Home Companies Guangdong ALI Testing Equipment Co,.Ltd

4 Stroke 80 kW Diesel Generator , JPP100E , 100 kva , 4 Stroke

Guangdong ALI Testing Equipment Co,.Ltd
Active Member

Contact Us

[China] country

Address: No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China

Contact name:Kris

Inquir Now

Guangdong ALI Testing Equipment Co,.Ltd

4 Stroke 80 kW Diesel Generator , JPP100E , 100 kva , 4 Stroke

Country/Region china
City & Province dongguan guangdong
Categories Diesel Generators
InquireNow

Product Details

 

1, Generating Set Model:  JPP100E

2, Engine Make & Model:Perkins 1006TG1A

3,Alternator Model:LL3014B

3, Circuit Breaker Type:3 Pole MCB / 3 Pole MCCB

4, Frequency:50 Hz / 60 Hz

5,Cycle:  4 Stroke

6, Engine Speed:1800 rpm

7, Cooling Method:  Water

8, Governing Type:  Electronic

9, Output Type: AC Three Phase

10,Base Frame Type:Heavy Duty FabriCAT-parts-partsed Steel

 

Output Ratings

Generating Set Model

JPP100E Prime                 Standby

380-415V, 50 Hz

      90.0 kVA                           100.0 kVA

       72.0 kW                             80.0 kW

480V, 60 Hz

     110.0 kVA                          120.0 kVA

       88.0 kW                             96.0 kW

  • Refer to ratings definitions on page 4.

      Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 1006TG1A

Alternator Model:

LL3014B

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCB / 3 Pole MCCB

Frequency:

     50 Hz                  60 Hz

Engine Speed: RPM

    1500                    1800

Fuel Tank Capacity: litres (US gal)

     230 (60.8)

Fuel Consumption:    P90       l/hr (US gal/hr)

       20.7 (5.5)            26.1 (6.9)

Fuel Consumption:  P100E       l/hr (US gal/hr)

        23.1 (6.1)            28.3 (7.5)

P90 / P100E

 

 

Engine Technical Data

 

Physical Data

 

Manufacturer:                                                               Perkins

Model:                                                                         1006TG1A

No. of Cylinders/Alignment:                                    6 / In Line

Cycle:                                                                           4 Stroke

Induction:                                                               Turbocharged

Cooling Method:                                                          Water

Governing Type:                                          Mechanical Governing

Class:                                                                      ISO 8528 G2

Compression Ratio:                                                  16.0:1

Displacement: l (cu.in)                                         6.0 (365.5)

Bore/Stroke: mm (in)                                  100.0 (3.9)/127.0 (5.0)

Moment of Inertia: kg m² (lb. in²)                       1.61 (5502)

Engine Electrical System:

-Voltage/Ground:                                                  12/Negative

-Battery Charger Amps:                                               55

Weight: kg (lb) - Dry:                                            586 (1292)

- Wet:                                                                      623 (1373)

 

 

Air System 

 

Air Filter Type:                                       Replaceable Element

Combustion Air Flow:m³/min (cfm)       

-Standby:                                                                                       5.6 (198)                             7.9 (279)

-Prime:                                                                                             5.2 (184)                              7.5 (265)

Max. Combustion Air Intake Restriction: kPa (in H2O)          5.0 (20.1)                             5.0 (20.1)

Radiator Cooling Air Flow:m³/min (cfm)    

                                                                                                    192.0 (6780)                      244.0 (8617)

External Restriction to Cooling Air Flow: Pa (in H2O)           125 (0.5)                             125 (0.5)

 

 

Cooling System                                                                            50 Hz                                       60 Hz

 

Cooling System Capacity:l (US gal)                                        27.7 (7.3)                                  27.7 (7.3)

Water Pump Type:                                                                                              Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                                                                   61.4 (3492)                               76.4 (4345)

-Prime:                                                                                       54.4 (3094)                               69.1 (3930)

Heat Radiation to Room:kW (Btu/min)       

-Standby:                                                                                   39.9 (2269)                               39.7 (2258)

-Prime:                                                                                      32.4 (1843)                                31.0 (1763)

Radiator Fan Load: kW (hp)                                                       2.8 (3.8)                                      4.9 (6.6)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Contact your local FG Wilson dealer for power ratings at specific site conditions.

 

 

Performance                                                                               50 Hz                                              60 Hz

 

Engine Speed: RPM                                                                   1500                                               1800

Gross Engine Power: kW (hp)

 

-Standby:                                                                                96.0 (129.0)                                113.0 (152.0)

-Prime:                                                                                    87.0 (117.0)                                102.7 (138.0)

BMEP: kPa (psi)

-Standby:                                                                            1283.0 (186.1)                              1259.0 (182.6)

-Prime:                                                                                1163.0 (168.7)                              1144.0 (165.9)

Regenerative Power: kW                                                         12.6                                                   16.2

 

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                                                                           Spin-On, Full Flow

Total Oil Capacity l (US gal):                                                                         16.1 (4.3)

Oil Pan l (US gal):                                                                                           13.1 (3.5)

Oil Type:                                                                                                      AP1CD 15W-40

Cooling Method:                                                                                                Water

 

 

Fuel System

 

Fuel Filter Type:                                                                                   Replaceable Element

Recommended Fuel:                                                                             Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110%              100%               75%                50% Load               Load               Load               Load

P90

50 Hz  23.1 (6.1)        20.7 (5.5)        15.7 (4.1)        11.1 (2.9)

 

60 Hz  28.3 (7.5)        26.1 (6.9)        20.0 (5.3)        14.4 (3.8)

 

P100E

50 Hz    23.1 (6.1)        17.3 (4.6)        12.1 (3.2)

60 Hz    28.3 (7.5)        21.6 (5.7)        15.4 (4.1)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

 

Exhaust System                                                                              50 Hz                                               60 Hz

 

Silencer Type: Level 1

Silencer Model & Qty:   SD80 (1)

Pressure Drop Across Silencer System: kPa (in Hg)         0.00 (0.000)                                   0.00 (0.000)

Silencer Noise Reduction Level: dB                                             18                                                        18

Max. Allowable Back Pressure: kPa (in. Hg)                           6.0 (1.8)                                             6.0 (1.8)

Exhaust Gas Flow:

m³/min (cfm)       

-Standby:                                                                                     16.8 (593)                                          22.5 (795)

-Prime:                                                                                         14.9 (526)                                          20.9 (738)

Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                                                                    584 (1083)                                         569 (1057)

-Prime:                                                                                        546 (1014)                                         538 (1001)

P90 / P100E

 

Alternator Performance Data

 

 

 

Data Item

50 Hz                                                            60 Hz

415/

240V

400/230V

230/115V

200/115V

380/220V

220/110V

220

/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/

115V

440/254V

220/127V

 

 

Motor Starting Capability* kVA

 

 

187

 

 

176

 

 

160

 

 

208

 

 

206

 

 

136

 

 

 

160

 

 

149

 

 

177

Short Circuit Capacity** %

300

300

300

300

300

300

300

300

300

Reactances: Per Unit

Xd X'd X''d

 

2.880

0.110

0.067

 

3.100

0.120

0.072

 

3.430

0.130

0.080

 

2.560

0.100

0.060

 

3.150

0.120

0.073

 

5.030

0.200

0.117

 

4.200

0.160

0.098

 

4.540

0.180

0.106

 

3.750

0.150

0.087

 

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

 

Alternator Technical Data

 

Physical Data                                                                                                        Operating Data

Manufacturer:  FG WILSON

Overspeed: RPM 2250

Model:  LL3014B

Voltage Regulation (steady state) (%):    + /- 0.5

No. of Bearings:   1

Wave Form NEMA = TIF: 50

Insulation Class: H

Wave Form IEC = THF: 2.0%

Winding Pitch Code:2/3 - 6

Total Harmonic Content LL/LN: 4.0%

Wires:  12

Supression is in line with European Standard

Radio Interference:       EN61000-6

Ingress Protection Rating:  IP23

Radiant Heat: kW (Btu/min)

-50 Hz:                                    9.0 (512)

-60 Hz:                                   11.1 (631)

Excitation System:  SHUNT

AVR Model:  R230

P90 / P100E

 

 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz, 1500 RPM


3 Phase Ratings and Performance at 60 Hz, 1800 RPM

 


 

 

Voltage         Prime Model                Standby Model          Voltage          Prime Model                Standby Model

P90                            P100E                                          P90                            P100E

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

90.0                72.0

100.0               80.0

480/277V

110.0               88.0

120.0               96.0

400/230V

90.0                72.0

100.0               80.0

220/127V

110.0               88.0

120.0               96.0

380/220V

90.0                72.0

100.0               80.0

380/220V

110.0               88.0

120.0               96.0

230/115V

90.0                72.0

100.0               80.0

240/120V

110.0               88.0

120.0               96.0

220/127V

90.0                72.0

100.0               80.0

230/115V

110.0               88.0

120.0               96.0

220/110V

90.0                72.0

100.0               80.0

440/254V

110.0               88.0

120.0               96.0

200/115V

90.0                72.0

100.0               80.0

220/110V

110.0               88.0

120.0               96.0

 

 

 

208/120V

110.0               88.0

120.0               96.0

 

 

 

230/115V

110.0               88.0

120.0               96.0

 

 

Definitions

Standby Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).



Prime Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.



Standard Reference Conditions

 

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 


 

 

 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in)

 

 

Net (+ lube oil)

 

1240 (2734)

 

Length

 

2481 (97.7)

Wet (+ lube oil & coolant)

1260 (2778)

Width

746 (29.4)

Fuel, lube oil & coolant

1454 (3206)

Height

1435 (56.5)

 

 

General Data

 

Documents

 

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



Generating Set Standards

 

The equipment meets the following standards:

 

Warranty

 

All equipment carries full manufacturer's warranty.

 

Hot Products

1, Generating Set Model:P250HE 2, Engine Make & Model:Perkins 1306-E87TA300 3,Alternator Model...
1, Generating Set Model: P175HE 2, Engine Make & Model:Perkins 1306-E87T215 3, Alternator Model...
1, Generating Set Model: JPP150E 2, Engine Make & Model:Perkins 1006TAG 3, Alternator Model:LL3014F ...
1, Generating Set Model: JPP100E 2, Engine Make & Model:Perkins 1006TG1A 3,Alternator Model:LL3014B ...
1, Engine Make & Model:Perkins 1006TAG 2, Alternator Model:LL3014F 3, Circuit Breaker Type:3 Pole ...
1, Brand Name :CAT-parts-parts Olympian 2, Circuit Breaker Type:3 Pole MCCB 3, Cycle: 4 Stroke 4, ...