IEC60669 Clause 18.3 Halogen Filament Lamp Load Bank For switches
Of Overload Test
Standard
UL1054,UL943, IEC 60669-1 :2017 Clause 18.3
Application
it is suitable for the overload test with filament lamps for
switches, supply 1.2 times rated current of test switches.
Technical parameters:
1. Input power: AC 220V, 20A, 50/60Hz (It depends on customer's national requirements)
2. the output voltage: AC 0 ~ 250V continuously adjustable,4
display instrument display, accuracy 0.5%
3. Test current: This is achieved by connecting the number of
halogen lamps rated at 200W in parallel. (Number of halogen lamps:
30, switch rated current 16A); Output current:0~24 A(can be customed)
4. The system can automatically detect whether the halogen lamp is
damaged. Once it is damaged, it can automatically access the spare
lamp. When the number of normal lamps is not enough, the system
will automatically stop the test and give an audible and visual
alarm;
5. Touch screen display: test voltage, test current, number of
tests, bulb failure location, warning light information.
6.Counter: 1 ~ 999999 times can be preset
7.the number of output channels: 1
8.overtime protection: with the test current continuous power
circuit protection function for 5 seconds.
9. surge current coefficient: Meet the requirements of UL1054
5.7.9, about 10-18 times.
10. The control plane size: about 1200 × 800 × 1700 (mm)
Standard | UL1054,UL943, IEC 60669-1 :2017 Clause 18.3 |
Output voltage | 0~250V |
Output current | 0~24A |
Accuracy | 0.50% |
Counter | 1 ~ 999999 times can be preset |
The control plane size | 1200 × 800 × 1700 (mm) |
Number of halogen lamps | 30 |
switch rated current | 16A |
Control | PLC, Programmable |
Operation interface | 7" Touch screen |
Picture for reference: