Guangzhou Jin Lun Electric Equipment Co.,Ltd |
|
100kW Commercial Air to water Juteng Swimming pool Air source Heat Pump High COP Top type pool equipment
Technology Specification
Advantage
*Constant heating and cooling function, applicable to swimming
pool, Spa or fish cultivation.
*Advanced corrosion resistance Titanium heat exchanger, virtually
impervious to water chemistry damage.
*World famous Japanese brand compressor.
*Digital LCD display wire control panel, controls water temperature
to within 1-5°C difference from set point.
*On-off timing function, no human attendance is required for
operation once started.
*Insufficient water flow protection & high/low pressure
protection.
*Auto defrosting with 4-way valve, ensure reliably running at low
ambient temperature.
*Warms your pool or SPA with the reliability and efficiency can also cool your pool and SPA
during hot summer season.
1) Swimming pool heat pump, Up to 80% energy saving, compared with conventional water heaters such as gas/oil boilers and electricity resistance water heaters
2) LCD display control panel
3) Automatic unit on/off timer clock. No human attendance is
required once unit is started
4)Insufficient water flow and high/low pressure protection
5) Users can regulate the outlet water temperature in accordance
with different project requirements.
6) Strong defrosting function and able to work reliably at cold ambient air temperature
7) Corrosion resistant titanium heat exchanger
8) Cold water function optional and suitable for hot areas where
pool water need to cooled in summer
Swimming pool heat pump parameters tables
MODEL | Unit | MDY10D | |
Rated heating capacity | KW | 3.5 | |
Average heating input power | KW | 0.8 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×538 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1200L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY15D | |
Rated heating capacity | KW | 5.5 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×539 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1800L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY20D | |
Rated heating capacity | KW | 9 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 7 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 75 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 3500L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY30D | |
Rated heating capacity | KW | 14 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 35 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*790mm |
Packing size | W*D*H | mm | 1200*520*870mm |
Unit weight | KG | 110 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 5500L/h | |
Water pressure down | Kpa | 40 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY40D | |
Rated heating capacity | KW | 16 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 18/9 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1440 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 6500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY50D | |
Rated heating capacity | KW | 19 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 7500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY60D | |
Rated heating capacity | KW | 26 | |
Average heating input power | KW | 6 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 9000L/h | |
Water pressure down | Kpa | 48 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY100D | |
Rated heating capacity | KW | 42 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY150D | |
Rated heating capacity | KW | 50 | |
Rated Cooling capacity | KW | 37 | |
Average input power | KW | 11 | |
Rated input current | A | 24 | |
Max outlet water temp | C | 38 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 18000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY200D | |
Rated heating capacity | KW | 84 | |
Average heating input power | KW | 19 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 28000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY300D | |
Rated heating capacity | KW | 100 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 45000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 |
Packaging & Delivery
Packaging Details: export wooden packing
Delivery Time: 15-30 days
Specifications
Swimming pool heat pump heating:
1. High efficiency & energy saving
2. Safe & Comfort
3. Convenient & widely to use
4. Swimming Pool Heat Pump heating:
|
|
|
Use
Business Organizations
Supermarket, shopping malls, shops, department store, star-rated
hotels, restaurants, school, office;
Public Places
subway, airports, stations, bookstores, exhibition halls, stadiums, museums, commercial buildings, hospital;
Entertainments Movie theaters, clubs, bars, cafes, Internet bars, beauty shops
Our Services
1. After installation, our company will be responsible for problems caused by quality of production or raw material except the damageable spare parts of heat pump caused by incorrect man-made operation during the guarantee period.
2. Intelligent Controlling service system will be avoid the long distance of the after sale problem. Wherever are you, our engineer can be controlled your equipment, when some questions occur on the equipment. Just tell us what number will be shown on the screen, then the engineer will be solve the problem.
3. We accept OEM, ODM and customization.
4. 24*7 after sales service. You will get satisfied service.
5. We have More than 17years production and sales experience; Professional sales team.