Guangzhou Jin Lun Electric Equipment Co.,Ltd |
|
21KW Heating House and domestic water hot Home Heat Pump display LCD figer Touch
Technology Specification
Use
Business Organizations
Supermarket, shopping malls, shops, department store, star-rated
hotels, restaurants, school, office;
Public Places
subway, airports, stations, bookstores, exhibition halls, stadiums, museums, commercial buildings, hospital;
Entertainments Movie theaters, clubs, bars, cafes, Internet bars, beauty shops
Control panel
Cooperate paratner
Internal porduct accessories
1 compressor :
The world-famous Copeland Flexible Scroll Compressor has functions such as low wear resistance,
long service life, over-current protection, phase loss protection, over-the-counter protection, strong liquid-impact resistance, and high and low voltage protection.
Copeland compressor built-in pressure relief valve in the body can automatically relieve pressure when the high pressure is too high
|
2 Electronic expansion valve:
The introduction of the latest Japanese technology in conjunction with the company's control system has
led to the development of a unique electronic expansion valve control method and the use of digital
technology control to control the working fluid to achieve the best flow velocity effect, thereby increasing
the COP value.
|
3 Condenstion heat exchanger:
successfully created a "spring" spiral tube new structure condenser.
Better heat transfer, faster heat transfer, and higher efficiency, minimize fouling, extend heat pump life and reduce maintenance
|
4 Electronic control system :
With powerful engineering supporting control functions , it can control circulating water pump, make-up water , return water, water supply , electric heating , PID automatic defrosting, etc., making the control easier.
According to the needs of different projects, it can set various parameters by itself and realize various water supply schemes .
The entire system can be automated without special care. |
5 Evaporation heat exchanger:
The use of hydrophilic membrane aluminum foil, even after long-term use
|
After selling
1. We promise to offer free consulting call in 7~24 hours mode to
solve the problems found in practice.
2. Products guarantee is 18~24 months from ex-factory date. Within
18months,if any components of your products damaged because of
quality, we supply new replacement for free.
3. After the expiration of the quality assurance, we will continue
to provide lifelong maintenance services, with just charging some
cost price.
FAQ
Why us?
1. Timely Delivery, considerate sales after service
2. Many Years quality warranty,OEM service.
3. Top Craftmanship, All products 100% tested
4. Preferential freight by Famous shipping company
5. New Design,Very popular style products recommendation for your local market
Air source heat pump parameters tables
MODEL | Unit | MD10D | |
Rated heating capacity | KW | 3.5 | |
Rated Cooling capacity | 1.8 | ||
Hot water supply | L/h | 75 | |
Average heating input power | KW | 0.75 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 29 | |
MODEL | Unit | MD15D | |
Rated heating capacity | KW | 5 | |
Rated Cooling capacity | 3 | ||
Hot water supply | L/h | 100 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1600L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 40 | |
MODEL | Unit | MD20D | |
Rated heating capacity | KW | 7 | |
Rated Cooling capacity | 5 | ||
Hot water supply | L/h | 150 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A//R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 55 | |
MODEL | Unit | MD30D | |
Rated heating capacity | KW | 12 | |
Rated Cooling capacity | 7 | ||
Hot water supply | L/h | 260 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 60 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 54 | |
Dimension | W*D*H | mm | 1120*490*710mm |
Packing size | W*D*H | mm | 1190*520*865mm |
Unit weight | KG | 108 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 3000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 100 | |
MODEL | Unit | MD40D | |
Rated heating capacity | KW | 16 | |
Rated Cooling capacity | 10 | ||
Hot water supply | L/h | 360 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 4000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 125 | |
MODEL | Unit | MD50D | |
Rated heating capacity | KW | 18 | |
Rated Cooling capacity | 12 | ||
Hot water supply | L/h | 400 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 5000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 150 | |
MODEL | Unit | MD60D | |
Rated heating capacity | KW | 21 | |
Rated Cooling capacity | 15 | ||
Hot water supply | L/h | 520 | |
Average heating input power | KW | 5.68 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 6000 | |
Water pressure down | Kpa | 48 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 175 | |
MODEL | Unit | MD100D | |
Rated heating capacity | KW | 36 | |
Rated Cooling capacity | 24 | ||
Hot water supply | L/h | 800 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 10000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 300 | |
MODEL | Unit | MD150D | |
Rated heating capacity | KW | 42 | |
Rated Cooling capacity | 29 | ||
Hot water supply | L/h | 1200 | |
Average heating input power | KW | 11 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 350 | |
MODEL | Unit | MD200D | |
Rated heating capacity | KW | 72 | |
Rated Cooling capacity | 48 | ||
Hot water supply | L/h | 1590 | |
Average heating input power | KW | 18.2 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 20000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 600 | |
MODEL | Unit | MD300D | |
Rated heating capacity | KW | 88 | |
Rated Cooling capacity | 65 | ||
Hot water supply | L/h | 24000 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 30000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 730 |