HQM-A Modular UPS 60-300kVA

City & Province shenzhen guangdong
Categories Electronic Signs
InquireNow

Product Details

 
30kVA UPS Power Module, Double DSP control
Scalable from 30 kVA to 300kVA. Parallel-capable up to 2400 kVA.
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
 
HQM-A MODULAR UPS 30-300kVA,0.9PF
3:3Phase,208Vac/208Vac
Truly modular UPS
 
Full functioned UPS Module
 
HQM-A modular UPS is double DSP controlled green UPS, adopted with double high speed DSP to ensure its excellent performanc,reliability and flexibility. It delivers the best combination of rectifier, filter, charger, inverter and intelligent power protection. Applying innovated current sharing rectifier control, master-slave synchronization in sequence control, multi-level decentralized control and 3-level inverter technolog,
HQM Modular architecture can scale power as demand grows or as higher levels of availability are required.
 
 
Main Features:

  • Great performance index, 7inch touch screen
  • overall efficiency ≥ 95%(AC-AC), inverter efficiency ≥ 98%(DC-AC), THDI ≤ 3%, and input PF ≥ 0.99

  • N+X module-level redundancy UPS System
  • Multi-level decentralized control technology and Master-slave synchronization in sequence control which result in eliminate system failure bottleneck
  • Each Power module can work separately with LCD display
  • And automatically shares the input and output current, all UPS modules share batteries
  • Intelligent Battery management:
  • Battery discharge management, auto-transfer between floating and even charging, temperature compensation
  • Space-saving high density design, Rack-based for agility and aesthetics
  • Abundant Monitor Function

 
30 kVA UPS module (PMA3330)

  • Adaptable 30 to 300 kVA power capacity
    30 kVA UPS module
    Components: STS module, Monitor module, UPS module,

    Power distribution
    Top or bottom feed
    Module dimension(D*W*H):580x443x225mm

  •  

 
UPS MODULE TECHNICAL SPECIFICATION:

Power Rating60kVA90kVA120kVA150kVA180kVA300KVA
60kVA/54kW90kVA/81kW120kVA/108kW150kVA/135kW180kVA/162kW300kVA/270kW
Main Input
Grid System3 Phases + Neutral + Ground
Rated Input Voltage200/208/220VAC (Line-Line)
Rated Frequency50/60Hz
Input Voltage Range166~261Vac (Line-Line),full load
125V~166Vac (Line-Line),load decrease linearly according to the min phase voltage
Input Frequency Range40Hz~70Hz
Input Power Factor>0.99
Input Current THDi<3% (full Linear Load)
Bypass Input
Rated Bypass Voltage200/208/220VAC (Line-Line)
Rated Frequency50/60Hz
Bypass Voltage RangeSelectable, default -20%~+15%
Upper limit: +10%, +15%, +20%, +25%
Lower limit: -10%, -15%, -20%, -30%, -40%
Bypass Frequency RangeSelectable, ±1Hz, ±3Hz, ±5Hz
Bypass Overload125%, long time operation
125%< load <130%, last for more than 10 minutes
130%<load<150%,last for more than 1 minutes
>1000%, last for more than 100ms
110% Long term operation
110%~125% for 5min
125%~150% for 1min
150%~400% for 1s
>400% ,less than 200ms
Output
Rated Inverter Voltage200/208/220VAC (Line-Line)
Rated Frequency50/60Hz
Output Power Factor0.9
Voltage precisionBalance load: ±1%; Unbalance load: ±1.5%
Transient Response<5% for step load (20% - 100% -20%)
Transient recovery< 30ms for step load (0% - 100% -0%)
Output Voltage THDu<1.5% from 0% to 100% linear load
<6% full non-linear load according to IEC/EN62040-3
Inverter Overload<110%, 60min;
110%~125%,10min;
125%~150%,1min;
>150%,200ms
Frequency Regulation50/60Hz±0.01%
Synchronized RangeSettable, ±0.5Hz ~ ±5Hz, default ±3Hz
Synchronized Slew RateSettable, 0.5Hz/S ~ 3Hz/S, default 0.5Hz/S
Battery And Charger
Battery Rate Voltage±120VDC
Charger Voltage precision1%
Charger Powermax=20% *Output power
Efficiency
Normal Operation>93%
Battery Operation>93%
System
DisplayLED + LCD + touch screen
InterfaceStandard:RS232, RS485, USB,Dry contact(Programmable )
Optional:Battery Cold Start(Standard above 150kVA)
SNMP,AS400,parallel kit,Lightning protection components
Environmental
Operation Temperature0 ~ 40 ℃
Storage Temperature-40 ~ 70 ℃
Relative Humidity0 ~ 95% Non condencing
Noise (1 meter)65dB @ 100% load, 62dB @ 45% load
Altitude<1000m, Load derated 1% per 100m From 1000 ~ 2000m
Phisical data

Dimension
(W*D*H,mm)

600*980*1150650*960*2000650*960*1600650*960*2000650*960*20001300*1100*2000
Weigh (kg)210305350445490900





































Hot Products

Smart Portable power bank station, with USB output, DC output and AC output for home appliance. ...
THC Series POWER INVERTE 500W-3000W For Home Application THC Series Power Inverter 150-3000VA with ...
The PG plus series inverter is a transformerless and economical inverter ,which is mainly designed ...
ECO Series DC UPS Main Features: 19inch,2U and 3U Rack mount High frewuency and online double ...
Perfect Application: PC,office,communication switching system,server, lan equipment, ATM system etc. ...
PCM Rack Series 1-10kVA,1.0PF System introduction: PCM Rack Series is a full DSP controlled, adopted ...