Home Companies Wuhan Huaying Electric Power Tech & Science Co., Ltd

High Precision Current Transformer Testing Equipments CT PT Set ISO Approve

Wuhan Huaying Electric Power Tech & Science Co., Ltd
Active Member

Contact Us

[China] country

Address: 4F,Building 7,Optical Valley International Headquarters Industrial Park,No.62,Optical Valley Road,Wuhan,China

Contact name:

Inquir Now

Wuhan Huaying Electric Power Tech & Science Co., Ltd

High Precision Current Transformer Testing Equipments CT PT Set ISO Approve

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

High Precision Current Transformer Testing Equipments CT PT Set ISO Approve

 

 

Equipment Description:

HYVA-405 is a versatility current and voltage transformer characteristics tester in accordance with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC60044-6 / GB16847 and C57.13, the instrument can obtain excitation characteristic of current and voltage transformer, excitation parameters, turns ratio, turns ratio error, polarity, coil resistance, hysteresis loop lines and other various experimental parameters, the measured current transformer inflection point voltage can reach up to 45KV.

Applications of CT/ PT Analyzer:
1  CT nameplate check
2  CT parameters check in work burden
3  CT transient parameters analysis
4  CT ratio and phase error calibration
5  PT routine test

 

Technical Parameters:

1. input voltage: AC220V ± 10%, 50Hz / 60Hz ± 10%
2. output voltage: 0.1 ~ 180V (AC)
3. output current: 0.001 ~ 5A (RMS)
4. output power: 500VA
5. the maximum equivalent inflection voltage: 45KV
6. the current measurement: Range: 0 ~ 10A (autoranging 0.1 / 0.4 / 2 / 10A)
7. the voltage measurement: Range: 0 ~ 200V (autoranging 1/10/70 / 200V)
8. turns ratio measurement: Range: 1 to 35,000,
9. phase measurement: Accuracy: ± 2min, Resolution: 0.01min
10. secondary winding resistance measurement range: Range: 0 ~ 8KΩ (autoranging 2/20 / 80Ω / 800Ω / 8kΩ)
11. Working conditions: Temperature: -10 ℃ ~ 50 ℃, humidity: ≤90%
12. Size: 485mm × 356mm × 183mm
13. Weight: 15Kg

CT / PT Analyzer can also be used in the following voltage transformer tests:

1) PT turns ratio detection

2) PT polarity check

3) PT secondary winding resistance measurement

4) PT secondary load measurement

  

 

 

Hot Products

Three Phase High Voltage Tester AC Resonance Test Set For AC High Voltage Withstand Test 1. Product ...
HV Adjustable Variable Frequency Hipot Test Set Adjustable Series Resonance Test Set Product Name: ...
Light Weight High Voltage Hipot Tester AC Resonant Test System Tester 1. Product Name:Series AC ...
50 KV Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System 1. Product Name:Series ...
Frequency Adjustable Series Resonant Test System High Voltage Testing Machine 1. Product Name...
50 HZ 30 KV Hipot Test Set Insulating Gloves Boots Withstanding Tester Introduction HYDZ insulating ...