1350GF4 50Hz / 60Hz 3 Phase HFO Fired Power Plant For Mining Or Oil


Descrition:


Utilities and Independent power producers use our 0~60 MW power plants to generate power to the grids in the undeveloped, developing world and in remote areas. These plants are flexible to follow the actual load and produce the necessary electricity typically from diesel oil, heavy fuel oil, bio diesel and bi-fuel. High efficiency, low emissions and proven long-term reliability make our diesel oil power plants, heavy fuel oil power plant, and bi-fuel power plants suitable for baseload applications. Depending on your current load profile, ambient conditions and what fuel is available (diesel oil, heavy fuel oil, crude oil etc.) we make sure you will get the most productive and cost-effective solution

Our company offers a wide range of engines for stationary power generation, where their competitive first-cost, high energy efficiencies and low life-cycle costs underwrite success, ranges from baseload power plant, peaking power plant to industrial self-captive power plant in cement, textile, mining or oil and gas industries etc.

These engines comfortably meet current emission standards, and are able to comply with more strict national codes by adding emission reduction equipment.


Peaking power plant


Our power plants can start and ramp up to full load very rapidly, in less than minutes. They can start upon a grid or a large power plant after shut down, without any external input of energy. Due to very high simple cycle efficiency on part and full load, they can provide very competitive power regulation and spinning reserve services to large grids, which both require operation on partial load. These very same plants can be used for peaking services during peak electricity demand hours. Due to the high efficiencies and consequential low generation costs, our power plants create more revenues for its operators. The main fuel can be gas, LFO, HFO or a multi-fuel combination of these.


Industrial self-captive power plant


Many energy intensive industries find it attractive to improve their competitiveness by producing their energy in a local captive power plant and thereby reduce the energy costs. In some areas this improves also the availability of energy due to unstable grid conditions. Many of the industrial power plants operate, producing electricity and utilizing the waste heat of the generation process to produce steam, hot water and cooling. All this we can do for you.


Applications:


cement, textile, mining or oil and gas industries etc.


Competitive Advantage:


Our experts in application engineering and project management are the key to achieving very short construction times , builds turn-key power plant with an output up to 60MW as base load power plant, peaking power plant or industrial self-captive power plant in cement, textile, mining or oil and gas industries etc. The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel


G300 Statinary Generating Sets Main Specification

Model

1000GF1

1250GF3

1350GF4

1400GF4

Rated power, KW

1000

1250

1350

1400

Overload , KW

1100

1375

1485

1540

Rated voltage, V

400/415/440/3300/6300/10500/13800

Rated current , A

 

 

 

 

 

   

Frequency , Hz

50

60

50

60

50

605060

Power factor

0.8 Lagging

Phase

3

Diesel engine

G6300ZD6

G6300ZD8

G8300ZD6

G6300ZD10

G8300ZD10

G8300ZD8G8300ZD10G8300ZD8

Rated power, KW

1103

1470

1471

1471

1765

200017652000

Rated rev, rpm

500

600

500

600

500

600500600

Alternator

3 phase alternator

voltage fluctuation rate%

<0.5

<0.5

Frequency fluctuation rate, %

<0.5

<0.5

Stable voltage regulating rate, %

±1.0

±1.0

Transient voltage regulating rate, %

+20, -15

+20, -15

Stable Frequency fluctuation rate, %

<3

<0.5

Transient frequency regulating rate, %

+12, -10

Stablizing time, voltage , S

<4

Stablizing time, frequency , S

<3

voltage regulating method

automatic and munual

Frequency regulating method

manual

starting method

compressed air

Lubricating method

pressue lubricating

Cooking method

water cooling

coupling

flexible

Overdimension, mm

3880*2150*3180

8470*2360*3060

Weight, Kg

30000

35000

38000

G300 Statinary Generating Sets Main Specification
1500GF61600GF51800GF72000GF8
1500160018002000
1650176019802200
400/415/440/3300/6300/10500/13800
        
5060506050605060
0.8 Lagging
3
G8300ZD10G8300ZD8G8300ZD10G8300ZD8G8300ZD8G8300ZD8G8300ZD12G8300ZD8
17652000176520002000200022062000
500600500600600600600600
3 phase alternator
<0.5
<0.5
±1.0
20, -15
<0.5
+20, -15
<5
<4
automatic and munual
manual
compressed air
pressue lubricating
water cooling
flexible
8470*2360*3060
3800042560


Remark

1.the generator voltage and frequency can be selected

2.rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure 100kpa

charge air coolant temperature 25℃

relative humidity 30%

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position


GN8320 Stationary Generating Sets Main Specification

Model

2400GF

2500GF

Rated power, KW

2400

2500

Overload , KW

2640

2750

Rated voltage, V

400

415

3300

6300

10500

400

415

3300

6300

10500

Rated current , A

4330

4174

525

275

165

4511

4348

547

172

286

Frequency , Hz

50

50

Power factor

0.8 Lagging

0.8 Lagging

Phase

3

3

Diesel engine

GN832000ZD

GN8320ZD

Rated power, KW

2648

2795

Rated rev, rpm

750

750

Alternator

3 phase alternator

voltage fluctuation rate%

±1.0

Frequency fluctuation rate, %

+12, -10

Stable voltage regulating rate, %

3

Transient voltage regulating rate, %

+12, -10

Stable Frequency fluctuation rate, %

4

Transient frequency regulating rate, %

5

Stabilizing time, voltage , S

+1

Stabilizing time, frequency , S

+12, -10

voltage regulating method

automatic and manual

Frequency regulating method

manual

starting method

compressed air

Lubricating method

pressure lubricating

Cooking method

water cooling

coupling

flexible

Overdimension, mm

8950*2570*6050

Weight, Kg

45000


Remark


1.the generator voltage and frequency can be selected

2.rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure

charge air coolant temperature

relative humidity

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position

Hot Products

Technical specificaiton for Power plant equipments Ⅰ. Gen-set technical specification No. Item Unit ...
-- Detailed Product Description(GENSET POWER PLANT) 1. Being in the decentralized energy sector ...
G300 Statinary Generating Sets Main Specification Model 1000GF1 1250GF3 1350GF4 1400GF4 Rated power, ...
Automatic / Munual 2000GF8 HFO Power Plant 3 Ph 500 Rpm / 600 Rpm Descrition: These plants are ...
1350GF4 50Hz / 60Hz 3 Phase HFO Fired Power Plant For Mining Or Oil Descrition: Utilities and ...
Water Cooling Generating Sets HFO Fired Power Plant With G8300 11KV / 750Rpm Descrition: These ...