Wuhan GDZX Power Equipment Co., Ltd |
Verified Suppliers
|
|
5kV 10kv 20kV Portable High Voltage Withstanding Tester Hipot Tester
This high voltage withstanding test (also called dielectric
strength test, hi-pot test, hi-pot test, breakdown test or flash
test) is widely used in electrical appliances, rubber-wooden
facility, transformer, wires, power meter, motor, source
jack-socket, cables and all kinds of electronic and electrical
products. Our product is the ideal instrument for such test.
The withstand voltage tester is an instrument for measuring the
withstand voltage. It can intuitively, accurately, quickly and
reliably test the electrical safety performance indicators such as
breakdown voltage and leakage current of various objects to be
tested, and can be used as a high voltage source to test the
element. Device and overall performance. The pressure tester is
designed in accordance with international and domestic safety
standards such as IEC, CSA, UL, JIS, and withstand voltage output
of 1kV~50kV and leakage current of 0~200mA. Suitable for all kinds
of household appliances, power switches, wire and cable,
transformers, terminal blocks, high-voltage bakelite electrical
appliances, motors, medical, chemical, instrumentation, etc., as
well as the test of safe withstand voltage and leakage current of
high-voltage systems, and also a research laboratory And the
pressure test equipment is indispensable for the technical
supervision department.
The pressure tester product is based on the absorption and
digestion of advanced pressure testers at home and abroad, combined
with the actual use of many users to improve and perfect the
design. The test voltage and leakage current are displayed at the
same time. The function is rich and practical. It can reflect the
actual value of the leakage current of the measured body through
the leakage current display and compare the pressure resistance
between different batches of different products or different
manufacturers to ensure the safety of your product. The performance
is flawless, and it is at the domestic leading level in terms of
technical performance and quality reliability.
Model Series:
Model / Spec | AC | DC | ||||
5KV | 10KV | 20KV | 5KV | 10KV | 20KV | |
ZX2670A | 20mA | -- | -- | -- | -- | -- |
ZX2671A | -- | 20mA | -- | -- | 10mA | -- |
ZX2671B | -- | 50mA | -- | -- | 20mA | -- |
ZX2671C | -- | 100mA | -- | -- | 20mA | -- |
ZX2672A | 20mA | -- | -- | 10mA | -- | -- |
ZX2672B | 100mA | -- | -- | -- | -- | -- |
ZX2672C | 100mA | -- | -- | 20mA | -- | -- |
ZX2672D | 200mA | -- | -- | 20mA | -- | -- |
ZX2674A | -- | -- | 20mA | -- | -- | 10mA |
Mode
Technical parameter of ZX2670A,ZX2672A,ZX2672B,ZX2672C,ZX2672D
Items | Model | ZX2670A | ZX2672A | ZX2672B | ZX2672C | ZX2672D | |
ACW | Output voltage range | (0.00~5.00)kV | |||||
Maximum output power | 100VA (5.000kV/20mA) | 500VA (5.0kV/100mA) | 1000VA (5.0kV/200mA) | ||||
Maximum rated current | 20mA | 100mA | 200mA | ||||
Current stalls | 2mA,20mA | 2mA,20mA,100mA | 2mA,20mA,200mA | ||||
Output waveform | Sine wave | ||||||
Output waveform distortion | ≤5%(No-load or pure resistive load) | ||||||
Test time | 0.0s~999s 0.0=continuous test | ||||||
DCW | Output voltage range | ———— | (0.00~5)kV | ———— | (0.00~5.00)kV | ||
Maximum output power | ———— | 50VA(5kV/10mA) | ———— | 100VA(5.00kV/20mA) | |||
Maximum rated current | ———— | 10mA | ———— | 20mA | |||
Current taps | ———— | 2mA,10mA | ———— | 2mA,20mA | |||
Ripple factor | ———— | ≤5% | ———— | ≤5% | |||
Test time | ———— | 0.0s~999s 0.0= Continuous test | ———— | 0.0s~999s 0.0=continuous test | |||
V | Range | (0.00~5.00KV) | |||||
accuracy | ±(5%+3 words) | ||||||
Resolution | 10V | ||||||
Display the value | Root mean square value | ||||||
A | measuring range | AC | 0.100mA~20.0mA | 0.100mA~100mA | 0.1mA~200mA | ||
DC | ———— | 0.1mA~10.0mA | ———— | 0.100mA~20.0mA | |||
Resolution | 2mAfile:1uA,20mA file:10uA,100mA(200mA) file:0.1mA | ||||||
measurement accuracy | ±(5%+3 words) | ||||||
Timer | range | 0.0s~999s | |||||
Minimum resolution | 0.1s | ||||||
Accuracy | ±(1% + 50ms) | ||||||
Interface of PLC | Optional | ||||||
Remote control interface | Yes | ||||||
Exterior dimension | 315*285*175mm | 440*380*180 | 430*375*190 | ||||
Weight | 8.76Kg | 9.10Kg | 13.72Kg | 18.2Kg | 24.6Kg |
Items | Model | ZX2671A | ZX2671B | ZX2671C | |||
ACW | Output voltage range | (0.00 ~10.00)kV | |||||
Maximum output power | 200VA(10.0kV/20mA) | 500VA(10.0kV/50mA) | 1000VA(10.0kV/100mA) | ||||
Maximum rated current | 20mA | 50mA | 100mA | ||||
Current taps | 2mA,20mA | 2mA,20mA,50mA | 2mA,20mA,100mA | ||||
Output waveform | Sine wave | ||||||
Output waveform distortion | ≤5%(No-load or pure resistive load) | ||||||
Test time | 0.0s~999s 0.0=continuous test | ||||||
DCW | Output voltage range | (0.00~10.0)kV | |||||
Maximum output power | 100VA(10.0KV/10mA) | 200VA(10.0KV/20mA) | |||||
Maximum rated current | 10mA | 20mA | |||||
Current taps | 2mA,10mA | 2mA,20mA | |||||
Ripple factor | ≤5 % | ||||||
Test time | 0.0s~999s 0.0=continuous test | ||||||
V | Range | (0.00~10.0KV) | |||||
accuracy | ±(5%+3 words) | ||||||
Resolution | 10V | ||||||
Display the value | Root mean square value | ||||||
A | measuring range | AC | 0.100mA~20.0mA | 0.100mA~50mA | 0.100mA~100mA | ||
DC | 0.100mA ~10.0mA | 0.100mA ~20.0mA | |||||
Resolution | 2mA stop:1uA, 20mA stop:10uA,50mA(100mA) stop:0.1mA | ||||||
measurement accuracy | ±(5%+3 words) | ||||||
Time meter | range | 0.0s~999s | |||||
Minimum resolution | 0.1s | ||||||
Accuracy | ±(1% + 50ms) | ||||||
PLC interface | Optional | ||||||
Remote control interface | Yes | ||||||
Exterior dimension | 380*305*195mm | 443*390*220mm | 440*380*180mm | ||||
Weight | 14.76Kg | 25Kg | 18.2Kg |
Items | Model | ZX2674A | |
ACW | Output voltage range | (0.00~20.0)kV | |
Maximum output power | 400VA(20.00kV/20mA ) | ||
Maximum rated current | 20mA | ||
Current stalls | 2mA,20mA | ||
Output waveform | Sine wave | ||
Output waveform distortion | ≤5%(No-load or pure resistive load) | ||
Test time | 0.0s~999s 0.0=continuous test | ||
DCW | Output voltage range | (0.00~20.0)kV | |
Maximum output power | 200VA(20.0kV/10mA) | ||
Maximum rated current | 10mA | ||
Current taps | 2mA,10mA | ||
Ripple factor | ≤5% | ||
Test time | 0.0s~999s 0.0=continuous test | ||
V | Range | (0.00~20.0kV) | |
accuracy | ±(5%+3 words) | ||
Resolution | 10V | ||
Display the value | Root mean square value | ||
A | measuring range | AC | 0.100mA~20.0mA |
DC | 0.100mA~10.0mA | ||
Resolution | 2mA file:1uA,20mA file:10uA | ||
measurement accuracy | ±(5%+3 words) | ||
Time meter | range | 0.0s~999s | |
Minimum resolution | 0.1s | ||
Accuracy | ±(1%+50ms) | ||
PLC interface | Optional | ||
Remote control interface | Optional | ||
Exterior dimension | 450*515*230mm | ||
Weight | 34.9Kg |