Home Companies Beijing HiYi Technology Co., Ltd

Chloramphenicol Test Strip Fresh Raw Milk Milk Powder Pasteurized Milk Clear Easy To Interpret Visual Results

Beijing HiYi Technology Co., Ltd

Contact Us

Trade Verify

Address: Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China

Contact name:Lisa Niu

Inquir Now

Beijing HiYi Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Chloramphenicol Test Strip Fresh Raw Milk Milk Powder Pasteurized Milk Clear Easy To Interpret Visual Results

City & Province beijing beijing
InquireNow

Product Details

 

Chloramphenicol Test Strip For Dairy Products

 

OVERVIEW

 

Chloramphenicol antibiotics can act on the 50S subunit of bacterial ribonucleoproteins and hinder the synthesis of proteins.Chloramphenicol antibiotics include chloramphenicol, sulfomycin, and odorless chloramphenicol.

 

 

Single Test Kit, rapid to detect an Chloramphenicol residues in milk and dairy product by using fluorescent immunochromatography technology. As soon as 7-10 minutes to results.

 

 

 

FEATURES & BENEFITS

 

Product Introduction:

  • This product uses lateral chromatography to quickly detect aflatoxin M1 residues in bovine and sheep milk.

Performance Description:

  • Detection limit: 0.08 ~ 0.1 μ g/kg
  • Specificity: This product is similar to tetracyclines β- There was no cross reaction between lactam, quinolone, aminoglycoside antibiotics and melamine

Experimental Preparation:

  • Restore the sample and kit to room temperature.

Operation Steps:

  • Open the test paper barrel and take out the required number of micropores. Put the rest back into the test paper barrel and cover it to prevent the reagent in the test paper barrel from getting wet.
  • Mix the sample evenly and suck 200 μ L in micropores, blow and mix evenly for 5 ~ 10 times, and incubate at 40 ℃ for 3min.
  • Take out the required number of test strips, cover the end of the test strip barrel, and then mark one end of the absorbent paper of the test strip.
  • Insert one end of the sample pad of the test strip into the micropore and react at 40 ℃ for 6min.
  • Take out the test strip and interpret the results within 2 minutes (interpretation at other times is invalid).

Interpretation:

  • Visual inspection

         1. If C line visible, interpret according to the instruction. T line compare with C line to interpret positive or negative.

        2. If C & T are invisible, it’s invalid detection, repeat testing again.
            Reader Interpretation
            Refer to the instruction
            Results Illustration

 

Precautions:

  • Do not mix different batches of test strips and micropores.
  • It is recommended to wear clean disposable gloves for operation.
  • Retest the positive test results.
  • The reagent barrel shall be used up within 1 week after opening, and the unused reagent shall be stored at 2 ~ 8 ℃.
  • This product is only used for preliminary screening.

 

  •   
SPECIFICATION

 

Spicifications

1. Specificity

Not cross-react with macrolides, trimethoprim, sulfonamides drugs, etc.
2. Limit of Detection
Refer to instruction.

Storage & Shelf-Life
At 2~8℃ out of sunlight, 12 months

Compolents (96T / box)
Instruction 1
Tube 12

Equipments (Option)
Timer
Incubator
Mini Pipette(200μL)
Tips for mini pipette
Reader

 

 

APPLICATION  

 

For raw milk, whole milk powder, Pasteurized milk.

 

Hot Products

KANE458s Flue Gas Analyser with direct CO2, CO & over-range protection OVERVIEW Test domestic gas, ...
KANE 358 Flue Gas Analyser with CO sensor protection OVERVIEW KANE358 has a large 6 line display ...
KANE458s IAQ Indoor Air Quality Analyser FGA & IAQ Analyser measuring O2, CO & ambient CO2 OVERVIEW ...
KANE958 Commercial Analyser Flue Gas Analyser with direct CO O2 & CO sensor protection OVERVIEW ...
KANE988 Industrial Flue Gas Analyser With High Suction Pump FEATURES * Tests any boiler up to & over ...
KANE988+ Boiler Engine & A/C Refrigeration Analyser OVERVIEW Test any size boiler with high suction ...