City & Province beijing beijing
Categories Other Plastic Processing Machinery
InquireNow

Product Details

 
Staphylococcus Aureus Count Plate

 

OVERVIEW

 

Staphylococcus Aureus (abbreviated as S. aureus) is one of the most common pathogenic bacteria for human beings. Its invasion ability is very strong by the means of production of a variety of pathogenic substances, such as enterotoxin and coagulase. It can cause suppurative inflammation, toxin disease and staphylococcal enteritis. The poisoning events caused by S. aureus has become a worldwide public health issue. In China, such food poisoning caused by S. aureus has been reported frequently every year.
Each Staphylococcus Aureus Count Plate is a pre-prepared disposable culture system that contains nutrients, water-soluble gelling agent, and indicator---all the components needed for microbial growth with, so no agar preparation is required.
The Staphylococcus Aureus Count Plate makes the total Staphylococcus Aureus counting finished in as soon as 15hrs. Enhanced visualization simplifies the interpretation as the positive colonies colored in violet red on the test plate.

 
FEATURES & BENEFITS

 
1. Time-saving, Coliform and E. coli count can result in as soon as 15hrs.
2. Ready for use, eliminating the cumbersome steps of preparing microbial media.
3. Unique miniature petri dish, scientific design ensures good performance on safety
4. Clearer bacterial spot, easier for observation and color interpreted
5. Decades of R&D experience since 1993, professional brand and reliable quality, good reputation.

 
Storage and Stability:
1. Store at a temperature between 4 to 10℃ with intact packages.
2. Prior to use, warm up to room temperature before opening.
3. Once opened, fold over the pouch and seal it by adhesive tapes to prevent exposure to ambient moisture. The kit can be store in a cool, dry place for no longer than 4 weeks. Or place the pouch in a sealed container and store in a refrigerator.
4. Under sealed condition at room temperature, transportation period should be less than 15 days to make sure the product performance remains stable.

 


 
Inoculate:

uncover the top film of the plate, pipette 1ml of sample and drip it onto the center of the plate vertically.
Incubate:

put the plates (film upwards, piled less than 12 pieces) into the incubator (36±1℃) and incubate for 15-24hrs.
Interpret:

count the red and blue colonies with gas bubbles separately, and the fast, precise, and consistent results can be obtained with the help of a built-in grid. (Note: Coliforms are red colonies, while E. coli are blue colonies).
 

SPECIFICATIONS

 

Catalog No.: MC32.8018.5
Quantity : 24 pieces.
Storage Conditions: 4~10℃
Shelf Life : 18 months
Production Dates: On the seal
 
Pathogens Microbial Count Plate Series Products
SN
Product Name
Applications
1
Aerobic Count Plate
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.
2
Coliform & E. coli Count Plate
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.
3
Coliform Count plate
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.
5
Enterobacteriaceae Detecting Board
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.
6
Salmonella Count Plate
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.
7
Staphylococcus aureus Count Plate
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.
8
Yeast & Mold Count Plate
Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed,
poultry, prepared & processed food, and seafood, etc.

 

 

 

APPLICATION

 

Bakery, beverage, bottled water, confectionary, dairy, eggs, fruits, vegetables, meat, nutraceuticals, pet food, animal feed, poultry, prepared & processed food, and seafood, etc.
Food manufacturers and processors, food safety testing, environmental monitoring, centers for disease control and prevention (CDC), market supervision and government inspection labs, etc.
 
 

Hot Products

KANE458s Flue Gas Analyser with direct CO2, CO & over-range protection OVERVIEW Test domestic gas, ...
KANE 358 Flue Gas Analyser with CO sensor protection OVERVIEW KANE358 has a large 6 line display ...
KANE458s IAQ Indoor Air Quality Analyser FGA & IAQ Analyser measuring O2, CO & ambient CO2 OVERVIEW ...
KANE958 Commercial Analyser Flue Gas Analyser with direct CO O2 & CO sensor protection OVERVIEW ...
KANE988 Industrial Flue Gas Analyser With High Suction Pump FEATURES * Tests any boiler up to & over ...
KANE988+ Boiler Engine & A/C Refrigeration Analyser OVERVIEW Test any size boiler with high suction ...