ACS / AW Short Delivery Aluminum Clad Steel Wire For Electrical Power Cable

Country/Region china
City & Province nanjing jiangsu
Categories Electrical Wires
InquireNow

Product Details

 

(ACS) Aluminum Clad Steel Wires

Construction

Aluminum-clad steel wire, commonly abbreviated as AW or AS or AC, is an electrical conductor composed of an inner steel core and outer Aluminum cladding. Aluminum clad steel wire is a bimetallic in which aluminum covers on the steel core continuously and evenly.

Advantages

Aluminum-clad steel wire is superior to galvanized or aluminized steel in every way.

● Better corrosion resistance due to thick EC-grade aluminum covering

● Wider range of combinations of tensile strength and conductivity

● Lighter weight

● Excellent thermal stability

● Wider variety of products, with broad range of properties, quality, and size of steel wire and aluminum cladding.

● Compared with ordinary aluminum conductor steel reinforced, the conductor weight is 5% lighter, current-carrying capacity is 2-3% higher and power loss decreases 4-6%. Thus, the service life is long and it adds none erection cost.

 

Application

The aluminum clad steel wire is widely used in long-span transmission line, coastal areas and island as well as other hot and humid regions, salt fog regions and heavily polluted regions where the high corrosion resistance strand is needed.

 

It is used as the core of ACSR/AW, overhead ground conductor, extra high voltage overhead conductor, optical fiber composite overhead ground line, self-damping conductor line, bare overhead conductor, OPGW, ground wire, messenger wire, guy wire formed wire for protecting, terminating and splicing transmission and distribution lines, fence, barber wire and hardware, etc.

 

Standards

IEC 61232, ASTM B415, ASTM B502, AS 3607 and other International Standards.

However, can also supply a range of alternative designs with customized solutions to meet customer requirements.

Abbreviations

AW : Aluminum-clad steel wire as per ASTM B 502 Standard.

AS : Aluminum-clad steel wire as per IEC 61232 Standard.

AC : Aluminum-clad steel wire as per AS 3607 Standard.

 

Classification of Aluminum Clad Steel wire

 

Clas

14%

IACS

20.3%

IACS A

20.3%

IACS B

23%

IACS

27%

IACS

30%

IACS

35%

IACS

40%

IACS

Sectional Ratio of Al (%)

1325253037435262

Sectional Ratio of St (%)

8775757063574838

Weight Ratio of AL (%)

510.410.412.916.920.727.336.1

Weight Ratio of ST (%)

9589.689.687.183.179.372.763.9

 

Physical Constants

 

Class

14%

IACS

20.3%

IACS A

20.3%

IACS B

23%

IACS

27%

IACS

30%

IACS

35%

IACS

40%

IACS

Nominal Density at 20°C (g/cm3 )7.14

6.59

 

6.59

6.27

 

5.91

 

5.61

 

5.154.64
Final Modulus of Elasticity (Gpa)170

162

 

155

149

 

63

132

 

122

 

109
Coefficient of Linear Exp. (per °C)12 x 10-6

13 x 10-6

 

12.6 x 10-612.9x10-613.4 x 10-6

13.8 x10-6

 

14.5 x 10-6

 

15.5 x 10-6

 

Temperature coefficient (per °C)

0.0034

 

0.0036

 

0.0036

 

0.0036

 

0.0036

0.0038

 

0.0039

 

0.004

 

% Elongation at Fracture on 250mm

1.5

 

1.51.51.51.51.51.51.5
 The design of an aluminum-clad steel wire with a specified conductivity is based on 61 % IACS of aluminum and 9 % IACS of steel. For example, the conductivity of 30% IACS is dealt with as follows: Designed conductivity: Aluminum (61 % IACS x 0.43) + Steel (9 % IACS x 0.57) = 31.36 % IACS. Then, taking into consideration allowances, minimum conductivity is specified as 30 % IACS (57.47 nΩm). When only the aluminum covering is taken into account as the conductive part in the conductor, the electrical resistance of aluminum-clad steel wires can be calculated by the cross-sectional area of aluminum as per above and the conductivity of 61 % IACS.

Specifications for Aluminum Clad Steel Wires (Before Stranding)

 

ClassType

Nominal Diameter

(mm)

Min Tensile Strength (MPa)

 

Min stress at 1 % elongation (MPa)

 

Max. Resistivity at Over 20°C (nΩ∙m)

 

 

 

 

 

14%1ACS

 

over

Upto & Including

 

    A1.243.015901410                      123.5
3.03.515501380
3.54.7515201380
4.755.514001200
    B2.14.017701550

 

 

 

 

20%1ACS

 

 1.243.2513401200

84.80

3.253.4513101180
3.453.6512701140
3.653.9512501100
3.954.112101100
4.14.411801070
4.44.611401030
    B4.64.7511001000
23%1ACS 2.505.001220980                         74.96
27%1ACS 2.505.001080800                         63.86
30%1ACS 2.505.00880650                         57.47

35%1ACS

 

    A2.505.00810590

49.26

 

    B2.505.00880650

40%1ACS

 

    A2.505.00680500                         43.10
    B2.505.00750550

SINGLE WIRE AS PER ASTM B 415 STANDARD

Size

AWG

 

Diameter

 

Tensile

Strength

 

Cross

section

 

D C Resistance

at 20°C

 

Nominal

Weight

 

Minimum Thickness of Aluminum Cladding

 

in.mm

ksi

 

N/mm²

 

in²

 

mm²

 

Ω/km

 

lb/1000 ft

 

Kg/km

 

in

 

mm

 

( CONDUCTIVITY = 20.3 % IACS)
4.00.2045.18915510700.0327821.1494.01093.67139.370.010220.259
0.1884.77516011000.0277617.9094.73579.32118.020.009400.239
5.00.1824.62016511400.0259916.7665.05874.25110.490.009100.231
0.1734.39217011700.0234815.1485.59867.0999.820.008650.220

6.0

 

0.1624.11517512100.0206113.2986.37758.8987.630.008100.206
0.1553.93418012400.0188412.1586.97553.8480.120.007750.197
7.00.1443.66518512800.0163510.5518.03746.7369.530.007220.183
0.1373.47719013100.014729.4978.93042.0662.580.006850.174
8.00.1293.26419513400.012978.36710.13537.0655.140.006430.163
9.00.1142.90619513400.010286.63112.78729.3743.700.005720.145
10.00.1022.58819513400.008165.26116.11723.3034.670.00510.129
11.00.0912.30419513400.006464.16820.34318.4627.470.004540.115
12.00.0812.05219513400.005133.30825.63414.6521.800.004040.103
CONDUCTIVITY = 27 % IACS)
4.00.2045.1891258620.0327821.1493.01984.00124.990.014300.363
0.1884.7751067310.0277617.9093.20967.52100.470.014100.358
5.00.1824.6201107580.0259916.7663.42863.2194.060.013640.347
0.1734.3921147860.0234815.1483.79457.1184.980.012970.329
6.00.1624.1151147860.0206113.2984.32250.1474.600.012150.309
0.1553.9341188140.0188412.1584.72745.8468.210.011620.295
7.00.1443.6651228410.0163510.551 55.44739.7859.190.010820.275
0.1373.4771268690.014729.4976.05235.8053.280.010270.261
8.00.1293.26415610760.012978.3677.63233.2349.450.009000.228
9.00.1142.90615610760.010286.6319.62926.3439.190.008010.203
10.00.1022.58815610760.008165.26112.13620.9031.100.007130.181
11.00.0912.30415610760.006464.16815.31916.5624.640.006350.161
12.00.0812.05215610760.005133.30819.30313.1419.550.005660.144
( CONDUCTIVITY = 30 % IACS)

 

4.0

0.2045.1891027030.0327821.1492.71779.74118.650.015320.389
0.1884.7751067310.0277617.9093.20967.52100.470.014100.358
5.00.1824.6201107580.0259916.7663.42863.2194.060.013640.347
0.1734.3921147860.0234815.1483.79457.1184.980.012970.329
6.00.1624.1151147860.0206113.2984.32250.1474.600.012150.309
0.1553.9341188140.0188412.1584.72745.8468.210.011620.295
7.00.1443.6651228410.0163510.5515.44739.7859.190.010820.275
0.1373.4771268690.014729.4976.05235.8053.280.010270.261
8.00.1293.2641288830.012978.3676.86931.5446.940.009640.245
9.00.1142.9061288830.010286.6318.66625.0037.200.008580.218
10.00.1022.5881288830.008165.26110.92319.8429.520.007640.194
11.00.0912.3041288830.006464.16813.78715.7223.380.006800.173
12.00.0812.0521288830.005133.30817.37212.4718.560.006060.154
( CONDUCTIVITY = 40 % IACS)

 

4.0

0.2045.189805520.0327821.1492.03865.9598.130.025540.649
0.1884.775845790.0277617.9092.40755.8583.100.023500.597
5.00.1824.620886070.0259916.7662.57152.2877.790.022740.578
0.1734.392926340.0234815.1482.84547.2370.290.021610.549
6.00.1624.115966620.0206113.2983.24141.4761.700.020250.514
7.00.1443.665986760.0163510.5514.08532.9048.960.018040.458
0.1373.477986760.014729.4974.53929.6144.060.017110.435
8.00.1293.26499.56860.012978.3675.15226.0938.820.016060.408
9.00.1142.90699.56860.010286.6316.50020.6830.770.014300.363
10.00.1022.58899.56860.008165.2618.19216.4124.410.012740.324
11.00.0912.30499.56860.006464.16810.34013.0019.340.011340.288
12.00.0812.05299.56860.005133.30813.02910.3215.350.010100.257

SINGLE WIRE AS PER ASTM B 502 STANDARD

 

DiameterTensile StrengthStress at 1% ExtensionResistityDensity
in.mmksiN/mm2ksiN/mm2    
0.0770 ~ 0.12891.956 ~ 3.27419513441751206

 

 

 

51.01

 

 

 

84.8

 

 

 

0.2381

 

 

 

6.59

0.1290 ~ 0.13693.275 ~ 3.47719013101701172
0.1370 ~ 0.14433.478 ~ 3.66518512751651137
0.1444 ~ 0.15493.666 ~ 3.93418012411601103
0.1550 ~ 0.16203.935 ~ 4.11517512061601103
0.1621 ~ 0.17294.116 ~ 4.39217011721551068
0.1730 ~ 0.18194.393 ~ 4.62016511371501034
0.1820 ~ 0.18804.621 ~ 4.77516011031451000
Coefficient of linear expansion Modulus of Elasticity

: 12.6 x 10-6 /°C

: 23500 Ksi (162000 MPa)

Temperature coefficient of Resistance: 0.0036/°C

Minimum Aluminum Thickness : 10% of nominal wire radius

 

SINGLE WIRE AS PER AS-3607 STANDARD

Diameter(mm)Tensile StrengthCross section

D.C Resistance

at 20℃

 

Nomial weight

Min.thickness of

Aluminum cladding

standardmax.min.N/mm2KNmm2

Ω/km

 

kg/kminmm
1.6001.6401.56013402.692.01142.2813.250.080 
1.7501.7901.71013403.222.40535.3415.850.088 
2.2502.2902.21013405.333.97621.3826.200.113 
2.5002.5402.46013406.584.90917.3232.350.125 
2.7502.7912.70913407.965.94014.3139.140.138 
3.0003.0452.95513409.477.06912.0346.580.150 
3.2503.2993.201134011.128.29610.2554.670.163 
3.5003.5533.448131012.609.6218.8363.400.175 
3.7503.8063.694127014.0311.0457.7072.780.188 
Coefficient of linear expansion Modulus of Elasticity

: 12.9 x 10-6 /°C

: 23500 Ksi (162000 MPa)

Temperature coefficient of Resistance: 0.0036/°C

Minimum Aluminum Thickness : 10% of nominal wire radius

 

 

Hot Products

galvanized guy wire/static wire used for Messenger Wire, Overhead Ground or Static Wire, Guy Wire. ...
Galvanized Steel Wire Strand 7/10 SWG Description Stay Wires are galvanized steel wire strands that ...
Galvanized Steel Wire Strand 7/10 SWG Description Stay Wires are galvanized steel wire strands that ...
Galvanized Steel Wire Strand 7/16 SWG Description Stay Wires are galvanized steel wire strands that ...
Galvanized Steel Wire Strand 7/8 SWG Description Stay Wires are galvanized steel wire strands that ...
1/8" EHS 7 wires Galvanized Steel Wire Strand as per ASTM A 475 Discriptions Galvanized guy wire ...