Product Details

 Portable Variable Frequency Resonant Withstand Voltage Test Set , For 132KV GIS Test

 

I. Application :


This test set model CHX-275KVA/275KV is designed for 132KV and below class GIS on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 275KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints.

 

Through modular test reactor is used in parallel , the test set model CHX-275KVA/275KV also can be performed the following AC hipot test:

  • No more than 55KV and 5A for medium voltage XLPE cable , scuh as 45KV and below class.
  • No more than 110KV and 2A for medium voltage XLPE cable , scuh as 66KV and below class.
  • No more than 275KV and 1A for medium voltage GIS , scuh as 132KV~170KV and below class.
  • No more than 55KV and 5A for power motor or generator within 45~55Hz 
  • Medium voltage switchgear and power transformer ,scuh as 132KV and below class.

   

Until now , these portable designed  test set can form many different serialized model according to different medium votage withstand test applications through test reactors in series or in parallel connection and number of configurations in each set, The alike model can see other typical model at the following clause.

 
2. Main Components:

 

SNName of ComponentsType and specificationQty.Each weightEach Dimension
1Variable frequency powerFKVF-20kW/380V1piece20kgs440*360*360mm
2Excitation transformerCQSB(J)-15kVA/15KV,3KV1piece50kgs520*350*550mm
3HV resonant test reactorCHX(kf)-55kVA/55kV5pieces60kgsD480*H520mm
4Capacitive dividerTRF-300kV/1000pF1set35kgsD170*H1850mm
5Special test accessories 1set  

 Note:1.Load  capacitantor can be optional when testing power motor ,generator and power transformer under 45~65Hz.

 2.Test reactor can be produced to be 18KV,20KV,22KV,40KV,44KV, 50KV, 54KV,55KV for each piece according to different tested object scope or customer requried.

 

III. Test priciple :

 
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
 
 
V.Test Wiring Schematic Diagram(for example) : 

 
V. General Technical data:

  1. Mode of system test: Series resonant with variable frequency
  2. System model : FKTF-275KVA/275KV
  3. Input power supply : 380±10%(three-phase),50Hz/60Hz
  4. Rated inductance parameter: 55KVA/55KV/1A/200H/each
  5. Number of HV test reactor: 5pieces
  6. Rated output capacity: 275kVA
  7. Rated output Voltage: 275KV
  8. Max Test voltage : no more than 275KV
  9. Rated output current: 1A /single piece or  in series;5A in parallal
  10. Reg. Freq range : 30Hz-300Hz
  11. Output Resonance voltage waveform: sine wave
  12. THD of output waveform: ≤1%
  13. Insulation level: Under 1.1 times and keeping 1min, normal
  14. Duty cycle : 60mins on under rated current working condition ;
  15. Quality factor of test set itself: Q≥30(at F=30HZ) ;
  16. Temperature rise: Less than 65K under rated current working 60mints;
  17. Noise level: No more than 70B
  18. Reactor Structure: dry type, epoxy tube cylinder type;

 
VI. Main Measuring and control software panel:  

 Note: This is the software panel before start test for parameter setting
 

VII .Delivery wooden case packing list

 

Case No.Packed goods nameModel&spec.Goods qty.in the wooden caseWooden case dimension (cm)Case gross weight Case numberRemark
6-1VF power sourceFKVF-20kW1piece55*47*6045kgs1 
6-2Excitation transformerCQSB(J)-15kVA1piece67*51*87110kgs1 
6-3HV reactorsCHX(kf)-55kVA/55kV5pieces141*98*82619kgs1One case packing
Accessories boxIncluding test cables and manual1set
6-4Voltage divider TRF-300kV-1000pF1piece178*57*5180kgs1 
6-5Corona ring for divider ,reactor 1set90*90*9456kgs1One case packing
Supporting base for divider 1piece
6-6Insulation supporting bases for reactor28KV,165KV each one2pieces63*63*12352kgs1 
    Total962kgs6 wooden case 

 
 
VIII.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Insulation supporting base
  • corona ring for 275KV test
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .

 
 IX. Other Optional Model 

 

1. For  GIS on-site  test

ModelRated voltageRated output currentRated output capacity

Application

(From 45Hz starting)

CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
Special requirement can be made by order

 

 

2. For 45KV  XLPE cable on-site test 

ModelRated voltageRated output currentRated output capacityMax Application
CHX-108/5454KV2A108KVA45kV cable≤1km
CHX-216/5454KV4A216KVA45kV cable≤2km
CHX-324/5454KV6A324KVA45kV cable≤3km
CHX-432/5454KV8A432KVA45kV cable≤4km
CHX-540/5454KV10A540KVA45kV cable≤5km
CHX-1080/5454KV20A1080KVA45kV cable≤10km
Special requirement can be made by order

 

3. For 66KV XLPE cable on-site test

ModelRated voltageRated output currentRated output capacityMax Application
CHX-160/8080KV2A160KVA66kV cable≤0.5km
CHX-320/8080KV4A320KVA66kV cable≤1km
CHX-640/8080KV8A640KVA66kV cable≤2km
CHX-960/8080KV12A960KVA66kV cable≤3km
CHX-1280/8080KV16A1280KVA66kV cable≤4km
CHX-1600/8080KV20A1600KVA66kV cable≤5km
CHX-3200/8080KV40A3200KVA66kV cable≤10km
CHX-9600/8080KV120A9600KVA66kV cable≤20km
Special requirement can be made by order

 

 

X. On-site insulation test standard table from IEC62271-203:2011 for GIS

 

XI. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

Hot Products

Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and 110KV Power ...
4. Portable Variable Frequency Resonant Withstand Voltage Test Set , For 132KV GIS Test I. ...
Portable Variable Frequency Resonant Withstand Voltage Test Set , For 10KV and 35KV Cable Test I. ...
Portable Variable Frequency Resonant Withstand Voltage Test Set , For 110KV Powe Substation Test Set ...
Portable Variable Frequency Resonant Withstand Voltage Test Set , For 132KV GIS Test I. Application ...
Variable Frequency AC Resonant Withstand Voltage Test Set , Variable Frequency Resonant Control Unit ...