Home Companies Nanjing Token Electronics Science&Technology Co., Ltd.

PCB Mounting Closed Loop Hall Effect Sensor AC Current Transducer

Nanjing Token Electronics Science&Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN

Contact name:Suki

Inquir Now

Nanjing Token Electronics Science&Technology Co., Ltd.

PCB Mounting Closed Loop Hall Effect Sensor AC Current Transducer

Country/Region china
InquireNow

Product Details

PCB Mounting Closed Loop Hall Effect Sensor AC Current Transducer

 

The TBC-TBH Series current sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.

 

Electrical data(Ta=25℃±5℃)

 

Type

Parameter
TBC300TBHTBC400TBHTBC500TBHUnit

Rated input (Ipn)
12-30016-40020-500A

Measure range(Ip)
900(±24V,33Ω)1200(±24V,24Ω)1500(±24V,12Ω)A


Measure resister

with ±15V

@±300Amax 100(max)@±400Amax 82(max)@±500Amax 75(max)Ω
@±600Amax 27(max)@±800Amax 15(max)@±1000Amax 8.2(max)Ω


Measure resister

with ±18V

@±300Amax 120(max)@±400Amax 110(max)@±500Amax 100(max)Ω
@±900Amax 10(max)@±1200Amax 5.0(max)@±1200Amax 8.2(max)Ω
Turns ratio(Np/Ns)1:30001:40001:5000 
Secondary coil resister405060Ω
Rated output (Isn)@Ip=±Ipn ±100±0.2%FSmA
Supply voltage±15~±24V
Power consumption20+IpX(Np/Ns)mA
Zero offset current@Ip=0 ≤±0.2mA
Offset current drift@ -40℃~85℃ ≤±0.5mA
Response time@100A/μS,10%-90% <1μs
Linearity@Ip=0-±Ipn ≤0.1%FS
Galvanic isolation@ 50HZ,AC,1min 6KV

 

di/dt accurately followed

>100A/μs
Bandwidth@ -3dB DC…100KHz

 

Applications

 

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 

Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm

 

Directions for use

 

Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001

 

  • EN50178:1998
  • SJ 20790-2000

 

General date

 

 ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)329gM

 

Characteristics chart

Pulse current signal response characteristic Effects of impulse noise

Hot Products

50-200A Hall Effect Current Sensor Transducer For Frequency Converter Characteristics chart The TKC...
20-500A Hall Effect Current Sensor Transducer Programming Type Characteristics chart The TKC-TG3 ...
Programming hall sensor TKC-TF512 maily used in BMS of electric vehicle TKC-TF512 series is a kind ...
Wide Range Measurement 4800A Hall Effect sensor for inveter use TKC-GT1540 TKC-GT1540 series is a ...
1000-20000A Open Loop Hall Effect Current Sensor For Frequency Converter Applications Variable speed ...
High Precision Open Loop Hall Effect Current Sensor TKC-EKA Series Dismountable Open Loop Hall ...