UVOZ-3000 Ozone Detector

OVERVIEW

 

This ozone concentration analyzer adopts dual optical path UV light source system, with UV LED light source management system inside, the UV LED lamp can reach the measurement state within 1 minute after powering on, and adopts separated gas chamber and light cell design structure, the gas chamber has the features of no leakage, high pressure resistance, resistance to the impact of ozone gas of large flow rate, easy to clean, easy to maintain, easy to operate, and low cost of use. Mainly used for continuous detection of various industrial environments to detect the concentration of ozone gas production, ozone generator outlet concentration measurement, so as to calculate the ozone generator feeding production, can also be used for pipelines and containers in the ozone gas concentration analysis and detection.

 

FEATURES

 

With touch screen operation interface, real-time display of ozone gas concentration, with pressure and temperature compensation and display, automatic calibration time and manual calibration mode can be set.


High concentration range (g/Nm3, mg/NL) with flow input function, real-time display of ozone generator output.


With two groups of relay signal output, users can freely choose the high alarm point and low alarm point signal output.


Core sensor components using foreign UV LED light source, foreign photoelectric receiver components, dual-optical sampling structure, according to foreign instruments designed and developed independently of the gas chamber sealing structure of the gas chamber and the light cell structure, with pressure resistance, impact resistance and other characteristics, the use of an independent light cell and the gas chamber of the structure of the way, easy to maintain and replace.


It is equipped with automatic zero correction function to ensure the stability of the zero point and prevent the zero point deviation from affecting the accuracy of the detection concentration, and the gas flow, pressure and flow rate remain unchanged during the zero calibration operation to prevent the impact of the gas flow from affecting the zero calibration, and the zero calibration operation can be completed without shutting down the ozone inlet to ensure that the Ozone Concentration Analyzer can be operated continuously for 24 hours a day.

 

 

PARAMETER

 

 

modelUVOZ-3300C
Measure the range0-300g/Nm3
Optional range0-400g/Nm3;0-200g/Nm3;0-100g/Nm3;0-50g/Nm3;0-10000ppm;
Light source lifeAbout 30,000-50,000 hours;
Sampling methodPositive pressure sampling, negative pressure sampling (optional);
Display interface4.3-inch touch screen operation interface;
Content interfaceOzone concentration, temperature, pressure; (yield calculation and data recording can be customized)
additional functionTemperature compensation, pressure compensation;
Display unitOption of g / Nm 3, mg / NL,% WT;
display resolution0.01g/Nm3;
gas-flow rate0.5L±0.2L/min;
input pressure<0.1MPa;
Concentration error≤0.5%FS;
linear error≤0.5%FS;
precision≤±3%
zero drift<±0.3%.FS;
reaction timeSignal 0.03 seconds, display 0.3 seconds;
ambient temperature-20~50℃
Pipe interface modeQuick twist (stainless steel);
Tandem sample caliberΦ 8 (8mm * 6mm) (optional);
Bypass sampling caliberΦ6(6mm*4mm);
communication modeRS-485;
Output method4-20 mA (active);
Following the electrical signalHigh alarm point following the electrical signal, low alarm point following the electrical signal;
sourceAC 110-220V;
size

133mm (height) 482mm (width) 300mm (deep), 19-inch 3U chassis;

(Note 1 mg/L = 1 g/m3 = 467 PPM);

Free warranty24 months (host sensor);

 

 

APPLICATION

 

Ozone generator manufacturers,

Municipal water industry,

Industrial wastewater industry,

Fine chemical industry,

Food and drinking water industry,

Space disinfection industry,

Swimming pool disinfection industry,

Flavor synthesis industry ,

other industries using ozone generators.

 

 

 

 

 

 

 

Hot Products

MS104K-S Portable Diffusion Gas Detector OVERVIEW MS104K-S portable gas detector adopts a high...
MiniGas Single Gas Detector OVERVIEW MiniGas is small, sturdy, ergonomic, and can be attached to a ...
UVOZ-3300C Ozone Gas Analyzer OVERVIEW The UVOZ-3300C ozone gas analyser has a touch screen operator ...
UVOZ-3300C Ozone Gas Analyzer OVERVIEW The UVOZ-3300C ozone gas analyser calculates the current ...
UVOZ-3300C Ozone Gas Analyzer OVERVIEW TUVOZ-3300C ozone gas analyser mainly used for continuous ...
UVOZ-1200C Ozone Gas Analyzer OVERVIEW The UVOZ-1200 The core component adopts UV long life light ...