Shandong Mgreenbelt Machinery Co.,Ltd |
|
Features of Batch Plant/Concrete Mixing Plant Industrial Water Cooled Chiller
• High/low pressure protection for the compressor and overheating
protection inside the machine
•Low water leve alarm and low water temperature alarm
•Famous brand and durable screw compressor(Hanbell & Bizter)
adopted to ensure the core quality,
•Refrigerating system welded with oxygen free method ,to reduce
oxides and ensure the smooth surface
•Throttle components from ALCO(US)and DANFOSS(Denmark),Emerson(US),
•Stainless plate,coil,sheland tube or fin type efficient heat
ex-changer
•RS485 communication function,to realize automatic
management(optional)
•Electricadevices supplied from OMRON,FUJI.TE.LG.MOELLER,and
SCHNEIDER
•Contromode: imported micro-computer or PLC(optional)
•Perfect safety protection, failure display, and not requiring
professionapersonnefor maintenance
•Highly efficient evaporator and condenser , To save over 30%
energy
•Imported quality parts for serve lives
•Temperature controlled 5℃~ 35℃
•Precision controlled ±1℃
•Can be customized according to customer requirements
Technical Sheet for double compressor water cooled chiller:
Model | MG-60WSD | MG-80WSD | MG-100WSD | MG-120WSD | MG-140WSD | MG-150WSD | MG-170WSD | MG-180WSD | MG-200WSD | MG-220WSD | |
Cooling Capacity | USRT | 50.2 | 68.4 | 89.8 | 97.8 | 119.2 | 130.8 | 154.1 | 162.9 | 178.2 | 192.9 |
Kcal/h | 151876 | 206916 | 271588 | 295668 | 360512 | 395600 | 466120 | 492608 | 539048 | 583424 | |
KW | 176.6 | 240.6 | 315.8 | 343.8 | 419.2 | 460.0 | 542.0 | 572.8 | 626.8 | 678.4 | |
Power Supply | 3PH-380V-50Hz | ||||||||||
Refrigerant | Type | R22/R407c | |||||||||
Control Type | Thermostatic expansion valve | ||||||||||
Comperssor | Type | Semi-closed screw type | |||||||||
Power(kw) | 42.8 | 56.4 | 70.8 | 77.6 | 94.4 | 102.8 | 105.8 | 121.8 | 134.0 | 146.2 | |
Start mode | Y-△ | ||||||||||
Energy stage | 25-50-75-100(%) | ||||||||||
Evaporator | Type | High efficiency copper tube shell and tube type | |||||||||
Water Flow(m³/h ) | 30.3 | 41.2 | 54.1 | 58.9 | 71.9 | 78.9 | 92.9 | 98.2 | 107.5 | 116.3 | |
Inlet/Outlet Dia.(mm) | DN80 | DN100 | DN100 | DN100 | DN125 | DN125 | DN125 | DN150 | DN150 | DN150 | |
Condenser | Type | High efficiency threaded copper tube shell and tube type | |||||||||
Cooling Water Flow(m³/h ) | 41.4 | 56.0 | 72.9 | 79.5 | 96.9 | 106.1 | 122.2 | 131.0 | 143.5 | 155.5 | |
Inlet/Outlet Dia.(mm) | DN80 | DN100 | DN100 | DN100 | DN125 | DN125 | DN125 | DN150 | DN80*2 | DN100*2 | |
Safety Protection | Compressor overheat protection, high/low pressure protection,phase missing/sequence protection, flow rate protection, anti-frozen protection. | ||||||||||
Dimension | L | 2500 | 2500 | 3500 | 3500 | 4000 | 4000 | 4000 | 4000 | 4000 | 4000 |
W | 900 | 900 | 900 | 900 | 900 | 1000 | 1000 | 1000 | 1400 | 1400 | |
H | 1500 | 1500 | 1500 | 1500 | 1500 | 1800 | 1800 | 1800 | 1600 | 1600 | |
Niose | dB | 73.1 | 73.7 | 74.8 | 78.4 | 79.0 | 79.2 | 79.6 | 80.4 | 80.4 | 83.1 |
Net Weight | kg | 1120 | 1300 | 1450 | 1500 | 1700 | 1900 | 2050 | 2150 | 2300 | 2500 |
Note:
Testing working condition:refrigerating medium inlet/outlet temperature 12℃/7℃,Cooling water inlet/outlet temperature 30℃/35℃.
Customise accept for the special working need.
Any specification will be changed based on technical update.
Finished water cooled screw chiller
Complete cooling system schematic for concrete batching plant:
We PROVIDE all the items following, water cooled chiller, coolingand chilled water pumps, and cooling tower
More different series water chillers provide
Information you need to confirm and care
Q1: How to choose the right chiller?
A1:
1).Power supply voltage : PH/ V/ HZ?
2).Refrigerant type R22(Freon ) or CFC free one R407C?
3).What is the cooling capacity requests , KW?
4). What is the outlet water temperature and return water
temperature to chiller?
5). Do you have the requests for the water flow rate , water
pressure and water quality?
6). For what kind of equipment or cooling system( Close loop or
open loop ) in your side?
7). What is the maximum ambient working temperature in your
factory?
Q2: What power supply chiller you can produce?
A2: Our standard power supply is 3phase-380V-50Hz, Customzied
different for optaions, like 3phase- 415V,440V,460V,480V,- 50Hz or
60Hz
Q3:What is your Payment terms?
A3:Standard is 50% in advance to production, the balance before
shippment, this mainly depends on the order.
Q4:What refrigerant you can supply?
A4: We have R22, Eeo friendly R407c, R410a, R134a,R404a depends on
your choice.
Q5:This model and type chiller is not what I need, what should I
do?
A5:Please tell us the Q1, or your further requirements, then the
solution will be sent to your email with prompt.