UL1007 Single Conductor with Extruded Insulation, 80 C, 300 V,
VW-1,60 deg C or 80 deg C Oil
Construction
Conductor : Solid or Stranded
Insulation: PVC
Standards
International: UL758 , UL1581, UL2556
RoHS,REACH Compliant,
Technical data
Rated voltage:300V
Rated Temperature: 80 OC
Flame: VW-1, FT1, FT2
Oil resistance: 60 deg C or 80 deg C Oil
Voltage withstand test:AC 2.0kV/1min
Printing :E258652 AWM STYLE 1007 AWGXX 80℃ 300V VW-1 ---c AWM I A/B 80℃
300V FT1 -LF-HWATEK
Note: Where "XX" means AWG No.
Specifications
Part NO. | Size (AWG) | Tinned copper stranded | Insulation(PVC 80℃) | Construction | Dia. (mm) | Resistance (Ω/km) | Avg. thick. (mm) | Min. thick. (mm) | Outer Dia. (mm) | HT1201509 | 30 | 7/0.10 | 0.30 | 381 | 0.38 | 0.33 | 1.10±0.05 | HT1201510 | 28 | 7/0.127 | 0.38 | 239 | 0.38 | 0.33 | 1.20±0.05 | HT1201511 | 26 | 7/0.16 | 0.48 | 150 | 0.38 | 0.33 | 1.30±0.05 | HT1201512 | 24 | 11/0.16 | 0.61 | 94.2 | 0.38 | 0.33 | 1.40±0.10 | HT1201513 | 22 | 17/0.16 | 0.76 | 59.4 | 0.38 | 0.33 | 1.60±0.10 | HT1201514 | 20 | 26/0.16 | 0.94 | 36.7 | 0.38 | 0.33 | 1.80±0.10 | HT1201515 | 18 | 41/0.16 | 1.18 | 23.2 | 0.38 | 0.33 | 2.10±0.10 | HT1201516 | 16 | 26/0.254 | 1.5 | 14.6 | 0.38 | 0.33 | 2.30±0.10 |
|
|
Certificates
UL, CUL, CE
Packing and Shipping
- The cargo could be packaged as Hwatek’s standard requirement if
client no special request, such as carton, wooden pallet or wooden
case;
- If client put forward special packing requirements, Hwatek will
specialize in custom materials and charge some fees;
- Hwatek’ll pack the cargo according to the transportation
requirements strictly, including size, weight and safety;
- The cargo, manufacturer, packing details will be labeled on the
outer packing;
- About transportation agent, Hwatek will give priority to customers'
advice. If not, we can come up with some proposals and choose good
and affordable agents for clients reference;
- Shipping term, It depends on the value of the goods and the will of
the customer.