Digital Vibration Calibrator Calibrate Vibration Meter Vibration Analyzer Vibration Tester ISO10816

 

 

Application for ISO10816 HG-5010 Vibration Calibrator:

1.Can be used to calibrate vibration accelerometer, velocity and proximity transducer and also a vibration measuring instruments. Standard sine signals at frequency 10, 20, 40, 80, 160, 320, 640 and 1280 Hz

2.Can be generated from the calibrator the amplitude of the acceleration, velocity and displacement

3.Can be defined through potentiometers and shown on digital displays. Either horizontal or vertical vibration can be generated.

4.HG-5010 vibration calibrator combines sine signal generator, power amplifier, standard transducer and a shaker in one and features a small volume, high accuracy and easy operation. It can be used either in laboratory or on site.

5. International standards: ISO10816

 

Specifications:

 

Frequency: 10, 20, 40, 80, 160, 320, 640, 1280Hz +0.01%

Unit:

Acceleration:   m/s (PEAK)

Velocity:       mm/s (RMS)

Displacement:  um   (PK-PK)

Amplitude accuracy:

Acceleration (30m/s2 pk, 80Hz) 40Hz to 320Hz + 0.3dB + 1digit

10Hz to 6400Hz + 0.5dB +1digit

Velocity ( 25mm/sec pk ,80Hz) 40Hz to 320Hz +0.5dB +1digit

Displacement (10μm pk-pk, 80Hz) 40Hz to 320Hz + 0.5dB + 1digit

Proximity probe linearity

Prode: 5mm and 8mm probes Range: 0~4.0mm

Display: 3 1/2 digit display for acceleration, velocity or displacement

Maximum vibration amplitude and maximum load:

Because of the vibrostand used in HG-5010 Vibration Calibrator is rather small, during the calibration of transducers of different weight under different frequencies the output amplitude of the calibrators are also different. Maximum vibration amplitude and maximum load are related to the maximum acceleration. Maximum velocity and maximum displacement output generated from the calibrator under a certain frequency and with a certain weight of the transducer to be calibrated. The specific figures can be seen in the following table.

Wt

 

Freq

<100g<250g<650g
a(m/S2)v(mm/S)d(μm)a(m/S2)v(mm/S)d(μm)a(m/S2)v(mm/S)d(μm)
10Hz2.52813003.54018004452000
20Hz1585190010601300528640
40Hz6017020003510011001235380
80Hz10014180040603201420110
160Hz7553150352570128.524
320Hz501825301015103.55
640Hz3053203.5261*
1280Hz232*100.9*50.4*

Note: With higher frequency the value of the displacement of vibration is very small so there will be no vibration signal output from the calibrator.

 

Size: 280 x 180 x 250(mm)

Weight: 20lb,9kgs

Temperature: Operation: 0oC to 50 oC

Storage: -20 oC to 70 oC

Humidity: 90% non -condensing

 

The control panel of HG-5010 Vibration Calibrator is shown as following:

 

1 Vibration amplitude output display Showing the amplitude of the different vibration signal output of the calibrator

2 Calibration potentiometer

3 Function selecting switch   Shifting the output of the calibrator to acceleration, velocity or displacement

4 Potentiometer for adjusting the output amplitude

   Adjusting the potentiometer to change the output vibration amplitude

5 Adjusting the the output vibration amplitude slowly

6 The table for fixing the transducer to be calibrated

7 The thread hole for fixing the stand of proximity probe

   During the calibration of proximity probe, the stand of the transducer is fixed on the control panel  through this thread hole.

8 Power switch 220 VAC

9 Socket for 220 V AC power input

   Used for connecting 220 V AC power.

10. Socket for power output

     For monitoring the wave shape of the output signal of the power amplifier of the calibrator.

11 Output socket of – 24 V voltage

   Providing power at – 24 V for proximitor during the calibration of proximity probe.

12 Frequency selecting switch

 

 

1

 

 

Fixing stand

2

 

 

 

Spindle micrometer

3

 

 

 

Tool to fix the sensor

4

 

 

 

Testing plate

5

 

 

 

M5 Fixing screw

6

 

 

 

M5-M8 Transition screw

7

 

 

M5-M10 Transition screw

 

 

 

We also offer vibration calibration system for more high accuracy as below photo:

 

 

Hot Products

BNC Cable Connectors Ultrasonic Flaw Detection Microdot MD Lemo 00 Lemo 01, Subvis connector, RG174 ...
Piezoelectric Ceramics Flaw Detector Ultrasonic Crystal Element Probe Transducers Piezoelectric ...
FD520 digital ultrasonic flaw detector , ultrasonic flaw detection equipment dust proof Main ...
Portable Digtal flaw detector ultrasonic FD510 , High Resolution, Crack inspection, Welding ...
Elevator Wire Rope Detector Steel Rope Wire Rope Internal External Flaw Detector HRD-150 Elevator ...
Mining Ropes Wire Rope Flaw Detector Cableway Elevator Wire Rope Flaw Detector Steel Rope Flaw ...