Meeting MD15D Air To Water Heat Pump Water Heaters For Small Space Heating

 

Technology Specification

 

 

AIR SOURCE HEAT PUMP FEATURE

 

 

»Auxiliary electronic heater or solar coiler is on your option

 

» Fashionable design, compact structure, saving the place.

 

»Quiet, lower the noise when the unit is running

 

»Advance control panel. Timer function , automatic defrosting function, optional electrical heating, error messages showed for warning.

 

»It can be work in -15°C low ambient temperature.

 

Hot water output temperature up to 60°C, for domestic hot water or heating.

 

auto-defrosting function included. And cooling is optional

 

 

A. Payment service

1. T/T

 

 

B. Technical service

1. We calculate the capacity and recommend the best models.

2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.

3. We supply the spare parts and technical support in and after the warranty time.

4. We supply the training course to your workers at our factory if you need.

5. We can offer site training to your workers in your place which is negotiable.

 

 

FAQ

 

Why us?

1. Timely Delivery, considerate sales after service.

2. 1 Year heat pump warranty, unlimited period for online support.

    --You can also pay for extended warranty or we can renegotiate the longer warranty period.

3. Top Craftmanship, All products 100% tested.

4. Preferential freight by Famous shipping company.

5. New Design,Very popular style products recommendation for your local market.

 

 

Packaging & Shipment

 

1> Delivery Time : Usually 15 working days after payment

 

2> Packaging Details :Standard export packing - plywood case with dusty-proof film inside,OEM is acceptable for Factory price.

 

3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

 

4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order.

 

5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

 

 

 

MODELUnitMD10D
Rated heating capacityKW3.5
Rated Cooling capacity 1.8
Hot water supplyL/h75
Average heating input powerKW0.75
Rated heating input currentA6
Rate outlet water temp55
COP 3.65
PowerV/Hz220V/50
NoiseDb(a)48
DimensionW*D*Hmm1140×360×540
Packing sizeW*D*Hmm1200*400*710
Unit weightKG75
Refrigerant R417A
Working air temp range(-20℃)—45℃
compressorType Panasonic
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H1000L/h
Water pressure downKpa30
Pipe sizeDN20
Max flat square meterM229
MODELUnitMD15D
Rated heating capacityKW5
Rated Cooling capacity 3
Hot water supplyL/h100
Average heating input powerKW1.25
Rated heating input currentA6
Rate outlet water temp55
COP 3.65
PowerV/Hz220V/50
NoiseDb(a)48
DimensionW*D*Hmm1140×360×540
Packing sizeW*D*Hmm1200*400*710
Unit weightKG75
Refrigerant R417A
Working air temp range(-20℃)—45℃
compressorType Panasonic
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H1600L/h
Water pressure downKpa30
Pipe sizeDN20
Max flat square meterM240
MODELUnitMD20D
Rated heating capacityKW7
Rated Cooling capacity 5
Hot water supplyL/h150
Average heating input powerKW1.84
Rated heating input currentA9
Max outlet water temp60
COP 3.8
PowerV/Hz220V/50
NoiseDb(a)50
DimensionW*D*Hmm1140×360×540
Packing sizeW*D*Hmm1200*400*710
Unit weightKG75
Refrigerant R417A//R410
Working air temp range(-20℃)—45℃
compressorType Panasonic
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H2000L/h
Water pressure downKpa30
Pipe sizeDN20
Max flat square meterM255
MODELUnitMD30D
Rated heating capacityKW12
Rated Cooling capacity 7
Hot water supplyL/h260
Average heating input powerKW3
Rated heating input currentA13/6
Max outlet water temp60
COP 4
PowerV/Hz220V/380/50
NoiseDb(a)54
DimensionW*D*Hmm1120*490*710mm
Packing sizeW*D*Hmm1190*520*865mm
Unit weightKG108
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H3000L/h
Water pressure downKpa40
Pipe sizeDN25
Max flat square meterM2100
MODELUnitMD40D
Rated heating capacityKW16
Rated Cooling capacity 10
Hot water supplyL/h360
Average heating input powerKW4
Rated heating input currentA9
Max outlet water temp60
COP 4.2
PowerV/Hz380V/50
NoiseDb(a)55
DimensionW*D*Hmm1120*490*1270
Packing sizeW*D*Hmm1200*520*1425
Unit weightKG160
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H4000L/h
Water pressure downKpa45
Pipe sizeDN25
Max flat square meterM2125
MODELUnitMD50D
Rated heating capacityKW18
Rated Cooling capacity 12
Hot water supplyL/h400
Average heating input powerKW4.4
Rated heating input currentA9
Max outlet water tempC60
COP 4.2
PowerV/Hz380V/50
NoiseDb(a)55
DimensionW*D*Hmm1120*490*1270
Packing sizeW*D*Hmm1200*520*1425
Unit weightKG160
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H5000L/h
Water pressure downKpa45
Pipe sizeDN25
Max flat square meterM2150
MODELUnitMD60D
Rated heating capacityKW21
Rated Cooling capacity 15
Hot water supplyL/h520
Average heating input powerKW5.68
Rated heating input currentA12
Max outlet water temp60
COP 4.2
PowerV/Hz380/50
NoiseDb(a)60
DimensionW*D*Hmm1120*490*1270
Packing sizeW*D*Hmm1200*520*1425
Unit weightKG210
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H6000
Water pressure downKpa48
Pipe sizeDN25
Max flat square meterM2175
MODELUnitMD100D
Rated heating capacityKW36
Rated Cooling capacity 24
Hot water supplyL/h800
Average heating input powerKW9.2
Rated heating input currentA18
Max outlet water temp60
COP 4.2
PowerV/Hz380V/50
NoiseDb(a)60
DimensionW*D*Hmm1450×760×1060
Packing sizeW*D*Hmm1520*800*1230
Unit weightKG289
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H10000L/h
Water pressure downKpa54
Pipe sizeDN32
Max flat square meterM2300
MODELUnitMD150D
Rated heating capacityKW42
Rated Cooling capacity 29
Hot water supplyL/h1200
Average heating input powerKW11
Rated heating input currentA18
Max outlet water temp60
COP 4.2
PowerV/Hz380V/50
NoiseDb(a)60
DimensionW*D*Hmm1450×760×1060
Packing sizeW*D*Hmm1520*800*1230
Unit weightKG320
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H15000L/h
Water pressure downKpa54
Pipe sizeDN32
Max flat square meterM2350
MODELUnitMD200D
Rated heating capacityKW72
Rated Cooling capacity 48
Hot water supplyL/h1590
Average heating input powerKW18.2
Rated heating input currentA35
Max outlet water temp60
COP 4.5
PowerV/Hz380V/50
NoiseDb(a)65
DimensionW*D*Hmm2040×1100×2000
Packing sizeW*D*Hmm2080×1150×2130
Unit weightKG650
Refrigerant R417A/R407C/R404A
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H20000L/h
Water pressure downKpa60
Pipe sizeDN50
Max flat square meterM2600
MODELUnitMD300D
Rated heating capacityKW88
Rated Cooling capacity 65
Hot water supplyL/h24000
Average heating input powerKW25
Rated heating input currentA45
Max outlet water temp60
COP 4.5
PowerV/Hz380V/50
NoiseDb(a)68
DimensionW*D*Hmm2040×1100×2000
Packing sizeW*D*Hmm2080×1150×2130
Unit weightKG650
Refrigerant R417A/R407C
Working air temp range (-20℃)—45℃
compressorType Copeland
Air source heat exchangerType Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchangeType Coil heat exchanger
Water flowL/H30000L/h
Water pressure downKpa60
Pipe sizeDN50
Max flat square meterM2730

 

 

Hot Products

Meeting 7KW MD20D CE Approved Air Source Heat Pump Water Heater Able To Combine With Solar Heater ...
Meeting 12KW MD30D CE certified low temperature air source heat pump water heater able to combine ...
Meeting 4.8KW CE certified air source heat pump water heater, a hot water system that can be ...
Meeting16KW MD40D CE Certified Air Source Heat Pump Water Heater Can Be Combined With Solar Water ...
Meeting MD30D 12KW Safe And Reliable Water Heater Air-To-Water Energy-Saving Air Source Heat Pump ...
Meeting MD50D 18.6KW Heat Pump Water Heater Air-To-Water Energy Saving Air Source Heat Pump Water ...