Home Companies Beijing HiYi Technology Co., Ltd

5ul To 5ml Autoclavable Pipette For Analytical Chemistry

Beijing HiYi Technology Co., Ltd

Contact Us

Trade Verify

Address: Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China

Contact name:Lisa Niu

Inquir Now

Beijing HiYi Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

5ul To 5ml Autoclavable Pipette For Analytical Chemistry

City & Province beijing beijing
Categories Other Plastic Products
InquireNow

Product Details

MicroPette Plus Fully Autoclavable

Single-Channel Mechanical Pipette

 

OVERVIEW

 

The MicroPette Plus pipettes are fully autoclavable, enable easy cleaning and reduce the risk of contamination. Steam autoclaving can be performed at 121°C, 1 bar for 20 minutes. After autoclaving, the pipette must be cooled down and left to dry for 12 hours before use. It is recommended to check the performance of the pipette after each autoclaving. Greasing and sealing of the pipette piston after every 10th autoclaving will secure an enhanced function.
 
FEATURES
 
* Central, large pipetting button for smooth movement of the piston
* Smooth knob adjustment for light and smooth range adjustment
* Easy volume adjustment for left- and right-handers
* Large, ergonomic ejection button for rapid replacement of the tips
* Ergonomic finger rest that allows comfortable handling
* Precise, digital volume display
* Lightweight but still robust for easy tip selection
* Compatible with most universal tip brands
* Fully autoclavable at 121 °C with use of best in class innovative materials
* Corrosion-resistant piston & ejector complying to European standard
* Online calibration available
* Individual calibration certificate provided according to ISO8655
* Best suited for clinical diagnostics and control analysis labs.
* Best suited for molecular biology, microbiology, immunology, cell culture, analytical chemistry, biochemistry and genetic labs.
* Best suited for ELISA & CLIA diagostics test, molecular screening, kinetic studies, DNA application etc.
* Available as Fixed Volume and Variable Volume formats
* Streamlined shape design
* Comprehensive volume range from 0.1μL to 5mL
* Easy calibration and maintenance
* 8 and 12 channel pipette options
* Dispensing head rotates for effortless pipetting convenience
* Individual piston and tip cone assembly
* Spring loaded tip cones for easy cleaning and maintenance
* Compound material-made tip cone secures high sealing performance
 
SPECIFICATION

 

Volume Range
Increment
Test Volume(μl)
Accuracy error
Precision error
 
 
 
%
μl
%
μl
0.1-2.5μl
0.05μl
2.5
2.50%
0.0625
2.00%
0.05
1.25
3.00%
0.0375
3.00%
0.0375
0.25
12.00%
0.03
6.00%
0.015
0.5-10μl
0.1μl
10
1.00%
0.1
0.80%
0.08
5
1.50%
0.075
1.50%
0.075
1
2.50%
0.025
1.50%
0.015
2-20μl
0.5μl
20
0.90%
0.18
0.40%
0.08
10
1.20%
0.12
1.00%
0.1
2
3.00%
0.06
2.00%
0.04
5-50μl
0.5μl
50
0.60%
0.3
0.30%
0.15
25
0.90%
0.225
0.60%
0.15
5
2.00%
0.1
2.00%
0.1
10-100μl
1μl
100
0.80%
0.8
0.15%
0.15
50
1.00%
0.5
0.40%
0.2
10
3.00%
0.3
1.50%
0.15
20-200μl
1μl
200
0.60%
1.2
0.15%
0.3
100
0.80%
0.8
0.30%
0.3
20
3.00%
0.6
1.00%
0.2
50-200μl
1μl
200
0.60%
1.2
0.15%
0.3
100
0.80%
0.8
0.30%
0.3
50
1.00%
0.5
0.40%
0.2
100-1000μl
5μl
1000
0.60%
6
0.20%
2
500
0.70%
3.5
0.25%
1.25
100
2.00%
2
0.70%
0.7
200-1000μl
5μl
1000
0.60%
6
0.20%
2
500
0.70%
3.5
0.25%
1.25
200
0.90%
1.8
0.30%
0.6
1000-5000μl
50μl
5000
0.50%
25
0.15%
7.5
2500
0.60%
15
0.30%
7.5
1000
0.70%
7
0.30%
3

 

 

 

 

FAQ

Q1:How to use Pipette?

A: This is the standard technique for using a graduated pipette :

Hold pipette in solution, don’t touch the bottom.
Squeeze bulb and attach to top of the pipette.
Hold forefinger on top of pipette to control volume aspiration.
Subtract the amount needed into separate beaker while staying eye level to assure proper measurement.

 


Q2: Why is a Pipette more accurate than a Buret?
A:Burettes have a stopcock at the bottom while a pipette has a dropper like system that releases liquid in the desired amount by lessening the vacuum. Furthermore, a pipette is smaller than burette. As another important difference between burette and pipette, pipettes are more accurate in releasing liquid in smaller quantities than burettes.

 

Hot Products

KANE458s Flue Gas Analyser with direct CO2, CO & over-range protection OVERVIEW Test domestic gas, ...
KANE 358 Flue Gas Analyser with CO sensor protection OVERVIEW KANE358 has a large 6 line display ...
KANE458s IAQ Indoor Air Quality Analyser FGA & IAQ Analyser measuring O2, CO & ambient CO2 OVERVIEW ...
KANE958 Commercial Analyser Flue Gas Analyser with direct CO O2 & CO sensor protection OVERVIEW ...
KANE988 Industrial Flue Gas Analyser With High Suction Pump FEATURES * Tests any boiler up to & over ...
KANE988+ Boiler Engine & A/C Refrigeration Analyser OVERVIEW Test any size boiler with high suction ...