IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
standard
ISO 9001 certificate
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power
transmission lines with various voltage levels.
Since they have such good characteristics as simple structure,
convenient installation and maintenance, low cost for the line,
large transmission capacity and are also suitable for laying across
rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor
steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum
conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Relative manufacturing standards: IEC83, IEC1089, 31, B232,
BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS
EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded
galvanized steel wire(s) with aluminum wires surrounded by one or
more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power
transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel
Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II,
IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized
standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231,
CSA C49, DIN480201, JIS C3109, customer special specification also
can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical
distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and
secondary distribution cable. ACSR offers optimal strength for line
design. Variable steel core stranding enables desired strength to
be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a
steel core. Core wire for ACSR is available with class A, B, or C
galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad
(AW). Additional corrosion protection is available through the
application of grease to the corrosion or infusion of the complete
cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM
specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel
Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel
Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel
Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for
Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of
stranding and metal conductivity of 61.2% IACS for EC (1350) and 8%
IACS for steel. AC (60Hz) resistance includes current dependent
hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC
ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of
emissivity and absorption.
Packing:
Standard export wooden drums