IMPORTANT SAFETY CAUTIONS
Skin Type
See skin color chart on page 1.
Do not use on naturally dark skin ( Fitzpatrick type V and VI) , as it may
result in burns, blisters and changes in skin color.
Do not use on tanned skin or after recent sun exposure, as it may
cause burns or skin injury.
PANDA BOX is not effective on naturally white, grey, blond or red body
hair.
Areas not to treat
Do not use on the face or the neck.
Do not use on nipples, areola, or genitals.
Do not use if you have tattoos or permanent makeup in the area to
be treated.
Do not use on dark brown or black spots such as moles, birth marks,
or freckles.
Do not use on an area of recent surgery, deep peel, laser resurfacing,
scars, or skin that has been damaged with burns or scalds.
When not to use/ When to avoid using PANDA
Do not use if you are pregnant or breast feeding.
Do not use if you were exposed to sun or artificial tanning within the
past 4 weeks.
Do not use on dry or fragile skin caused by the use of chemical peels,
glycolic peels, Alpha Hydroxy Acids ( AHAs) .
Do not flash more than once on the same area as this may cause burns.
Do not use on the same area of your skin more than once a week.
Do not use for at least 14 days following microdermabrasion treatment.
Do not use if you are already undertaking permanent hair removal
treatments
Do not use if you have a skin disease such as active skin cancer, if you
have a history of skin cancer or any other localized cancer in the areas
to be treated, or if you have pre-cancerous lesions or multiple atypical
moles in the areas to be treated.
Do not use if you have epilepsy with flashlight sensitivity.
Do not use if you have a history of collagen disorder, including a history
of keloid scar formation or a history of poor wound healing.
Do not use if you have a history of vascular disorder, such as the presence
of varicose veins or vascular ectasia in the areas to be treated.
IMPORTANT SAFETY CAUTIONS
Do not use if your skin is sensitive to light and causes a rash or an
allergic reaction. If you are taking photosensitizing agents or
medications, check the package insert of the medicine. Never use
the unit if it can cause photo-allergic reactions or photo- toxic
reactions, or if you should avoid sun while taking a medication.
Do not use if you have diabetes, lupus erythematodes, porphyria or
congestive heart disease.
Do not use on areas of your skin which are currently being treated
with or have recently been treated with Alpha Hydroxy Acids ( AHAs) ,
Beta Hydroxy Acids ( BHAs) , topical isotretinoin and azelaic acid.
Do not use if you have taken oral isotretinoin Accutane or Roaccutane
in the last six months. This treatment can make skin more susceptible
to tears, wounds and irritations.
Do not use if you have any bleeding disorder or take anticoagulation
medications, including heavy use of aspirin, in a manner which does
not allow for a minimum, 1-week washout period prior to each treatment.
Do not use if you have infections, eczema, burns, inflamed follicles,
open lacerations, abrasions, surgeries, herpes simplex, wounds or
lesions and haematomas in the areas to be treated.
Do not use if you have a history of immunosuppressive disease
( including HIV infection or AIDS) or if you take immunosuppressive
medications.
Do not use when you are on painkillers, which reduce the sensitivity
to heat.
Do not use if you use long-lasting deodorants. This can result in skin
reactions.
Do not use over or near anything artificial such as silicon implants,
Implanon contraceptive implants, pacemakers, subcutaneous injection
ports ( insulin dispenser) or piercings.
PREPARING FOR USE
A.PANDA Handpiece
B. Flash Button
C.Skin Contact Sensor
D. Flash Window
E.Nose Cone
F.Nose Cone Release Buttons
G.Light Cartridge
H. Handpiece Cord
I. PANDA Base Unit
J.Power Switch
K.Power Inlet
L. Intensity Level Selection Display
M.Flash Mode Selection
N.Power Cord
Familiarize yourself with the features of your new PANDA device.
Flash Window ( fig. 1-D)
The Flash Window is a filtered glass window with built-in UV protection
that allows specific wavelengths of light to pass from the hand piece to
your skin and hair follicles.
WARNING: Always inspect the Flash Window before use to ensure
there is no dam- age to the lens.
WARNING: Always clean the Flash Window before use with the lintfree
cloth pro- vided to ensure there is no oil or debris on the lens.
Skin Contact Sensor ( fig. 1-C)
The Skin Contact Sensor is a safety mechanism that prevents the device
from accidental activation. In order for the device to activate, the Skin
Contact Sensor must be fully depressed against the skin.
NOTE: If the Flash Button is pressed AND the Skin Contact Sensor
is not fully engaged OR the Bulb Status Indicator Display is not
illuminated, an audible beep will sound.
WARNING: ALWAYS ensure the unit is OFF and the power cord is
disconnected before removing the nose cone. If the nose cone is
removed while the unit is powered ON, all indicator lights on the
base unit will flash and audible beep will sound.
PREPARING FOR USE
Light Cartridge ( fig. 1-G)
Each light cartridge has a life of 1, 500 flashes. When all flashes have
been used, the cartridge must be replaced.
Intensity Level Selection ( fig. 1-L)
The PANDA device is equipped with 6 intensity levels. Level 1 is the
lowest set- ting and level 6 is the highest setting.
TIP: For the most effective results, always use the highest intensity
level that does not cause discomfort on the skin. To determine the
intensity level being used, observe the number of lights illuminated
on the Intensity Level Selection Display.
Your PANDA device will automatically be set to Intensity Level 1 each
time the device is powered ON. To change the level, press the Intensity
Level Selection Button.
Flash Mode Selection ( fig. 1-M)
The PANDA device is equipped with two operating modes: Single Flash
Mode and Multi-Flash Mode. Your PANDA device will automatically be
set to Single Flash Mode each time the device is powered ON.
Single Flash Mode: The PANDA device will flash once when the Flash
Button is pressed AND the skin contact sensor is engaged.
Multi-Flash Mode: The PANDA device will flash once every two seconds
when the Flash Button is pressed AND the skin contact sensor is fully
engaged.
The Multi-Flash Mode allows you to quickly treat large areas such as
the legs, chest or back by simply gliding the hand piece to a new location
after each flash.
To turn Multi-Flash Mode ON, press the Multi-Flash Mode Selector
Button. The Multi-Flash Mode Selector Display will illuminate. Press
again to turn Multi-Flash Mode OFF and return to Single-Flash Mode.
Getting Acquainted with PANDA
Test the PANDA device on your skin ( fig. 1)
1. Review the Warnings and Safety Precautions.
2. Familiarize yourself with the features of the PANDA device.
3. Consult the Skin Tone Chart to ensure your skin color is in the acceptable
range.
4. Test the PANDA device on a small patch of skin and wait 48 hours to
ensure there are no adverse reations.
Treat desired area( s) with the PANDA device
Prepare your skin for treatment
1. Ensure the area to be treated is clean and free from oils, deodorants, perfume,
make up, lotions and creams. Shave the hair from the area to be treated.
2. Never use wax, epilation, tweezers, or depilation products to remove the hair
because they counteract the IPL process.
Prepare the device for treatment
3.Unwarp the handle piece cord from the PANDA and rest the hand piece in the base
cradle. Locate the power switch on thePANDA base and ensure the unit is OFF.
Connect the power cord to the PANDA base at the power inlet. Connect the power
cord to the wall outlet. Turn the power switch ON.
4. Select the desired Intensity Level. If the Multi-Flash Mode is desired, turn on
using the flash mode selector button.
Getting Acquainted with PANDA
Treat desired area( s) with the PANDA device Single Flash Mode
1. Place the PANDA hand piece against your skin so the Flash Window
is flush with the skin surface ( fig. 2) .
2. Ensure the Skin Contact Sensor is fully engaged and the Bulb Status
Indicator Display is illuminated.
3. Press the Flash Button to activate the device ( fig. 3) .
4. Move the hand piece to a new treatment area and repeat steps
1-3 ( fig. 4) .
Treat desired area( s) with the PANDA device Multi Flash Mode
1. Place the PANDA hand piece against your skin so the Flash Window
is flush with the skin surface ( fig. 1) .
2. Ensure the Skin Contact Sensor is fully engaged and the Bulb Status
Indicator Display is illuminated.
3. Press AND HOLD the Flash Button down to activate the device ( fig. 2) .
4. Immediately after the device has flashed, slide the hand piece to a
new location. After a short delay ( approximately 2 seconds) the device
will flash again ( fig. 3) .
NOTE
During Multi-Flash Mode, the Skin Contact Sensor AND the Flash
Button must remain fully depressed. If either becomes disengaged,
the device will not oper- ate. To resume treatment, repeat steps 1-4.
During Multi-Flash Mode, the Bulb Status Indicator Display will
remain illuminated while the Skin Contact Sensor and Flash Button
are engaged.
Model Number: HTI019
Brand Name: HT
Payment Terms: TT/ the West
Minimum:
Certification: CE
Delivery Time: 3--7 working days after the payment
Supply Ablity:

Hot Products

Detail: Portable 2 in 1 RF Wrinkle Removal Beauty Machine and fat burning, body shaping System 2 in ...
Detail: Portable 1.2A 50 - 60 Hz Skin facial toning device IPL Laser Equipment for wrinkle removal ...
Detail: 110W Ultrasonic Vacuum Cavitation Slimming Beauty Equipment Machine for skin tightening 1. ...
Detail: 5.2' ' 400W two hand IPL Laser Equipment Beauty Machine for Remove facial vascular lesions 1...
Detail: multi-polar RF equipment Specifications RF machine multi polar RF machine 1. Tri-polar RF ...
Detail: Mini IPL beauty machine for hair removal and skin rejuvenation sale 1.Theory of operating: ...