Home Companies Yueqing Richuang Automation Equipment Co.,Ltd

CPU 412 6ES7412-2EK07-0AB0 Industrial Automation Products Central Processing Unit

Yueqing Richuang Automation Equipment Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Liushi Town,Yueqing City,Zhejiang Province,China

Contact name:

Inquir Now

Yueqing Richuang Automation Equipment Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CPU 412 6ES7412-2EK07-0AB0 Industrial Automation Products Central Processing Unit

Country/Region china
City & Province zhejiang
Categories Solar Chargers
InquireNow

Product Details

    Siemens CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit SIMATIC Industrial Automation Products

 

Application

The CPU 412-1 is the low-cost entry into the medium performance range. It can be used in smaller systems with limited I/O configuration. The combined MPI/DP interface also enables operation of a PROFIBUS DP line.

The CPU 412-2 is the CPU for applications in the mid-performance range with 2 PROFIBUS DP master systems.

For networking within a PROFINET network, the CPU 412-2 PN is available.

 
Function
  • Block protection:
    A password concept also protects the user program from unauthorized access
  • Integrated HMI services:
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
  • Integrated communication functions:
    • PG/OP communication
    • Global data communication
    • S7 standard communication
    • S7 communication
Programmable properties

The STEP 7 tool "Hardware configuration" can be used to parameterize the properties and response of the S7-400 including the CPUs, e.g.

  • Multipoint interface MPI:
    • Definition of node addresses
    • Startup/cycle behavior
    • Stipulation of the maximum cycle time and communication load
  • Address allocation:
    Addressing of I/O modules
  • Retentive area:
    Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
  • Size of the process image, local data
  • Length of the diagnostics buffer
  • Protection level:
    Definition of access authorizations to program and data
  • System diagnostics:
    Definition of the handling and scope of diagnostics messages
  • Timed interrupts:
    Setting of periodicity
Display and information functions
  • Status and fault indicators:
    LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
  • Test functions:
    The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
  • Information functions:
    The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

Technical specifications

Article number

6ES7412-1XJ07-0AB0

6ES7412-2XK07-0AB0

6ES7412-2EK07-0AB0

 

CPU412-1, MPI/DP, 512 KB

CPU412-2, MPI/DP, 1 MB

CPU412-2 PN, 1 MB, 2 SCHNITTSTELLEN

General information   
Product type designationCPU 412-1CPU 412-2CPU 412-2 PN
HW functional status010101
Firmware versionV7.0V7.0V7.0
Engineering with   
  • ● Programming package

STEP 7 V5.4 or higher with HSP 261STEP 7 V5.4 or higher with HSP 261STEP 7 V5.5 or higher with HSP 262
CiR – Configuration in RUN   
CiR synchronization time, basic load100 ms100 ms100 ms
CiR synchronization time, time per I/O byte30 µs30 µs30 µs
Supply voltage   
Rated value (DC)   
  • ● 24 V DC

No; Power supply via system power supplyNo; Power supply via system power supplyNo; Power supply via system power supply
Input current   
from backplane bus 5 V DC, typ.0.7 A0.9 A1.1 A
from backplane bus 5 V DC, max.0.8 A1.1 A1.4 A
from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface300 mA; 150 mA per DP interface150 mA; 150 mA per DP interface
from interface 5 V DC, max.90 mA; At the DP interface90 mA; At each DP interface90 mA; At the DP interface
Power loss   
Power loss, typ.3.5 W4.5 W5.5 W
Power loss, max.4 W5.5 W7 W
Memory   
Type of memoryRAMRAMRAM
Work memory   
  • ● integrated

512 kbyte1 Mbyte1 Mbyte
  • ● integrated (for program)

256 kbyte512 kbyte512 kbyte
  • ● integrated (for data)

256 kbyte512 kbyte512 kbyte
  • ● expandable

NoNoNo
Load memory   
  • ● expandable FEPROM

Yes; with Memory Card (FLASH)Yes; with Memory Card (FLASH)Yes; with Memory Card (FLASH)
  • ● expandable FEPROM, max.

64 Mbyte64 Mbyte64 Mbyte
  • ● integrated RAM, max.

512 kbyte512 kbyte512 kbyte
  • ● expandable RAM

Yes; with Memory Card (RAM)Yes; with Memory Card (RAM)Yes; with Memory Card (RAM)
  • ● expandable RAM, max.

64 Mbyte64 Mbyte64 Mbyte
Backup   
  • ● present

YesYesYes
  • ● with battery

Yes; all dataYes; all dataYes; all data
  • ● without battery

NoNoNo
Battery   
Backup battery   
  • ● Backup current, typ.

180 µA; up to 40 °C180 µA; up to 40 °C180 µA; up to 40 °C
  • ● Backup current, max.

850 µA850 µA850 µA
  • ● Backup time, max.

Dealt with in the module data manual with the secondary conditions and the factors of influenceDealt with in the module data manual with the secondary conditions and the factors of influenceDealt with in the module data manual with the secondary conditions and the factors of influence
  • ● Feeding of external backup voltage to CPU

5 V DC to 15 V DC5 V DC to 15 V DC5 V DC to 15 V DC
CPU processing times   
for bit operations, typ.31.25 ns31.25 ns31.25 ns
for word operations, typ.31.25 ns31.25 ns31.25 ns
for fixed point arithmetic, typ.31.25 ns31.25 ns31.25 ns
for floating point arithmetic, typ.62.5 ns62.5 ns62.5 ns
CPU-blocks   
DB   
  • ● Number, max.

3 000; Number range: 1 to 160003 000; Number range: 1 to 160003 000; Number range: 1 to 16000
  • ● Size, max.

64 kbyte64 kbyte64 kbyte
FB   
  • ● Number, max.

1 500; Number range: 0 to 79991 500; Number range: 0 to 79991 500; Number range: 0 to 7999
  • ● Size, max.

64 kbyte64 kbyte64 kbyte
FC   
  • ● Number, max.

1 500; Number range: 0 to 79991 500; Number range: 0 to 79991 500; Number range: 0 to 7999
  • ● Size, max.

64 kbyte64 kbyte64 kbyte
OB   
  • ● Number, max.

see instruction listsee instruction listsee instruction list
  • ● Size, max.

64 kbyte64 kbyte64 kbyte
  • ● Number of free cycle OBs

1; OB 11; OB 11; OB 1
  • ● Number of time alarm OBs

2; OB 10, 112; OB 10, 112; OB 10, 11
  • ● Number of delay alarm OBs

2; OB 20, 212; OB 20, 212; OB 20, 21
  • ● Number of cyclic interrupt OBs

2; OB 32, 35 (shortest cycle that can be set = 500 µs)2; OB 32, 35 (shortest cycle that can be set = 500 µs)2; OB 32, 35 (shortest cycle that can be set = 500 µs)
  • ● Number of process alarm OBs

2; OB 40, 412; OB 40, 412; OB 40, 41
  • ● Number of DPV1 alarm OBs

3; OB 55-573; OB 55-573; OB 55-57
  • ● Number of isochronous mode OBs

2; OB 61-622; OB 61-622; OB 61-62
  • ● Number of multicomputing OBs

1; OB 601; OB 601; OB 60
  • ● Number of background OBs

1; OB 901; OB 901; OB 90
  • ● Number of startup OBs

3; OB 100-1023; OB 100-1023; OB 100-102
  • ● Number of asynchronous error OBs

9; OB 80-889; OB 80-889; OB 80-88
  • ● Number of synchronous error OBs

2; OB 121, 1222; OB 121, 1222; OB 121, 122
Nesting depth   
  • ● per priority class

242424
  • ● additional within an error OB

111
Counters, timers and their retentivity   
S7 counter   
  • ● Number

2 0482 0482 048
Retentivity   
  • — adjustable

YesYesYes
  • — lower limit

000
  • — upper limit

2 0472 0472 047
  • — preset

Z 0 to Z 7Z 0 to Z 7Z 0 to Z 7
Counting range   
  • — lower limit

000
  • — upper limit

999999999
IEC counter   
  • ● Number

Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)
S7 times   
  • ● Number

2 0482 0482 048
Retentivity   
  • — adjustable

YesYesYes
  • — lower limit

000
  • — upper limit

2 0472 0472 047
  • — preset

No times retentiveNo times retentiveNo times retentive
Time range   
  • — lower limit

10 ms10 ms10 ms
  • — upper limit

9 990 s9 990 s9 990 s
IEC timer   
  • ● present

YesYesYes
  • ● Type

SFBSFBSFB
  • ● Number

Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)
Data areas and their retentivity   
retentive data area in totalTotal working and load memory (with backup battery)Total working and load memory (with backup battery)Total working and load memory (with backup battery)

 

 

Main Models of Siemens CPU SIMATIC Central Processing Unit:

CPU
6ES7414-3XM05-0AB0
6ES7412-1XF03-0AB0
6ES7412-1XJ05-0AB0
6ES7412-2XG00-0AB0
6ES7412-1XJ05-0AB0
6ES7412-2XJ05-0AB0
6ES7414-2XK05-0AB0
6ES7416-2XN05-0AB0
6ES7412-2XJ05-0AB0
6ES7412-3HJ14-0AB0
6ES7414-2XG03-0AB0
6ES7414-2XG04-0AB0
6ES7414-2XG03-0AB0
6ES7414-2XK05-0AB0
6ES7414-3XJ00-0AB0
6ES7414-3XJ04-0AB0
6ES7414-3XM05-0AB0
6ES7414-4HJ00-0AB0
6ES7414-4HJ04-0AB0
6ES7414-4HM14-0AB0
6ES7416-2XN05-0AB0
6ES7416-2XK02-0AB0
6ES7416-3XL00-0AB0
6ES7416-3XL04-0AB0
6ES7416-3XR05-0AB0
6ES7416-3FR05-0AB0
6ES7417-4XL00-0AB0
6ES7417-4XT05-0AB0

 

400H CPU
6ES7414-4HJ04-0AB0
6ES7414-4HM14-0AB0
6ES7417-4HL04-0AB0
6ES7417-4HT14-0AB0

 

Hot Products

3RT1054-6AP36 115 A 55 kW MOTOR CONTACTOR 400VAC/ DC 220-240V 2NO 2NC CONTACTOR Power contactor, AC...
3RT1055-6AF36 150A 3 POLE POWER CONTACTOR 75kW DC 110V MOTOR CONTACTOR Power contactor, AC-3 150 A, ...
3RT1056-6AP36 3POLE 400VAC CONTROL CONTACTOR 90kW DC OPERATION 220-240V CONTACTOR Power contactor, ...
3RT1064-6AP36 225A AC ELECTRICAL CONTACTOR 110kW MOTOR CONTACTOR 220V DC CONTACTOR Power contactor, ...
Siemens SIRIUS 3RT1065-6AP36 up to 250 kW DC CONTACTOR 265A 132 kW Power CONTACTOR Power contactor, ...
Factory OEM LC1 Magnetic Three Phases AC Contactor High Quality 3 Poles LC1-D Electrical Contactor ...