The low-noise solenoid controlled relief valve is a
combination of a low-noise type pilot operated relief
valve and a solenoid operated directional valve. It’s designed to
be exchanged with YUKEN S-BSG seriesfor no-load pump operation by
using electric signals or, together with a remote control relief
valve, for two or three pressure control of the hydraulic system.
■ Instructions
●If a remote control relief valve is used in the vent circuit, see
page C-1. In addition, if the internal volume of the vent line is
too large, chattering is likely to occur. Thus, as far as possible
reduce the inside Dia. and the length of the pipe.
●Pressure is limited by collars fitted. If a working pressure
cannot be attained, remove some collars. One collar is
equivalent to 10 MPa (1450 PSI).
● With a small flow, the setting pressure may be unstable. Use
models numbered 03 and 06 with a flow rate above 5 L/min (1.3 U.S.
GPM) and model 10 with 8 L/min (2.1 U.S. GPM).