E19.8
FR-A860-00450-1-N64541332440403020F37.4
FR-A860-00680-1-606862554160605040H79.2
FR-A860-01080-1-60 (*1)1089984631001007560H90.2
FR-A860-01440-1-60 (*1)1441311048415012510075J114
FR-A860-01670-1-60 (*1)167152131104150150125100J114
FR-A860-02430-1-60 (*1)243221152131250200150125J121
FR-A860-02890-1-60 (*1)289255221152300250200150M246
FR-A860-03360-1-60 (*1)336304255202350300250200M253
FR-A860-04420-1-60 (*1)442402304255450400300250N337
FR-A862-05450-1-60 +
FR-CC2-C355K-60 (*2)
545496402304550500400300P+R810
FR-A862-06470-1-60 +
FR-CC2-C400K-60 (*2)
647589496402650600500400Q+S920
FR-A862-08500-1-60 +
FR-CC2-C560K-60 (*2)
850773663589850750650600Q+S1126
 
Notes:
1. These drives MUST be used with a DC Link Choke (sold separately).
2. FR-A862 Drives are inverter stage only; use together with FR-CC2-C rectifier stage. Maximum Input and Output Current of FR-CC2 modules is the value shown. COMBINED weight shown.
3. Remove the standard brake resistor (if fitted) for UL type 1. Rating is otherwise NEMA 1.
4. The FR-A860 does not include a built in parameter unit. The FR-DU08 or FR-LU08 is sold separately.

 

 

 

FR-HEL DC Link Chokes (sold separately)

 

 

Model NumberSLDLDNDHD
FR-A860-01080-1-60FR-HEL-C75KFR-HEL-C75K--
FR-A860-01440-1-60FR-HEL-C90KFR-HEL-C90KFR-HEL-C75K-
FR-A860-01670-1-60FR-HEL-C110KFR-HEL-C110KFR-HEL-C90KFR-HEL-C75K
FR-A860-02430-1-60FR-HEL-C132KFR-HEL-C132KFR-HEL-C110KFR-HEL-C90K
FR-A860-02890-1-60FR-HEL-C185KFR-HEL-C185KFR-HEL-C132KFR-HEL-C110K
FR-A860-03360-1-60FR-HEL-C220KFR-HEL-C220KFR-HEL-C185KFR-HEL-C185K
FR-A860-04420-1-60FR-HEL-C280KFR-HEL-C280KFR-HEL-C220KFR-HEL-C185K

 

 

 

Dimensions of REQUIRED DC Link Chokes (sold separately)

 

 

Model NumberHeight - inches (mm)Width - inches (mm)Depth - inches (mm)Weight (lbs)
FR-HEL-75K13.39 (340)5.91 (150)7.87 (200)37
FR-HEL-90K13.39 (340)5.91 (150)7.87 (200)42
FR-HEL-110K15.75 (400)6.89 (175)7.87 (200)44
FR-HEL-H75K12.60 (320)5.51 (140)7.28 (185)35
FR-HEL-H90K13.39 (340)5.91 (150)7.48 (190)44
FR-HEL-H110K13.39 (340)5.91 (150)7.68 (195)48
FR-HEL-H132K15.94 (405)6.89 (175)7.87 (200)57
FR-HEL-H160K15.94 (405)6.89 (175)8.07 (205)62
FR-HEL-H185K15.94 (405)6.89 (175)9.45 (240)64
FR-HEL-H220K15.94 (405)6.89 (175)9.45 (240)66
FR-HEL-H250K17.32 (440)7.48 (190)9.84 (250)77
FR-HEL-H280K17.32 (440)7.48 (190)10.04 (255)84
FR-HEL-H315K19.5 (495)8.3 (210)9.8 (250)92
FR-HEL-H355K19.5 (495)8.3 (210)9.8 (250)101
FR-HEL-C75K12.6 (320)5.5 (140)7.3 (185)35
FR-HEL-C90K13.3 (340)5.9 (150)9.4 (240)44
FR-HEL-C110K13.3 (340)5.9 (150)9.4 (240)51
FR-HEL-C132K15.9 (405)6.9 (175)7.7 (195)53
FR-HEL-C185K15.9 (405)6.9 (175)9.4 (240)70
FR-HEL-C220K15.9 (405)6.9 (175)9.4 (240)73
FR-HEL-C280K17.3 (440)7.5 (190)9.8 (250)88

 

 

 

Liability:

 

 

WTL is not liable for any personal injury or property damage resulting from the use of this equipment. It is
 
buyer's responsibility as to the safe handling & operation of this equipment and to verify equipment is
 
compliance to their machinery.
 
 

Contact person:Suki

Email:wtl2502keji@163.com

Skype:wtl2502

Tel:+86-13268302140

Hot Products

Emerson KJ3221X1-BA1 AO, 8-Channel, 4-20 mA, HART Series 2 Redundant Card Redundant Power Supply ...
ABB Redundant Power Supply Module IMASI23 infi 90 AC System Power Supply Module Control Board ...
Q00UJCPU MITSUBISHI Universal Redundant Power Supply Module 100 to 240 V AC input / 5 V DC/3 A ...
Redundant Power Supply Module Mitsubishi Universal model CPU Q01UCPU 15 k steps Model: Q01UCPU No.of ...
Q02UCPU 2048 points. Redundant Power Supply Module Mitsubishi Universal model CPU Model: Q02UCPU No...
Q03UDCPU Universal model Redundant Power Supply Module Mitsubishi 30 k steps Model: Q03UDCPU No.of I...