Home Companies Dewei Medical Equipment Co., Ltd

XN Series Compatible Laboratory Sysmex Hematology Reagents With Closed System Barcode Chip

Dewei Medical Equipment Co., Ltd

Contact Us

Trade Verify

Address: B318 Building B, Western Silicon Valley, Bao'an District, Shenzhen, China

Contact name:Sherry Cai

Inquir Now

Dewei Medical Equipment Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

XN Series Compatible Laboratory Sysmex Hematology Reagents With Closed System Barcode Chip

City & Province shenzhen
Categories Dresses
InquireNow

Product Details

Compatible Use Sysmex Hematology Reaegnts XN Series XN-1000 B1 B2 B3 B4 CBC Analyzer ( with Barcode Chip )

Intended Use? To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XN Series XN-1000 A1 A2 B1 B2 B3 B4, barcode and chips are offered with closed system.

 
Specification?

Compatible Use on XN-1000 Series A1 A2 B1 B2 B3 B4

( with Barcode , Tape chip )

Cat. NoDescriptionPack Size
DWX-50101DILUENT-DCL20L
DWX-50102LYSE-WNR4L*2
DWX-50103DYEWNR82ml*2
DWX-50104LYSE-WDF4L*2
DWX-50105DYEWDF42ml*2
DWX-50106LYSE-SLS1.5L*2
DWX-50107DILUENT-DFL1.5L*2
DWX-50108DYERET12ml*2
DWX-50109AUTOCLEAN-SYS4ml*20
DWX-50110LYSE-WPC1.5L*2
DWX-50111DYEWPC12ml*2
DWX-50112DYEPLT12ml*2


What are our advantages?
1. Experienced R&D with high investment.
2. Strict quality control with international standards.
3. Automated Production line, no defected product is allowed.
4. 24 hour service.
 
Attention of CBC Reagents?
1. If the product freezes, it should be completely defrosted at room temperature and used after mixing.
2. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;
3. This product is an in vitro diagnostic reagent;
4. Pay attention to seal and prevent pollution;
5. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;
6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin, please flush with water immediately and seek medical advice.
 
Limitations of Detection Method?
If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.
 
Storage of Cell Counter Reagents?
The product should be stored in 2℃-38℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.


 

Hot Products

【INTENDED USE】 The Strep A Rapid Test (Swab) is a rapid visual immunoassay for the qualitative, ...
Test kit is created for the qualitative detection and differentiation of Toxoplasma specific IgG and ...
【INTENDED USE】 The Dengue NS1 & IgG/IgM Rapid Test Combo is a rapid chromatographic immunoassay for ...
Disposable Sysmex Hematology Reagents In Vitro Diagnostic high proformance XE-5000 XE-2100 5 diff ...
CBC Reagents Sysmex Hematology Reaegnts SYSMEX 3 Part Analyzer Compatible Reagent Manufacturer ...
CE ISO CFDA approved Hematology Analyzer Reagents XP-100 KX-21(N) 3 Part 3 Diff Sysmex Intended Use ...